Short-, mid-, and long-term reproducibility of the atrial signal-averaged electrocardiogram in healthy subjects: Comparison with the conventional ventricular signal-averaged electrocardiogram

被引:12
作者
Savelieva, I [1 ]
Aytemir, K [1 ]
Hnatkova, K [1 ]
Camm, AJ [1 ]
Malik, M [1 ]
机构
[1] St George Hosp, Sch Med, Dept Cardiol Sci, London SW17 0RE, England
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2000年 / 23卷 / 01期
关键词
signal-averaged electrocardiography; filtered P wave; automatic measurement;
D O I
10.1111/j.1540-8159.2000.tb00657.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although atrial signal-averaged electrocardiogram (SAECG) has been proposed for noninvasive identification of patients with atrial tachyarrhythmias, the substantial variability of the measurement limits the clinical value. The aim of the study was to assess the short- to long-term reproducibility of atrial SAECG and to compare it to that of the conventional ventricular SAECG in 51 healthy volunteers (30 men; age 32 +/- 8 years). In each subject, SAECG recordings were obtained using MAC-VU electrocardiograph and HiRES and PHiRES software (Marquette Medical Systems) and repeated after 5 minutes, 1 day, 1 week, and 1 month. Automatically detected onset and offset of the filtered QRS complex and P wave were subsequently corrected by two independent observers, and the averaged values were used for the analysis. Conventional ventricular SAECG parameters: filtered QRS duration (QRS(tot)), low amplitude signal duration, and root mean square voltage (RMS) of the terminal 40 ms of QRS; and 5 atrial parameters: filtered P wave duration (P-tot), RMS of the terminal 40, 30, 20 ms, and of the entire P wave were obtained. Relative errors of different pairs of measures were used to assess the intrasubject reproducibility. QRS(tot) and P-tot were the most reproducible parameters. The relative errors after 5 minutes, 1 day, 1 week, and 1 month were 0.8% to 2.4% for QRS(tot), and 1.3% to 4.2% for P-tot. For RMS voltages, the relative errors exceeded 15% in short-term and 20% in long-term recordings. Although P-tot as statistically less reproducible than QRS(tot), the reproducibility of the former was good and comparable to that of the QRS(tot). The reproducibility of the voltage parameters was significantly poorer than that of the duration parameters. The study showed a satisfactory short- and long-term reproducibility of P-tot in the atrial SAECG in healthy subjects. However, low reproducibility of the Voltage parameters should be considered in clinical applications.
引用
收藏
页码:122 / 127
页数:6
相关论文
共 16 条
[1]  
[Anonymous], MED ELECTRONICS
[2]   EFFECTS OF AUTONOMIC STIMULATION AND BLOCKADE ON SIGNAL-AVERAGED P-WAVE DURATION [J].
CHEEMA, AN ;
AHMED, MW ;
KADISH, AH ;
GOLDBERGER, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (02) :497-502
[3]   Within- and between-patient variation of the signal-averaged P wave in coronary artery disease [J].
Christiansen, EH ;
Frost, L ;
Pilegaard, H ;
ToftegaardNielsen, T ;
Pedersen, AK .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (01) :72-81
[4]  
Dhala A, 1997, J ELECTROCARDIOL, V30, P34
[5]   Evaluation of P wave signal-averaged electrocardiographic filtering and analysis methods [J].
Ehlert, FA ;
Korenstein, D ;
Steinberg, JS .
AMERICAN HEART JOURNAL, 1997, 134 (06) :985-993
[6]   Immediate and short-term reproducibility of the P wave signal-averaged electrocardiogram [J].
Ehlert, FA ;
Zaman, N ;
Steinberg, JS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (06) :1636-1645
[7]   REPRODUCIBILITY OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM [J].
ENGEL, TR ;
PIERCE, DL ;
PATIL, KD .
AMERICAN HEART JOURNAL, 1991, 122 (06) :1652-1660
[8]   DETECTION OF PATIENTS AT RISK FOR PAROXYSMAL ATRIAL-FIBRILLATION DURING SINUS RHYTHM BY P-WAVE TRIGGERED SIGNAL-AVERAGED ELECTROCARDIOGRAM [J].
FUKUNAMI, M ;
YAMADA, T ;
OHMORI, M ;
KUMAGAI, K ;
UMEMOTO, K ;
SAKAI, A ;
KONDOH, N ;
MINAMINO, T ;
HOKI, N .
CIRCULATION, 1991, 83 (01) :162-169
[9]   CORRELATION OF SIGNAL-AVERAGED P-WAVE WITH ELECTROPHYSIOLOGICAL TESTING FOR ATRIAL VULNERABILITY IN STROKES OF UNEXPLAINED ETIOLOGY [J].
GENCEL, L ;
POQUET, F ;
GOSSE, P ;
HAISSAGUERRE, M ;
MARCUS, FI ;
CLEMENTY, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :2118-2124
[10]   THE SIGNAL-AVERAGED P-WAVE DURATION - A RAPID AND NONINVASIVE MARKER OF RISK OF ATRIAL-FIBRILLATION [J].
GUIDERA, SA ;
STEINBERG, JS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) :1645-1651