On-Line and Real-Time Analysis of Moisture Content in Activated Carbon Powder by X-Ray Scattering Technique

被引:2
作者
Choi, Yong Suk [1 ]
Hwang, Jaesik [2 ]
Kim, Jong-Yun [1 ]
机构
[1] Korea Atom Energy Res Inst, Nucl Chem Res Div, Taejon 305353, South Korea
[2] Korea Inst Ind Technol, Cheonan Si 331822, Chungcheongnam, South Korea
基金
新加坡国家研究基金会;
关键词
Real-time; On-line; X-Ray; Moisture; Activated carbon; ANALYTICAL-CHEMISTRY; WATER;
D O I
10.14233/ajchem.2014.17715
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
On-line and real-time analyses of moisture in activated carbon powders were performed using a pilot-scale X-ray monitoring system. The system was composed of an X-ray tube generator as an X-ray source, a cadmium telluride (CdTe) X-ray detector and a circular rotating disk to simulate real processes. Total X-ray scattering intensities from the powder samples moving at a speed of 4 m/min were measured with a very short counting time of 0.1 s. The wet powder samples with various moisture contents were successfully monitored in real-time using our in-house built X-ray scattering measurement system.
引用
收藏
页码:4067 / 4069
页数:3
相关论文
共 49 条
  • [1] Real-time x-ray imaging with flat panels
    Gilblom, D
    Colbeth, R
    Batts, M
    Meyer, B
    PROCESS CONTROL AND SENSORS FOR MANUFACTURING, 1998, 3399 : 213 - 223
  • [2] Characterization of activated carbon fibers by small angle x-ray scattering
    Cazorla-Amoros, D
    de Lecea, CSM
    Alcaniz-Monge, J
    Gardner, M
    North, A
    Dore, J
    CARBON, 1998, 36 (03) : 309 - 312
  • [3] Analysis of activated carbon from city solid waste by small angle x-ray scattering
    Rong, LX
    Xie, LP
    Dong, BZ
    Lin, WG
    Wang, J
    ACTA PHYSICA SINICA, 2003, 52 (03) : 630 - 634
  • [4] Flat X-ray image intensifier system for real-time fluoroscopy
    Onihashi, H
    Aida, H
    Nou, K
    Noji, T
    Murakoshi, Y
    Saito, K
    Koma, J
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 145 - 150
  • [5] Real-time radio-transparent dosimeter for X-ray imaging system
    Staub, D
    Cailleret, J
    Guyonnet, JL
    Le, TD
    Wurtz, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2) : 303 - 307
  • [6] In-situ real-time x-ray quality assessment of BGA and uBGA connections during soldering
    Scholz, O
    Eisenbarth, M
    Hanke, R
    Bigl, T
    Schmitt, P
    TESTING, RELIABILITY, AND APPLICATION OF MICRO- AND NANO-MATERIAL SYSTEMS, 2003, 5045 : 147 - 156
  • [7] Real-time pose estimation of devices from x-ray images: Application to x-ray/echo registration for cardiac interventions
    Hatt, Charles R.
    Speidel, Michael A.
    Raval, Amish N.
    MEDICAL IMAGE ANALYSIS, 2016, 34 : 101 - 108
  • [8] A New Imaging Method for Real-time 3D X-ray Reconstruction
    Tahtali, Murat
    Saha, Sajib K.
    Lambert, Andrew J.
    Pickering, Mark R.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [9] Real-time contrast medium detection in x-ray images by mathematical morphology operators
    Ly, Dieu Sang
    Beucher, Serge
    Bilodeau, Michel
    JOURNAL OF ELECTRONIC IMAGING, 2015, 24 (06)
  • [10] Real-time X-ray Imaging of Lung Fluid Volumes in Neonatal Mouse Lung
    Van Avermaete, Ashley E.
    Trac, Phi T.
    Gauthier, Theresa W.
    Helms, My N.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (113):