The Effect of Different Fire Source Locations on the Environment of a Subway Station

被引:5
|
作者
Lei, Wenjun [1 ,2 ]
Li, Angui [3 ]
Tai, Chuanmin [4 ]
机构
[1] Shandong Jianzhu Univ, Dept Bldg Environm & Energy ApplicationEngn, Jinan 250101, Shandong, Peoples R China
[2] Shandong Jianzhu Univ, State Minist Educ, Key Lab Renewable Energy Utilizat Technol Bldg, Jinan 250101, Shandong, Peoples R China
[3] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi, Peoples R China
[4] Shandong Jianzhu Univ, Architecture & Urban Planning Design Inst, Jinan 250101, Shandong, Peoples R China
关键词
Subway station; Fire source location; Temperature; Visibility; Carbon monoxide concentration; SMOKE; SIMULATION;
D O I
10.1016/j.proeng.2017.10.305
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effect of different fire source locations on the environment of a subway station was investigated in this paper. Visibility, temperature and carbon monoxide at the evacuation stairs in the subway station were computed by Fire Dynamics Simulator (FDS). Different fire source locations have different evacuation features. Fire source 2 and 3 have the most negative effect on evacuation. Therefore, relevant departments should take some measures to avoid fires breaking out in these places. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:3721 / 3726
页数:6
相关论文
共 50 条
  • [41] Effect Analysis of Different Exhaust Velocity on Fire Smoke Control in Subway Tunnel
    Han, Xin
    Gao, Xiaoming
    Cong, Beihua
    ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 1224 - +
  • [42] Fire Hazard Analysis on Different Fire Source Locations in Multi-Segment Converging Tunnel with Structural Beams
    Wei, Lixin
    Tang, Honghui
    Zhao, Jiaming
    Chen, Shiyi
    Xie, Yiqiang
    Feng, Shilin
    Xu, Zhisheng
    Yu, Zihan
    FIRE-SWITZERLAND, 2023, 6 (11):
  • [43] Simulation on fire emergency evacuation in special subway station based on Pathfinder
    Qin, Jiawen
    Liu, Changcheng
    Huang, Que
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
  • [44] Dynamic evacuation path planning for subway station fire based on IACO
    Liu, Zhaohui
    Zou, Ruihong
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [45] Safe Evacuation from Subway Station under Platform Train Fire
    Zeng, Sheng
    Zha, Xiaoxiong
    Chen, Yiyan
    Jiang, Ruijuan
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING III, PT 1, 2014, 638-640 : 2023 - +
  • [46] Ventilation mode analysis of exhaust smoke system for subway station fire
    Ouyang, Q
    Zhu, YX
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A and B, 2004, 4 : 1592 - 1596
  • [47] Smoke confinement utilizing the USME ventilation mode for subway station fire
    Luo, Na
    Li, Angui
    Gao, Ran
    Tian, Zhenguo
    Hu, Zhipei
    SAFETY SCIENCE, 2014, 70 : 202 - 210
  • [48] Cyclic loading behavior of a repaired subway station after fire exposure
    Zhao, Huiling
    Yu, Haitao
    Yuan, Yong
    Li, Pan
    Chen, Juntao
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 84 : 210 - 217
  • [49] Fuzzy synthesis assessment analysis of safety evacuation in subway station fire
    Xie Juan
    He Jiapeng
    Zhang Ye
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 338 - 341
  • [50] Influence of subway train fire locations on the characteristics of smoke movement in a curved tunnel
    Zhou, Dan
    Li, Jinzhu
    Hu, Tianen
    Chen, Tao
    PLOS ONE, 2023, 18 (01):