A passive decay heat removal strategy of the integrated passive safety system (IPSS) for SBO combined with LOCA

被引:5
|
作者
Kim, Sang Ho [1 ]
Chang, Soon Heung [2 ]
Choi, Yu Jung [3 ]
Jeong, Yong Hoon [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Daejeon 34141, South Korea
[2] Handong Global Univ, Pohang Gyeongbuk 37554, South Korea
[3] Korea Hydro & Nucl Power Co, Cent Res Inst, Daejeon 34101, South Korea
基金
新加坡国家研究基金会;
关键词
AUXILIARY FEEDWATER SYSTEM; DESIGN; BREAK; CODE;
D O I
10.1016/j.nucengdes.2015.09.033
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An integrated passive safety system (IPSS), to be achieved by the use of a large water tank placed at high elevation outside the containment, was proposed to achieve various passive functions. These include decay heat removal, safety injection, containment cooling, in-vessel retention through external reactor vessel cooling, and containment filtered venting. The purpose of the passive decay heat removal (PDHR) strategy using the IPSS is to cope with SBO and SBO-combined accidents under the assumption that existing engineered safety features have failed. In this paper, a PDHR strategy was developed based on the design and accident management strategy of Korean representative PWR, the OPR1000. The functions of a steam generator gravity injection and a passive safety injection system in the IPSS with safety depressurization systems were included in the PDHR strategy. Because the inadvertent opening of pressurizer valves and seal water leakage from RCPs could cause a loss of coolant in an SBO, LOCAs during a SBO were simulated to verify the performance of the strategy. The failure of active safety injection in LOCAs could also be covered by this strategy. Although LOCAs have generally been categorized according to their equivalent break diameters, the RCS pressure is used to classify the LOCAs during SBOs. The criteria values for categorization were determined from the proposed systems, which could maintain a reactor in a safe state by removing the decay heat for the SBO coping time of 8 h. The accidents were simulated by MARS code considering several specific processes characterized from LOCA and SBO. For a high-pressure LOCA, water in an IPST could be injected into a steam generator using gravity after depressurization of the secondary circuit caused by opening atmospheric dump valves. For a low-pressure LOCA, the pressure in the RCS naturally decreased due to coolant loss. Additional depressurization was needed during LOCAs for which RCS criteria pressures at the time of estimation were in the range between high-pressure LOCA and low-pressure LOCA. This is referred to as medium-pressure LOCA, according to the range of the RCS pressure. The procedures of the PDHR strategy can be implemented after failure of the steps in emergency operating procedures, before entering the condition for the severe accident management. Even when external conditions make a given site extremely inaccessible, the PDFIR strategy can allow for cooling the core in an EDMG by installing an IPSS beside each nuclear power plant. The proposed PDHR strategy can be applied in both current and future nuclear power plants by considering modifications for enhancing their safety. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:346 / 359
页数:14
相关论文
共 50 条
  • [1] Design of integrated passive safety system (IPSS) for ultimate passive safety of nuclear power plants
    Chang, Soon Heung
    Kim, Sang Ho
    Choi, Jae Young
    NUCLEAR ENGINEERING AND DESIGN, 2013, 260 : 104 - 120
  • [2] A passive decay heat removal system for LWRs based on air cooling
    Mochizuki, Hiroyasu
    Yano, Takahiro
    NUCLEAR ENGINEERING AND DESIGN, 2015, 286 : 139 - 149
  • [3] Experimental investigation on the heat removal capacity of secondary side passive residual heat removal system for an integrated reactor
    Li, Junlong
    Qi, Zhanfei
    Cao, Kemei
    Liu, Maolong
    Yang, Zijiang
    Xiao, Yao
    Xiong, Zhenqin
    Gu, Hanyang
    APPLIED THERMAL ENGINEERING, 2022, 204
  • [4] LOCA analysis of SCWR-M with passive safety system
    Liu, X. J.
    Fu, S. W.
    Xu, Z. H.
    Yang, Y. H.
    Cheng, X.
    NUCLEAR ENGINEERING AND DESIGN, 2013, 259 : 187 - 197
  • [5] A passive decay heat removal system for emergency draining tanks of molten salt reactors
    Wang, Shisheng
    Massone, Mattia
    Rineiski, Andrei
    Merle-Lucotte, E.
    Laureau, A.
    Gerardin, D.
    Heuer, D.
    Allibert, M.
    NUCLEAR ENGINEERING AND DESIGN, 2019, 341 : 423 - 431
  • [6] The study of passive cooling system assisted with separate heat pipe for decay heat removal in spent fuel pool
    Lai, Kun
    Wang, Wen
    Yi, Chongchong
    Kuang, Yiwu
    Ye, Cheng
    ANNALS OF NUCLEAR ENERGY, 2018, 111 : 523 - 535
  • [7] A SCALING ANALYSIS FOR A GENERAL PASSIVE HEAT REMOVAL SYSTEM
    Li Wei
    Qi Zhenfeng
    Guo Qiang
    Yuan Yidan
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 6A, 2018,
  • [8] CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor
    Lee, Kwon-Yeong
    Yoon, Hyun-Gi
    Park, Dong Kyou
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2017, 2017
  • [9] Impact of power density profile on passive decay heat removal in prismatic HTGR
    Sambuu, Odmaa
    Obara, Toru
    ANNALS OF NUCLEAR ENERGY, 2016, 87 : 23 - 29
  • [10] Experimental Demonstration of Flow Diodes Applicable to a Passive Decay Heat Removal System for Sodium-Cooled Reactors
    Chikazawa, Yoshitaka
    Aizawa, Kousuke
    Shiraishi, Tadashi
    Sakata, Hideyuki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2009, 46 (04) : 321 - 330