A high efficiency coaxial pulse tube cryocooler operating at 60 K

被引:11
|
作者
Wang, Nailiang [1 ,2 ]
Zhao, Miguang [1 ,2 ]
Ou, Yangyang [1 ,2 ]
Zhu, Qianglong [1 ]
Wei, Lingjiao [1 ]
Chen, Houlei [1 ,2 ]
Cai, Jinghui [1 ,2 ]
Liang, Jingtao [1 ,2 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Space Energy Convers Technol, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Pulse tube cryocooler; Coaxial; Infrared detector; 60; K;
D O I
10.1016/j.cryogenics.2018.05.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
In recent years, improved efficiency of pulse tube cryocoolers has been required by some space infrared detectors and special military applications. Based on this, a high efficiency single-stage coaxial pulse tube cryocooler which operates at 60 K is introduced in this paper. The cryocooler is numerically designed using SAGE, and details of the analysis are presented. The performance of the cryocooler at different input powers ranging from 100 W to 200 W is experimentally tested. Experimental results show that this cryocooler typically provides a cooling power of 7.7 W at 60 K with an input power of 200 W, and achieves a relative Carnot efficiency of around 15%. When the cooling power is around 6 W, the cryocooler achieves the best relative Carnot efficiency of around 15.9% at 60 K, which is the highest efficiency ever reported for a coaxial pulse tube cryocooler.
引用
收藏
页码:48 / 50
页数:3
相关论文
共 50 条
  • [2] Numerical and experimental investigation of 12 W/60 K high-efficiency coaxial pulse tube cryocooler
    Li, Yanen
    Wang, Nailiang
    Zhao, Miguang
    Tang, Qingjun
    Xun, Yuqiang
    CRYOGENICS, 2024, 143
  • [3] A high efficiency Stirling/pulse tube hybrid cryocooler operating at 35 K/85 K
    Liu, Biqiang
    Jiang, Zhenhua
    Ying, Kongkuai
    Zhu, Haifeng
    Liu, Shaoshuai
    Wen, Fengshuo
    Wu, Yinong
    Dong, Deping
    CRYOGENICS, 2019, 101 : 137 - 140
  • [4] A high-efficiency coaxial pulse tube cryocooler with 500 W cooling capacity at 80 K
    Hu, J. Y.
    Zhang, L. M.
    Zhu, J.
    Chen, S.
    Luo, E. C.
    Dai, W.
    Li, H. B.
    CRYOGENICS, 2014, 62 : 7 - 10
  • [5] Numerical and experimental investigation of 12 W/60 K high-efficiency coaxial pulse tube cryocooler (vol 143, 10394, 2024)
    Li, Yanen
    Wang, Nailiang
    Zhao, Miguang
    Tang, Qingjun
    Xun, Yuqiang
    CRYOGENICS, 2025, 146
  • [6] Development of a coaxial pulse tube cryocooler for 77 K cooling
    Olson, J. R.
    Moore, M.
    Evtimov, B.
    Jensen, J.
    Nast, T. C.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 1967 - +
  • [7] A lightweight high-capacity pulse tube cryocooler operating at 80 K
    Wang, Nailiang
    Tang, Qingjun
    Xun, Yuqiang
    Liang, Menglin
    Zhao, Miguang
    Chen, Houlei
    Liang, Jingtao
    CRYOGENICS, 2024, 138
  • [8] 30 K single-stage high frequency coaxial pulse tube cryocooler
    Technical Institute of Physics and Chemistry, CAS, Beijing 100190, China
    不详
    Kung Cheng Je Wu Li Hsueh Pao, 2009, 5 (734-736):
  • [9] A High Efficiency Coaxial Pulse Tube Cryocooler for Cooling Medium-Wave Infrared Detectors
    Wei, Lingjiao
    Wang, Nailiang
    Zhao, Miguang
    Liang, Jingtao
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2021, 203 (3-4) : 362 - 368
  • [10] A High Efficiency Coaxial Pulse Tube Cryocooler for Cooling Medium-Wave Infrared Detectors
    Lingjiao Wei
    Nailiang Wang
    Miguang Zhao
    Jingtao Liang
    Journal of Low Temperature Physics, 2021, 203 : 362 - 368