Complications of Volar Plate Fixation for Managing Distal Radius Fractures

被引:124
作者
Berglund, Lisa M. [1 ]
Messer, Terry M. [2 ]
机构
[1] Univ N Carolina, Dept Orthopaed, Chapel Hill, NC 27514 USA
[2] Univ N Carolina, Sch Med, Raleigh Hand Ctr, Dept Orthopaed, Raleigh, NC USA
关键词
PRONATOR QUADRATUS COMPARTMENT; POLLICIS LONGUS RUPTURE; REGIONAL PAIN SYNDROME; LOCKING-PLATE; INTERNAL-FIXATION; WRIST FRACTURES; OPEN REDUCTION; VITAMIN-C; TENDON; SYSTEM;
D O I
10.5435/00124635-200906000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Volar locking plate fixation via open reduction and internal fixation is an increasingly accepted method for managing displaced distal radius fractures. Volar plating offers biomechanically stable fixation, allows early rehabilitation, and enables fixation of comminuted or osteopenic bone. The literature reporting complications of volar plate fixation is limited primarily to case reports and small case series. The surgeon must be mindful of potential soft-tissue, neurovascular, and osseous complications, such as extensor tendon and flexor tendon injury, flexor pollicis rupture, carpal tunnel syndrome, complex regional pain syndrome, and loss of reduction, as well as hardware failure. Increased awareness of potential complications may lead to more prompt recognition and treatment when they do arise.
引用
收藏
页码:369 / 377
页数:9
相关论文
共 59 条
[1]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[2]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]   FLEXOR POLLICIS LONGUS RUPTURE AFTER FRACTURE OF THE DISTAL RADIUS [J].
ASHALL, G .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1991, 22 (02) :153-155
[4]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[5]   Two potential causes of EPL rupture after distal radius volar plate fixation [J].
Benson, Eric C. ;
DeCarvalho, Alex ;
Mikola, Elizabeth A. ;
Veitch, John M. ;
Moneim, Moheb S. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) :218-222
[6]   The outcome of intra-articular distal radius fractures treated with fragment-specific fixation [J].
Benson, Leon S. ;
Minihane, Keith P. ;
Stern, Laura D. ;
Eller, Erik ;
Seshadri, Roopa .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (08) :1333-1339
[7]   Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures [J].
Bhattacharyya, Timothy ;
Wadgaonkar, Ajay D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (02) :401-403
[8]   Peripheral nerve compression neuropathy after fractures of the distal radius [J].
Bienek, T. ;
Kusz, D. ;
Cielinski, L. .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2006, 31B (03) :256-260
[9]   Precontoured fixed-angle volar distal radius plates: A comparison of anatomic fit [J].
Buzzell, Jonathan E. ;
Weikert, Douglas R. ;
Watson, Jeffry T. ;
Lee, Donald H. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (07) :1144-1152
[10]  
Cazeneuve J F, 2002, Acta Orthop Belg, V68, P481