A passive decay heat removal strategy of the integrated passive safety system (IPSS) for SBO combined with LOCA

被引:5
作者
Kim, Sang Ho [1 ]
Chang, Soon Heung [2 ]
Choi, Yu Jung [3 ]
Jeong, Yong Hoon [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Daejeon 34141, South Korea
[2] Handong Global Univ, Pohang Gyeongbuk 37554, South Korea
[3] Korea Hydro & Nucl Power Co, Cent Res Inst, Daejeon 34101, South Korea
基金
新加坡国家研究基金会;
关键词
AUXILIARY FEEDWATER SYSTEM; DESIGN; BREAK; CODE;
D O I
10.1016/j.nucengdes.2015.09.033
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An integrated passive safety system (IPSS), to be achieved by the use of a large water tank placed at high elevation outside the containment, was proposed to achieve various passive functions. These include decay heat removal, safety injection, containment cooling, in-vessel retention through external reactor vessel cooling, and containment filtered venting. The purpose of the passive decay heat removal (PDHR) strategy using the IPSS is to cope with SBO and SBO-combined accidents under the assumption that existing engineered safety features have failed. In this paper, a PDHR strategy was developed based on the design and accident management strategy of Korean representative PWR, the OPR1000. The functions of a steam generator gravity injection and a passive safety injection system in the IPSS with safety depressurization systems were included in the PDHR strategy. Because the inadvertent opening of pressurizer valves and seal water leakage from RCPs could cause a loss of coolant in an SBO, LOCAs during a SBO were simulated to verify the performance of the strategy. The failure of active safety injection in LOCAs could also be covered by this strategy. Although LOCAs have generally been categorized according to their equivalent break diameters, the RCS pressure is used to classify the LOCAs during SBOs. The criteria values for categorization were determined from the proposed systems, which could maintain a reactor in a safe state by removing the decay heat for the SBO coping time of 8 h. The accidents were simulated by MARS code considering several specific processes characterized from LOCA and SBO. For a high-pressure LOCA, water in an IPST could be injected into a steam generator using gravity after depressurization of the secondary circuit caused by opening atmospheric dump valves. For a low-pressure LOCA, the pressure in the RCS naturally decreased due to coolant loss. Additional depressurization was needed during LOCAs for which RCS criteria pressures at the time of estimation were in the range between high-pressure LOCA and low-pressure LOCA. This is referred to as medium-pressure LOCA, according to the range of the RCS pressure. The procedures of the PDHR strategy can be implemented after failure of the steps in emergency operating procedures, before entering the condition for the severe accident management. Even when external conditions make a given site extremely inaccessible, the PDFIR strategy can allow for cooling the core in an EDMG by installing an IPSS beside each nuclear power plant. The proposed PDHR strategy can be applied in both current and future nuclear power plants by considering modifications for enhancing their safety. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:346 / 359
页数:14
相关论文
共 50 条
  • [31] Heat transfer evaluation of natural convection outside the condenser in Passive Residual Heat Removal System of Molten Salt Reactor
    Ding Tao
    Yang Guang-liang
    Fan Guang-ming
    Tian Chun-Ping
    Meng Zhao-Ming
    Chen Kal-lun
    Yan Chang-Qi
    Chen Hong-li
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [32] Experimental study on the influence of inclination on operating characteristics of secondary side passive residual heat removal system
    Sun, Ao
    Cheng, Jie
    Yan, Changqi
    Zhu, Dongbao
    Tian, Chunping
    Li, Pengzheng
    ANNALS OF NUCLEAR ENERGY, 2023, 191
  • [33] Numerical investigations on the performance of passive heat removal system of small modular reactor under accidental conditions
    Adinarayana, K. N. V.
    Rao, P. Mangarjuna
    Ali, Seik Mansoor
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 162
  • [34] 3D CFD simulation of passive decay heat removal system under boiling conditions: Role of bubble sliding motion on inclined heated tubes
    Minocha, Nitin
    Joshi, Jyeshtharaj Bhalchandra
    Nayak, Arun Kumar
    Vijayan, Pallipattu Krishnan
    CHEMICAL ENGINEERING SCIENCE, 2016, 145 : 245 - 265
  • [35] Heat pipe type double-containment vessel as passive safety system for small modular reactors
    Jung, Ju Hun
    Kim, Ji Yong
    Lee, Dong Hun
    Bang, In Cheol
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (03)
  • [36] Experimental study on the heat transfer characteristics of fluoride salt in the new conceptual passive heat removal system of molten salt reactor
    Liu, Minghao
    Zhang, Dalin
    Wang, Chenglong
    Qiu, Suizheng
    Su, G. H.
    Tian, Wenxi
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (04) : 1635 - 1648
  • [37] Experimental study on transient performance of heat pipe-cooled passive residual heat removal system of a molten salt reactor
    Wang, Chenglong
    Liu, Minghao
    Zhang, Dalin
    Qiu, Suizheng
    Su, G. H.
    Tian, Wenxi
    PROGRESS IN NUCLEAR ENERGY, 2020, 118
  • [38] Analysis of start-up and long-term operation characteristics of passive residual heat removal system
    Lyu, Xing
    Peng, Minjun
    Xia, Genglei
    ANNALS OF NUCLEAR ENERGY, 2019, 130 : 69 - 81
  • [39] Development of the analysis tool for the water cooling type passive residual heat removal system of Chinese pressurized reactor
    Huang, Tao
    Zhang, Y. P.
    Gong, Houjun
    Tian, W. X.
    Su, G. H.
    Qiu, S. Z.
    PROGRESS IN NUCLEAR ENERGY, 2016, 90 : 164 - 174
  • [40] Experimental investigation on natural circulation characteristics of emergency passive residual heat removal system in HPR1000
    Sun, D. C.
    Xi, Z.
    Li, Y.
    Zan, Y. F.
    Xiong, W. Y.
    Li, P. Z.
    Zhuo, W. B.
    PROGRESS IN NUCLEAR ENERGY, 2018, 103 : 1 - 7