Improved Damper Cage Design for Salient-Pole Synchronous Generators

被引:44
|
作者
Nuzzo, Stefano [1 ]
Degano, Michele [1 ]
Galea, Michael [1 ]
Gerada, Chris [1 ]
Gerada, David [1 ]
Brown, Neil [2 ]
机构
[1] Univ Nottingham, Dept Elect Engn, Power Elect Machines & Control Grp, Nottingham NG7 2RD, England
[2] Cummins Power Generat, Peterborough PE1 5EL, Cambs, England
基金
英国工程与自然科学研究理事会;
关键词
Asymmetric rotor winding; damper cage design; harmonic analysis; iron losses calculation; principal inductance; salient-pole synchronous generator; REDUCTION; MACHINES; LOSSES;
D O I
10.1109/TIE.2016.2619321
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The benefits of implementing a damper winding in salient-pole synchronous generators are widely known and well consolidated. It is also well known that such a winding incurs extra losses in the machine due to a number of reasons. In order to improve the overall efficiency and performance of classical salient-pole, wound field synchronous generators that employ the traditional damper cage, an improved amortisseur winding topology that reduces the inherent loss is proposed and investigated in this paper. This is essential in order to meet modern power quality requirements and to improve the overall performance of such "classical" machines. The new topology addresses the requirements for lower loss components without compromising the acceptable values of the output voltage total harmonic distortion and achieves this by having a modulated damper bar pitch. As vessel for studying the proposed concept, a 4-MVA salient-pole synchronous generator is considered. A finite element model of this machine is first built and then validated against experimental results. The validated model is then used to investigate the proposed concept with an optimal solution being achieved via the implementation of a genetic algorithm optimization tool. Finally, the performance of the optimized machine is compared to the original design both at a steady state and transient operating conditions.
引用
收藏
页码:1958 / 1970
页数:13
相关论文
共 50 条
  • [41] Prediction of the Voltage Drop due to the Diode Commutation Process in the Excitation System of Salient-Pole Synchronous Generators
    Nuzzo, S.
    Galea, M.
    Gerada, C.
    Brown, N. L.
    2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [42] CALCULATION OF LOOP PARAMETERS OF SALIENT-POLE SYNCHRONOUS MACHINES.
    Wang, Xiangheng
    Gao, Jingde
    Jin, Qimei
    Ching Hua Ta Hsueh Hsueh Pao/ Journal of Ching Hua University, 1987, 27 (01): : 9 - 19
  • [43] DIFFERENTIAL-EQUATIONS OF A SATURATED SALIENT-POLE SYNCHRONOUS MACHINE
    CHABAN, VI
    ELECTRICAL TECHNOLOGY, 1976, (04): : 30 - 37
  • [45] CALCULATING THE MAGNETIC FIELD OF A SYNCHRONOUS SALIENT-POLE MACHINE.
    Afanas'ev, A.A.
    Pupin, V.M.
    1600, (21):
  • [46] Spiral vector theory applied to salient-pole synchronous machine
    Touhami, O
    Menaa, M
    Ibtiouen, R
    Benhaddadi, M
    SYSTEM STRUCTURE AND CONTROL 1997, 1998, : 499 - 504
  • [47] MATHEMATICAL MODEL OF A SATURATED SALIENT-POLE SYNCHRONOUS MACHINE.
    Chaban, V.I.
    Pavlyna, V.F.
    Power engineering New York, 1981, 19 (02): : 65 - 73
  • [48] Modeling of salient-pole synchronous motor considering saturation effect
    Jing, Wei
    Tan, Guo-Jun
    Ye, Zong-Bin
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2010, 14 (10): : 94 - 99
  • [49] Analysis of Damper Transient Currents in Salient-Pole Synchronous Generator With Skewed Armature Slots Considering Interbar Currents
    Zhan, Yang
    Kong, Kangkang
    Xu, Guorui
    Kang, Jinping
    Zhao, Haisen
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (01) : 336 - 343
  • [50] ON PROPERTIES OF SALIENT-POLE SYNCHRONOUS MACHINE FIELD SPATIAL HARMONICS
    ARUTYUNYAN, VS
    ELECTRICAL TECHNOLOGY, 1982, (03): : 59 - 71