The Effect of Different Fire Source Locations on the Environment of a Subway Station

被引:5
|
作者
Lei, Wenjun [1 ,2 ]
Li, Angui [3 ]
Tai, Chuanmin [4 ]
机构
[1] Shandong Jianzhu Univ, Dept Bldg Environm & Energy ApplicationEngn, Jinan 250101, Shandong, Peoples R China
[2] Shandong Jianzhu Univ, State Minist Educ, Key Lab Renewable Energy Utilizat Technol Bldg, Jinan 250101, Shandong, Peoples R China
[3] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi, Peoples R China
[4] Shandong Jianzhu Univ, Architecture & Urban Planning Design Inst, Jinan 250101, Shandong, Peoples R China
关键词
Subway station; Fire source location; Temperature; Visibility; Carbon monoxide concentration; SMOKE; SIMULATION;
D O I
10.1016/j.proeng.2017.10.305
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effect of different fire source locations on the environment of a subway station was investigated in this paper. Visibility, temperature and carbon monoxide at the evacuation stairs in the subway station were computed by Fire Dynamics Simulator (FDS). Different fire source locations have different evacuation features. Fire source 2 and 3 have the most negative effect on evacuation. Therefore, relevant departments should take some measures to avoid fires breaking out in these places. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:3721 / 3726
页数:6
相关论文
共 50 条
  • [21] Study of Life Safety on the Fire Accidents in the Subway Station
    Xie, Hua
    Xu, Yanying
    Zhang, Xu
    Chen, Jian
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 1029 - 1032
  • [22] Comparative analysis of evacuation simulation for a subway station fire
    Liu, Q. Q.
    Han, X.
    Shang, K.
    Wu, G. H.
    ISISS '2007: PROCEEDINGS OF THE INNOVATION AND SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2008, : 1166 - 1174
  • [23] Study on evacuation in subway transfer station fire by STEPS
    Li Yanfeng
    Sun Xiaolong
    Feng Xiao
    Wang Chao
    Li Junmei
    2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 : 735 - 740
  • [24] Subway station group decision and evaluation of fire emergency
    Cao, Lijun
    Yu, Xiangmei
    Geng, Dongyang
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 1408 - 1411
  • [25] Subway Station Fire Prevention System Safety Analysis
    Wang Ruojun
    Jiang Bin
    Xu Yanying
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 1861 - 1864
  • [26] The Physiological Experimental Study on the Effect of Different Color of Safety Signs on a Virtual Subway Fire Escape-An Exploratory Case Study of Zijing Mountain Subway Station
    Chen, Na
    Zhao, Ming
    Gao, Kun
    Zhao, Jun
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (16) : 1 - 19
  • [27] Research on the Subway Station Environment Humanized Design
    Cao, Lei
    Zhao, Jing
    2017 INTERNATIONAL CONFERENCE ON FRONTIERS IN EDUCATIONAL TECHNOLOGIES AND MANAGEMENT SCIENCES (FETMS 2017), 2017, : 553 - 556
  • [28] Effect of platform screen doors on the indoor air environment of an underground subway station
    Han, Hwataik
    Lee, Jun-Yong
    Jang, Kyung-Jin
    INDOOR AND BUILT ENVIRONMENT, 2015, 24 (05) : 672 - 681
  • [29] Optimal fire station locations for historic wood building areas considering individual fire spread patterns and different fire risks
    Hou, Guanjie
    Li, Quanwang
    Song, Zhigang
    Zhang, Hao
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28 (28)
  • [30] Wave Motion of Smoke in Subway Fire Environment
    吴文忠
    由世俊
    Transactions of Tianjin University, 2009, (03) : 206 - 209