IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING

被引:22
作者
Carrasco, Thaise Graciele [1 ]
Carrasco-Guerisoli, Laise Daniela [1 ]
Froner, Izabel Cristina [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Restorat Dent, Ribeirao Preto, SP, Brazil
关键词
Tooth bleaching; Dental pulp cavity;
D O I
10.1590/S1678-77572008000500010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38 +/- 0.66 degrees C). The LED unit produced the lowest temperature increase (0.29 +/- 0.13 degrees C); but there was no significant difference between LED unit and LED-laser system (0.35 +/- 0.15 degrees C) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41 +/- 0.64 degrees C), and LED-laser system the lowest (0.33 +/- 0.12 degrees C); however, there was no difference between LED-laser system and LED unit (0.44 +/- 0.11 degrees C). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.
引用
收藏
页码:355 / 359
页数:5
相关论文
共 23 条
  • [1] Temperature rise during experimental light-activated bleaching
    Klaric, Eva
    Rakic, Mario
    Sever, Ivan
    Tarle, Zrinka
    LASERS IN MEDICAL SCIENCE, 2015, 30 (02) : 567 - 576
  • [2] Temperature rise during experimental light-activated bleaching
    Eva Klaric
    Mario Rakic
    Ivan Sever
    Zrinka Tarle
    Lasers in Medical Science, 2015, 30 : 567 - 576
  • [3] The effect of laser-activated bleaching with 445 nm and 970 nm diode lasers on pulp chamber temperature rise: an in vitro study
    Saberi, Sogol
    Shahabi, Sima
    Tohidkhah, Saba
    Jafarnia, Shiva
    Pedram, Parham
    LASER PHYSICS, 2021, 31 (05)
  • [4] In vitro evaluation of halogen light-activated vs chemically activated in-office bleaching systems
    Liang, Shanshan
    Sa, Yue
    Jiang, Tao
    Ma, Xiao
    Xing, Wenzhong
    Wang, Zhejun
    Wang, Yining
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) : 1149 - 1155
  • [5] In vitro evaluation of visible light-activated titanium dioxide photocatalysis for in-office dental bleaching
    Cuppini, Marla
    Branco Leitune, Vicente Castelo
    de Souza, Marcela
    Alves, Annelise Kopp
    Werner Samuel, Susana Maria
    Collares, Fabricio Mezzomo
    DENTAL MATERIALS JOURNAL, 2019, 38 (01) : 68 - 74
  • [6] Temperature changes in the pulp chamber and bleaching gel during tooth bleaching assisted by diode laser (445 nm) using different power settings
    Papadopoulou, Aggeliki
    Dionysopoulos, Dimitrios
    Strakas, Dimitrios
    Kouros, Pantelis
    Kolokitha, Olga-Elpis
    Tolidis, Kosmas
    LASERS IN MEDICAL SCIENCE, 2023, 38 (01)
  • [7] Temperature changes in the pulp chamber and bleaching gel during tooth bleaching assisted by diode laser (445 nm) using different power settings
    Aggeliki Papadopoulou
    Dimitrios Dionysopoulos
    Dimitrios Strakas
    Pantelis Kouros
    Olga-Elpis Kolokitha
    Kosmas Tolidis
    Lasers in Medical Science, 38
  • [8] In-office dental bleaching with violet light emitting diode: bleaching efficacy and pulpal temperature rise
    de Almeida Guanaes, Brunna Katyuscia
    Duarte, Talyta Neves
    Correr, Gisele Maria
    Kaizer, Marina da Rosa
    Gonzaga, Carla Castiglia
    RESTORATIVE DENTISTRY AND ENDODONTICS, 2022, 47 (01)
  • [9] In vitro evaluation of the effect of different bleaching varnishes: Hydrogen peroxide penetration into the pulp chamber and color change
    Carneiro, Taynara S.
    Favoreto, Michael W.
    Mena-Serrano, Alexandra
    Wendlinger, Michel
    Forville, Heloisa
    Reis, Alessandra
    Ceballos, Laura
    Loguercio, Alessandro D.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (02) : 402 - 409
  • [10] In vivo temperature rise in anesthetized human pulp during exposure to a polywave LED light curing unit
    Runnacles, Patricio
    Galvao Arrais, Cesar Augusto
    Pochapski, Marcia Thais
    dos Santos, Fabio Andre
    Coelho, Ulisses
    Gomes, Joao Carlos
    De Goes, Mario Fernando
    Mongruel Gomes, Osnara Maria
    Rueggeberg, Frederick Allen
    DENTAL MATERIALS, 2015, 31 (05) : 505 - 513