Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine

被引:30
|
作者
Palanisamy, Selvakumar [1 ]
Ramaraj, Sayee Kannan [2 ]
Chen, Shen-Ming [1 ]
Velusamy, Vijayalakshmi [3 ]
Yang, Thomas C. K. [4 ]
Chen, Tse-Wei [1 ]
机构
[1] Natl Taipei Univ Technol, Electroanal & Bioelectrochem Lab, Dept Chem Engn & Biotechnol, 1,Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[2] Thiagarajar Coll, PG & Res Dept Chem, Madurai 09, Tamil Nadu, India
[3] Manchester Metropolitan Univ, Sch Engn, Div Elect & Elect Engn, Manchester M1 5GD, Lancs, England
[4] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, 1,Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
关键词
Electrochemical sensor; Differential pulse voltammetry; Conductive polymer: nanocomposite; FESEM; FTIR; Water analysis; SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; DIHYDROXYBENZENE ISOMERS; HYDROQUINONE; POLY(MELAMINE); NANOCOMPOSITE; RESORCINOL;
D O I
10.1007/s00604-017-2073-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe an voltammetric catechol (CC) assay based on the use of a glassy carbon electrode (GCE) modified with a composite consisting of graphene oxide and polymelamine (GO/PM). The modified GCE was characterized by field emission scanning electron microscopy, elemental analysis, Raman spectroscopy and FTIR. Cyclic voltammetry reveals a well-defined response to CC, with an oxidation peak current that is distinctly enhanced compared to electrodes modified with GO or PM only. The combined synergetic activity of GO and PM in the composite also results in a lower oxidation potential. Differential pulse voltammetry (DPV) shows a response that is linear in the 0.03 to 138 mu M CC concentration range. The detection limit is 8 nM, and the sensitivity is 0.537 mu Aai...mu M(-1)ai...cm(-2). The sensor is selective for CC even in the presence of potentially interfering compounds including hydroquinone, resorcinol and dopamine. The modified GCE is highly reproducible, stable, sensitive, and shows an excellent practicability for detection of CC in water samples.
引用
收藏
页码:1051 / 1057
页数:7
相关论文
共 50 条
  • [1] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Selvakumar Palanisamy
    Sayee Kannan Ramaraj
    Shen-Ming Chen
    Vijayalakshmi Velusamy
    Thomas C. K. Yang
    Tse-Wei Chen
    Microchimica Acta, 2017, 184 : 1051 - 1057
  • [2] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [3] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984
  • [4] Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide
    Lisnund, Sireerat
    Blay, Vincent
    Chansaenpak, Kantapat
    Pinyou, Piyanut
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7214 - 7227
  • [5] Voltammetric determination of sumatriptan based on a graphene/gold nanoparticles/Nafion composite modified glassy carbon electrode
    Sanghavi, Bankim J.
    Kalambate, Pramod K.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    TALANTA, 2014, 120 : 1 - 9
  • [6] Voltammetric determination of nitric oxide using a glassy carbon electrode modified with a nanohybrid consisting of myoglobin, gold nanorods, and reduced graphene oxide
    Ab Rahman Marlinda
    Alagarsamy Pandikumar
    Subramaniam Jayabal
    Norazriena Yusoff
    Abu Bakar Suriani
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 3077 - 3085
  • [7] Voltammetric determination of nitric oxide using a glassy carbon electrode modified with a nanohybrid consisting of myoglobin, gold nanorods, and reduced graphene oxide
    Marlinda, Ab Rahman
    Pandikumar, Alagarsamy
    Jayabal, Subramaniam
    Yusoff, Norazriena
    Suriani, Abu Bakar
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (11) : 3077 - 3085
  • [8] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Dai, Hongxiu
    Wang, Nan
    Wang, Donglei
    Zhang, Xiaomei
    Ma, Houyi
    Lin, Meng
    MICROCHIMICA ACTA, 2016, 183 (11) : 3053 - 3059
  • [9] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Hongxiu Dai
    Nan Wang
    Donglei Wang
    Xiaomei Zhang
    Houyi Ma
    Meng Lin
    Microchimica Acta, 2016, 183 : 3053 - 3059
  • [10] Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Rani, T. Shobha
    Ganesh, P. S.
    Raj, Y. Paul
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 746 - 752