Influence of stems and metaphyseal sleeve on primary stability of cementless revision tibial trays used to reconstruct AORI IIB defects

被引:10
作者
Awadalla, Maged [1 ]
Al-Dirini, Rami M. A. [1 ]
O'Rourke, Dermot [1 ]
Solomon, Lucian B. [2 ,3 ]
Heldreth, Mark [4 ]
Rullkoetter, Paul [5 ]
Taylor, Mark [1 ]
机构
[1] Flinders Univ S Australia, Coll Sci & Engn, Med Device Res Inst, Bedford Pk, SA, Australia
[2] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Adelaide, SA, Australia
[3] Univ Adelaide, Ctr Orthopaed & Trauma Res, Adelaide, SA, Australia
[4] DePuy Synthes Inc, Joint Reconstruct, Warsaw, IN USA
[5] Univ Denver, Dept Mech & Mat Engn, Denver, CO USA
关键词
revision; metaphyseal-sleeve; AORI-IIB; Tibia; FEA; TOTAL KNEE ARTHROPLASTY; TANTALUM FEMORAL CONES; FINITE-ELEMENT; BONE LOSS; FIXATION; TITANIUM; INGROWTH; TISSUE;
D O I
10.1002/jor.24232
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metaphyseal augments, such as sleeves, have been introduced to augment the fixation of revision total knee replacement (rTKR) components, and can be used with or without a stem. The effect of sleeve size in combination with stems on the primary stability and load transfer of a rTKR implant in AORI type IIB defects where the defect involves both condyles are poorly understood. The aim of this study was to examine the primary stability of revision tibial tray augmented with a sleeve in an AORI type IIB defect which involves both condyles with loss of cortical and cancellous bone. Finite element models were generated from computed tomography (CT) scans of nine individuals. All the bones used in the study had an AORI type IIB defect. The cohort included eight females (mean weight: 64 kg, height: 1.6 m). Material properties were sampled from CT data and assigned to the FE model. Joint contact forces for level gait, stair descent, and squat were applied. Stemless sleeved implants under various loading conditions were shown to have adequate primary stability in all AORI type IIB defects investigated. Adding a stem only marginally improved the primary stability of the implant but reduced the strain in the metaphysis compared to stemless implants. Once good initial mechanical stability was established with a sleeve, there was no benefit, in terms of primary stability or bone strains, from increasing sleeve size. This study suggests that metaphyseal sleeves, without a stem, can provide the required primary stability required by a rTKR tibial implant, to reconstruct an AORI type IIB defect. (c) 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res
引用
收藏
页码:1033 / 1041
页数:9
相关论文
共 53 条
  • [1] Finite element modelling of primary hip stem stability: The effect of interference fit
    Abdul-Kadir, Mohammed Rafiq
    Hansen, Ulrich
    Klabunde, Ralf
    Lucas, Duncan
    Amis, Andrew
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (03) : 587 - 594
  • [2] Metal metaphyseal sleeves in revision total knee replacement
    Agarwal, S.
    Azam, A.
    Morgan-Jones, R.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (12) : 1640 - 1644
  • [3] Cementless Metaphyseal Sleeves Used for Large Tibial Defects in Revision Total Knee Arthroplasty
    Alexander, Gerald E.
    Bernasek, Thomas L.
    Crank, Richard L.
    Haidukewych, George J.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (04) : 604 - 607
  • [4] Influence of varying stem and metaphyseal sleeve size on the primary stability of cementless revision tibial trays used to reconstruct AORI IIA defects. A simulation study
    Awadalla, Maged
    Al-Dirini, Rami M. A.
    O'Rourke, Dermot
    Solomon, Lucian B.
    Heldreth, Mark
    Taylor, Mark
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (07) : 1876 - 1886
  • [5] Use of Stepped Porous Titanium Metaphyseal Sleeves for Tibial Defects in Revision Total Knee Arthroplasty: Short Term Results
    Barnett, Steven L.
    Mayer, Ryan R.
    Gondusky, Joseph S.
    Choi, Leera
    Patel, Jay J.
    Gorab, Robert S.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (06) : 1219 - 1224
  • [6] Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
    Bayraktar, HH
    Morgan, EF
    Niebur, GL
    Morris, GE
    Wong, EK
    Keaveny, TM
    [J]. JOURNAL OF BIOMECHANICS, 2004, 37 (01) : 27 - 35
  • [7] Tibial component fixation in total knee arthroplasty - A comparison of pegged and stemmed designs
    Bertin, Kim C.
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (05) : 670 - 678
  • [8] Principles of revision total knee arthroplasty
    Bourne, RB
    Crawford, HA
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (02) : 331 - +
  • [9] Revision total knee arthroplasty by impaction bone grafting
    Bradley, GW
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (371) : 113 - 118
  • [10] Statistical modelling of the whole human femur incorporating geometric and material properties
    Bryan, Rebecca
    Mohan, P. Surya
    Hopkins, Andrew
    Galloway, Francis
    Taylor, Mark
    Nair, Prasanth B.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2010, 32 (01) : 57 - 65