The measurement of body segment inertial parameters using dual energy X-ray absorptiometry

被引:85
作者
Durkin, JL
Dowling, JJ [1 ]
Andrews, DM
机构
[1] Univ Windsor, Fac Human Kinet, Windsor, ON N8B 3P4, Canada
[2] McMaster Univ, Dept Kinesiol, Hamilton, ON L8S 4K1, Canada
关键词
DXA; body segment parameters; moment of inertia; mass; centre of mass location;
D O I
10.1016/S0021-9290(02)00227-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Accurate body segment parameter (BSP) information is required for dynamic analyses of motion and the current methods available for obtaining these BSPs have been criticized. The purpose of this study was to determine whether dual energy X-ray absorptiometry (DXA) could accurately measure the BSPs of scanned objects and thus be used as a tool for measuring the BSPs of human subjects. Whole body mass (WBM) of 11 males was measured from a DXA scan and the values were compared to criterion scale-measured values by calculating the mean percent error. Two objects (plastic cylinder, human cadaver leg) were also scanned and DXA measurements of mass, length, centre of mass location (CM) and moment of inertia about the centre of mass (I-CM) were made using custom software. Criterion BSP measurements were then made and compared to DXA BSP values by calculating the percent error. Criterion I-CM measurements of the two objects were made using a pendulum technique and a second criterion I-CM calculation was made for the cylinder using a geometric formula. A mean percent error of -1.05% +/- 1.32% was found for WBM measurements of the human subjects. Errors for the cylinder and cadaver leg were under 3.2% for all BSPs except for I-CM when DXA was compared to the pendulum method (14.3% and 8.2% for cylinder and leg, respectively). The errors between DXA and the pendulum method were attributed to uncertainty in the pendulum technique (J. Biomech. 2002, in Review). I-CM error of the cylinder when DXA was compared to the geometric calculation was 2.63%. This error, combined with the low errors for all other BSPs, indicated that DXA can be used as a simple and accurate means of obtaining direct BSP information on living humans. (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:1575 / 1580
页数:6
相关论文
共 16 条
  • [1] [Anonymous], TR6970 AMRL WRIGHT P
  • [2] [Anonymous], 1955, 55159 WADC WRIGHT PA
  • [3] BRAUNE W, 1989, 138452 ATI NAT TECHN
  • [4] CHANDLER RF, 1975, TR74137 ARML
  • [5] Segment inertial properties of Chinese adults determined from magnetic resonance imaging
    Cheng, CK
    Chen, HH
    Chen, CS
    Lee, CL
    Chen, CY
    [J]. CLINICAL BIOMECHANICS, 2000, 15 (08) : 559 - 566
  • [6] CHILIBECK P, 1994, CAN ASSOC RADIOL J, V45, P297
  • [7] Davis R.B., 1994, GAIT POSTURE, V2, P58
  • [8] DOWLING JJ, 2002, UNPUB J BIOMECHANICS
  • [9] DURKIN JL, 1998, THESIS MCMASTER U HA
  • [10] EVALUATION OF CROSS-SECTIONAL GEOMETRY AND MASS DENSITY DISTRIBUTIONS OF HUMANS AND LABORATORY-ANIMALS USING COMPUTERIZED-TOMOGRAPHY
    HUANG, HK
    SUAREZ, FR
    [J]. JOURNAL OF BIOMECHANICS, 1983, 16 (10) : 821 - 832