The Effect of Different Fire Source Locations on the Environment of a Subway Station

被引:5
|
作者
Lei, Wenjun [1 ,2 ]
Li, Angui [3 ]
Tai, Chuanmin [4 ]
机构
[1] Shandong Jianzhu Univ, Dept Bldg Environm & Energy ApplicationEngn, Jinan 250101, Shandong, Peoples R China
[2] Shandong Jianzhu Univ, State Minist Educ, Key Lab Renewable Energy Utilizat Technol Bldg, Jinan 250101, Shandong, Peoples R China
[3] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi, Peoples R China
[4] Shandong Jianzhu Univ, Architecture & Urban Planning Design Inst, Jinan 250101, Shandong, Peoples R China
关键词
Subway station; Fire source location; Temperature; Visibility; Carbon monoxide concentration; SMOKE; SIMULATION;
D O I
10.1016/j.proeng.2017.10.305
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effect of different fire source locations on the environment of a subway station was investigated in this paper. Visibility, temperature and carbon monoxide at the evacuation stairs in the subway station were computed by Fire Dynamics Simulator (FDS). Different fire source locations have different evacuation features. Fire source 2 and 3 have the most negative effect on evacuation. Therefore, relevant departments should take some measures to avoid fires breaking out in these places. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:3721 / 3726
页数:6
相关论文
共 50 条
  • [31] Analysis to Ventilation Effectiveness in Subway Fire Environment
    Wu, Wen-Zhong
    You, Shi-Jun
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 3206 - 3210
  • [32] Wave Motion of Smoke in Subway Fire Environment
    吴文忠
    由世俊
    Transactions of Tianjin University, 2009, 15 (03) : 206 - 209
  • [33] Wave motion of smoke in subway fire environment
    Wu W.
    You S.
    Transactions of Tianjin University, 2009, 15 (3) : 206 - 209
  • [34] CFD simulation on ventilation and evaluation of fire safety in subway station
    Wang, C
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 1392 - 1397
  • [35] Numerical Analysis of a Moderate Fire inside a Segment of a Subway Station
    Diaz, Rodrigo
    Wang, Hui
    Mang, Herbert
    Yuan, Yong
    Pichler, Bernhard
    APPLIED SCIENCES-BASEL, 2018, 8 (11):
  • [36] Simulation on Evacuation from the Subway Station under Fire Smoke
    Zhu Wei
    Zhou Xiao-feng
    Li Zhong-wei
    PROCEEDINGS OF ISCRAM ASIA 2012 CONFERENCE ON INFORMATION SYSTEMS FOR CRISIS RESPONSE AND MANAGEMENT, 2012, : 310 - 315
  • [37] Comparison of the smoke control strategy effects in a subway station fire
    Li Yanfeng
    Cai Na
    Li Junmei
    Chow, W. K.
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 865 - 868
  • [38] Life safety evacuation for cross interchange subway station fire
    Li Yanfeng
    Lin Xinxin
    Feng Xiao
    Wang Chao
    Li Junmei
    2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 : 741 - 747
  • [39] Prediction of the spread of smoke in a huge transit terminal subway station under six different fire scenarios
    Gao, Ran
    Li, Angui
    Hao, Xinpeng
    Lei, Wenjun
    Deng, Baoshun
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2012, 31 : 128 - 138
  • [40] Optimizing Fire Station Locations for the Istanbul Metropolitan Municipality
    Aktas, Emel
    Ozaydin, Ozay
    Bozkaya, Burcin
    Ulengin, Fusun
    Onsel, Sule
    INTERFACES, 2013, 43 (03) : 240 - 255