Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial

被引:173
作者
MacDonald, SJ
McCalden, RW
Chess, DG
Bourne, RB
Rorabeck, CH
Cleland, A
Leung, F
机构
[1] London Hlth Sci Ctr, London, ON N6A 5A5, Canada
[2] Univ Western Ontario, Div Orthopaed Surg, London, ON, Canada
[3] St Josephs Hlth Care Ctr, Div Orthopaed Surg, London, ON, Canada
[4] London Hlth Sci Ctr, Dept Lab Med, London, ON, Canada
关键词
D O I
10.1097/01.blo.0000043066.62337.9d
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective, randomized, blinded clinical trial was done to evaluate polyethylene versus metal bearing surfaces in total hip replacement. Forty-one patients were randomized to receive either a metal (23 patients) or a polyethylene (18 patients) insert. The femoral and acetabular components were identical with the acetabular insert the only variable. Patients were assessed preoperatively and postoperatively using radiographs, multiple outcome measures (Western Ontario MacMaster University Score, Harris hip score, Short Form-12), erythrocyte metal ion analysis (cobalt, chromium, titanium), and urine metal ion analysis (cobalt, chromium, titanium). Patients were followed up for a minimum of 2 years (mean 3.2 years; range, 2.2-3.9 years). There were no differences in radiographic outcomes or outcome measurement tools between patients. Patients receiving a metal-onmetal articulation had significantly elevated erythrocyte and urine metal ions compared with patients receiving a polyethylene insert. Patients who had metal-on-metal inserts had on average a 7.9-fold increase in erythrocyte cobalt, a 2.3-fold increase in erythrocyte chromium, a 1.7-fold increase in erythrocyte titanium, a 35.1-fold increase in urine cobalt, a 17.4-fold increase in urine chromium, and a 2.6-fold increase in urine titanium at 2 years followup. Patients receiving a polyethylene insert had no change in erythrocyte titanium, urine cobalt, or urine chromium and a 1.5-fold increase in erythrocyte cobalt, a 2.2-fold increase in erythrocyte chromium, and a 4.2-fold increase in urine titanium. Forty-one percent of patients receiving metal-on-metal articulations had increasing metal ion levels at the latest followup.
引用
收藏
页码:282 / 296
页数:15
相关论文
共 41 条
[1]  
*AN SOC TEST MAT, 2001, ANN BOOK ASTM STAND
[2]  
Barrack RL, 1997, CLIN ORTHOP RELAT R, P211
[3]   CHROMIUM CONCENTRATIONS IN SERUM, BLOOD CLOT AND URINE FROM PATIENTS FOLLOWING TOTAL HIP-ARTHROPLASTY [J].
BARTOLOZZI, A ;
BLACK, J .
BIOMATERIALS, 1985, 6 (01) :2-8
[4]  
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[5]   A PRELIMINARY EVALUATION OF THE DIMENSIONALITY AND CLINICAL IMPORTANCE OF PAIN AND DISABILITY IN OSTEOARTHRITIS OF THE HIP AND KNEE [J].
BELLAMY, N ;
BUCHANAN, WW .
CLINICAL RHEUMATOLOGY, 1986, 5 (02) :231-241
[6]   CATASTROPHIC FAILURE OF THE POLYETHYLENE LINER OF UNCEMENTED ACETABULAR COMPONENTS [J].
BERRY, DJ ;
BARNES, CL ;
SCOTT, RD ;
CABANELA, ME ;
POSS, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04) :575-578
[7]   SERUM CONCENTRATIONS OF CHROMIUM, COBALT AND NICKEL AFTER TOTAL HIP-REPLACEMENT - A 6 MONTH STUDY [J].
BLACK, J ;
MAITIN, EC ;
GELMAN, H ;
MORRIS, DM .
BIOMATERIALS, 1983, 4 (03) :160-164
[8]  
Bono J V, 1994, J Arthroplasty, V9, P119, DOI 10.1016/0883-5403(94)90059-0
[9]  
BRIEN WW, 1992, CLIN ORTHOP RELAT R, P66
[10]   Elevated serum cobalt with metal-on-metal articulating surfaces [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
GottsaunerWolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :316-321