Accuracy of reconstructed images from cone-beam computed tomography scans

被引:3
|
作者
Lamichane, Manish
Anderson, Nina Kay [2 ]
Rigali, Paul H. [1 ]
Seldin, Edward B. [3 ,4 ]
Will, Leslie A. [1 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Orthodont, Boston, MA 02111 USA
[2] Harvard Univ, Sch Dent Med, Dept Dev Biol, Boston, MA 02115 USA
[3] Harvard Univ, Sch Dent Med, Dept Oral & Maxillofacial Surg, Boston, MA 02115 USA
[4] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
LANDMARK IDENTIFICATION; CT; NEWTOM; CEPHALOMETRY; DOSIMETRY; DEVICES; FILM;
D O I
10.1016/j.ajodo.2009.01.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to determine whether 2-dimensional (2D) images produced from cone-beam computed tomography (CBCT) images taken with an iCAT scanner (Imaging Sciences International, Hatfield, Pa) can substitute for traditional cephalograms. Methods: Lateral and frontal cephalograms were taken of a radiographic phantom with known dimensions. Landmarks on the 2D images were traced and measured manually by 2 examiners and then digitally in Dolphin 10 (Dolphin Imaging Sciences, Chats-worth, Calif) by the same examiners. A CBCT scan was taken of the phantom, and orthogonal and perspective projections were created from the scans. Frontal and lateral cephalograms were created by using the 3-dimensional function in Dolphin 10, digitized into Dolphin, and traced by the same 2 examiners. Linear measurements were compared to assess the accuracy of the generated images from the CBCT scans. Results: Measurements on the orthogonal projections were not significantly different from the actual dimensions of the phantom, and measurements on the perspective projections were highly correlated with those taken on standard 2D films. Conclusions: By constructing a perspective lateral cephalogram from a CBCT scan, one can replicate the inherent magnification of a conventional 2D lateral cephalogram with high accuracy. (Am J Orthod Dentofacial Orthop 2009;136:156.e1-156.e6)
引用
收藏
页码:156.e1 / 156.e6
页数:8
相关论文
共 50 条
  • [21] Accuracy of cone-beam computed tomography for syndesmosis injury diagnosis compared to conventional computed tomography
    Hamard, Marion
    Neroladaki, Angeliki
    Bagetakos, Ilias
    Dubois-Ferriere, Victor
    Montet, Xavier
    Boudabbous, Sana
    FOOT AND ANKLE SURGERY, 2020, 26 (04) : 265 - 272
  • [22] Prevalence and Characteristics of Root Resorption Identified in Cone-Beam Computed Tomography Scans
    Dao, Vi
    Mallya, Sanjay M.
    Markovic, Daniela
    Tetradis, Sotirios
    Chugal, Nadia
    JOURNAL OF ENDODONTICS, 2023, 49 (02) : 144 - 154
  • [23] Incidental Findings in Small Field of View Cone-beam Computed Tomography Scans
    Oser, David G.
    Henson, Brett R.
    Shiang, Elaine Y.
    Finkelman, Matthew D.
    Amato, Robert B.
    JOURNAL OF ENDODONTICS, 2017, 43 (06) : 901 - 904
  • [24] Comparison of Cephalometric Radiographs Obtained From Cone-Beam Computed Tomography Scans and Conventional Radiographs
    van Vlijmen, Olivier J. C.
    Berge, Stefaan J.
    Swennen, Gwen R. J.
    Bronkhorst, Ewald M.
    Katsaros, Christos
    Kuijpers-Jagtman, Anne M.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (01) : 92 - 97
  • [25] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [26] An In Vitro Comparison of the Accuracy of Measurements Obtained from High- and Low-resolution Cone-beam Computed Tomography Scans
    Hashem, Danya
    Brown, Jackie E.
    Patel, Shanon
    Mannocci, Francesco
    Donaldson, Ana Nora
    Watson, Timothy F.
    Banerjee, Avijit
    JOURNAL OF ENDODONTICS, 2013, 39 (03) : 394 - 397
  • [27] Accuracy of cone-beam computed tomography in imaging the components of the periodontal phenotype
    Schulze, Ralf
    Couso-Queiruga, Emilio
    Katsaros, Christos
    PERIODONTOLOGY 2000, 2024,
  • [28] Zygomaticofacial foramen location accuracy and reliability in cone-beam computed tomography
    del Neri, Nathalia Bigelli
    Araujo-Pires, Ana Claudia
    Andreo, Jesus Carlos
    Fisher Rubira-Bullen, Izabel Regina
    Ferreira Junior, Osny
    ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (02) : 157 - 160
  • [29] Accuracy assessment of the axial images obtained from cone beam computed tomography
    Panzarella, F. K.
    Junqueira, J. L. C.
    Oliveira, L. B.
    de Araujo, N. S.
    Costa, C.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (06) : 369 - 378
  • [30] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    DENTISTRY JOURNAL, 2019, 7 (03)