Three-year outcome of the covered endovascular reconstruction of the aortic bifurcation technique for aortoiliac occlusive disease

被引:73
作者
Taeymans, Kim [1 ]
Jebbink, Erik Groot [2 ,4 ]
Holewijn, Suzanne [2 ]
Martens, Jasper M. [3 ]
Versluis, Michel [4 ]
Goverde, Peter C. J. M. [1 ]
Reijnen, Michel M. P. J. [2 ]
机构
[1] Vasc Clin ZNA, Dept Vasc Surg, Antwerp, Belgium
[2] Rijnstate Hosp, Dept Surg, Wagnerlaan 55, NL-6815 AD Arnhem, Netherlands
[3] Rijnstate Hosp, Dept Radiol, Arnhem, Netherlands
[4] Univ Twente, MIRA Inst Biomed Technol & Tech Med, Phys Fluids Grp, Enschede, Netherlands
关键词
KISSING STENTS; CERAB TECHNIQUE; MORTALITY; STANDARDS; SOCIETY; SURGERY; BYPASS;
D O I
10.1016/j.jvs.2017.09.015
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The objective of this study was to demonstrate the 3-year outcome of the covered endovascular reconstruction of the aortic bifurcation (CERAB) technique for the treatment of extensive aortoiliac occlusive disease (AIOD). Methods: Between February 2009 and July 2016, all patients treated with the CERAB technique for AIOD were identified in the local databases of two centers and analyzed. Demographics and lesion characteristics were scored. Follow-up consisted of clinical assessment, duplex ultrasound, and ankle-brachial indices. Patency rates and clinically driven target lesion revascularization were calculated by Kaplan-Meier analysis. Results: Of 130 patients (69 male and 61 female) treated, 68% were diagnosed with intermittent claudication and 32% suffered from critical limb ischemia. The majority (89%) were TransAtlantic Inter-Society Consensus II D lesions, and the remaining were B and C lesions (both 5%). Median follow-up was 24 months (range, 0-67 months). The technical success rate was 97%, and 67% of cases were performed completely percutaneously. The ankle-brachial index improved significantly from 0.65 6 0.22 preoperatively to 0.88 6 0.15 after the procedure. The 30-day minor and major complication rate was 33% and 7%. The median hospital stay was 2 days (range, 1-76 days). At 1 year and 3 years of follow-up, 94% and 96% of the patients clinically improved at least one Rutherford category (2% and 0% unchanged, 4% and 4% worsened). Limb salvage rate was 98% at 1 year and 97% at 3 years of follow-up. Primary, primary assisted, and secondary patency was 86%, 91%, and 97% at 1 year; 84%, 89%, and 97% at 2 years; and 82%, 87%, and 97% at 3 years. Freedom from clinically driven target lesion revascularization was 87% at 1-year follow-up and 86% at both 2-year and 3-year follow-up. Conclusions: The CERAB technique is a safe and feasible technique for the treatment of extensive AIOD with good 3-year results regarding patency and clinical improvement.
引用
收藏
页码:1438 / 1447
页数:10
相关论文
共 29 条
  • [1] Hemodynamic analysis of edge stenosis in peripheral artery stent grafts
    Al-Hakim, R.
    Lee, E. W.
    Kee, S. T.
    Seals, K.
    Varghese, B.
    Chien, A.
    Quirk, M.
    McWilliams, J.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2017, 98 (10) : 729 - 735
  • [2] Mortality and complications after aortic bifurcated bypass procedures for chronic aortoiliac occlusive disease
    Bredahl, Kim
    Jensen, Leif Panduro
    Schroeder, Torben V.
    Sillesen, Henrik
    Nielsen, Henrik
    Eiberg, Jonas P.
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 62 (01) : 75 - 82
  • [3] Blood flow velocity prediction in aorto-iliac stent grafts using computational fluid dynamics and Taguchi method
    Chong, Albert Y.
    Doyle, Barry J.
    Jansen, Shirley
    Ponoshi, Stefan
    Cisonni, Julien
    Sun, Zhonghua
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 84 : 235 - 246
  • [4] Initial Experience With Covered Endovascular Reconstruction of the Aortic Bifurcation in Conjunction With Chimney Grafts
    Dijkstra, Martijn L.
    Goverde, Peter C. J. M.
    Holden, Andrew
    Zeebregts, Clark J.
    Reijnen, Michel M. P. J.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (01) : 19 - 24
  • [5] A comparison between aortobifemoral bypass and aortoiliac kissing stents in patients with complex aortoiliac obstructive disease
    Dorigo, Walter
    Piffaretti, Gabriele
    Benedetto, Filippo
    Tarallo, Antonino
    Castelli, Patrizio
    Spinelli, Francesco
    Fargion, Aaron
    Pratesi, Carlo
    [J]. JOURNAL OF VASCULAR SURGERY, 2017, 65 (01) : 99 - 107
  • [6] Goverde PCJM, 2013, J CARDIOVASC SURG, V54, P383
  • [7] Does stent overlap influence the patency rate of aortoiliac kissing stents?
    Greiner, A
    Mühlthaler, H
    Neuhauser, B
    Waldenberger, P
    Dessl, A
    Schocke, MFH
    Jaschke, W
    Fraedrich, G
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (06) : 696 - 703
  • [8] Editor's Choice - First Results of the Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) Technique for Aortoiliac Occlusive Disease
    Grimme, F. A. B.
    Goverde, P. C. J. M.
    Verbruggen, P. J. E. M.
    Zeebregts, C. J.
    Reijnen, M. M. P. J.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (05) : 638 - 647
  • [9] Haulon S, 2002, J ENDOVASC THER, V9, P363, DOI 10.1583/1545-1550(2002)009<0363:PROTAB>2.0.CO
  • [10] 2