The Effect of Different Fire Source Locations on the Environment of a Subway Station

被引:5
|
作者
Lei, Wenjun [1 ,2 ]
Li, Angui [3 ]
Tai, Chuanmin [4 ]
机构
[1] Shandong Jianzhu Univ, Dept Bldg Environm & Energy ApplicationEngn, Jinan 250101, Shandong, Peoples R China
[2] Shandong Jianzhu Univ, State Minist Educ, Key Lab Renewable Energy Utilizat Technol Bldg, Jinan 250101, Shandong, Peoples R China
[3] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi, Peoples R China
[4] Shandong Jianzhu Univ, Architecture & Urban Planning Design Inst, Jinan 250101, Shandong, Peoples R China
关键词
Subway station; Fire source location; Temperature; Visibility; Carbon monoxide concentration; SMOKE; SIMULATION;
D O I
10.1016/j.proeng.2017.10.305
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effect of different fire source locations on the environment of a subway station was investigated in this paper. Visibility, temperature and carbon monoxide at the evacuation stairs in the subway station were computed by Fire Dynamics Simulator (FDS). Different fire source locations have different evacuation features. Fire source 2 and 3 have the most negative effect on evacuation. Therefore, relevant departments should take some measures to avoid fires breaking out in these places. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:3721 / 3726
页数:6
相关论文
共 50 条
  • [1] Fire smoke control in different structures of subway station
    Zhu, De-Zhi
    Jiang, Jun-Cheng
    Jiefangjun Ligong Daxue Xuebao/Journal of PLA University of Science and Technology (Natural Science Edition), 2008, 9 (06): : 681 - 686
  • [2] The effect of PSD on life safety in subway station fire
    Roh, Jae Seong
    Ryou, Hong Sun
    Yoon, Sung Wook
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2010, 24 (04) : 937 - 942
  • [3] The effect of PSD on life safety in subway station fire
    Jae Seong Roh
    Hong Sun Ryou
    Sung Wook Yoon
    Journal of Mechanical Science and Technology, 2010, 24 : 937 - 942
  • [4] Personnel evacuation research of subway transfer station based on fire environment
    Li, Yanfeng
    Wang, Hongyi
    Wang, Chao
    Huang, Youbo
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 431 - 437
  • [5] The Effect of Heat Release Rate on the Environment of a Subway Station
    Lei, Wenjun
    Li, Angui
    Tai, Chuanmin
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3717 - 3720
  • [6] Numerical study on the ceiling gas temperature in a subway train with different fire locations
    Cong, Wei
    Shi, Long
    Shi, Zhicheng
    Peng, Min
    Yang, Hui
    Cheng, Xudong
    BUILDING SIMULATION, 2022, 15 (04) : 549 - 560
  • [7] Numerical study on the ceiling gas temperature in a subway train with different fire locations
    Wei Cong
    Long Shi
    Zhicheng Shi
    Min Peng
    Hui Yang
    Xudong Cheng
    Building Simulation, 2022, 15 : 549 - 560
  • [8] NUMERICAL FIRE SIMULATION IN SUBWAY STATION TUNNEL BY USING DIFFERENT COMBUSTION MODELS
    Karaaslan, Salih
    Dinler, Nureddin
    Yucel, Nuri
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2011, 26 (03): : 533 - 547
  • [9] CFD Analysis on Fire Feature of Subway Station with Different Location of Ticket Machine
    Han, Xin
    Li, Chongyu
    Cong, Beihua
    ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 1207 - +
  • [10] Smoke diffusion and control at different platform floor structure of subway station in fire
    Zhou, Ru
    He, Jiapeng
    Jiang, Juncheng
    Tang, Xiaoliang
    Zhongguo Tiedao Kexue/China Railway Science, 2008, 29 (06): : 126 - 131