Evaluation of the thermal performance of an earth-to-air heat exchanger (EAHE) in a harmonic thermal environment

被引:77
作者
Yang, Dong
Guo, Yuanhao
Zhang, Jinpeng
机构
[1] Chongqing Univ, Key Lab Three Gorges Reservoir Reg Ecoenvironm, Minist Educ, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
EAHE; Harmonic thermal environment; Phase shifting; Cooling/heating potential; Excess fluctuating temperature; Analytical solution; VENTILATION; BUILDINGS; ENERGY; PIPE; TEMPERATURE; GREENHOUSE; SYSTEMS; STACK;
D O I
10.1016/j.enconman.2015.11.050
中图分类号
O414.1 [热力学];
学科分类号
摘要
The earth-to-air heat exchanger (EAHE) is a low-energy device used to improve the thermal condition of buildings, which is filled with the air directed from the outside and surrounded by the soil. The temperatures of both the air and soil are periodically fluctuating, leading to the EAHEs working in a harmonic thermal environment. However, most of the previous theoretical studies investigated the performance of EAHEs by ways of static and steady-state models, paying insufficient attention to the temperature phase shifting and fluctuation attenuation effects. The main purpose of this work is to develop an approach to predict the performance of EAHE subjected to harmonic thermal environments. The harmonic temperature signals transmitted from both the pipe inlet and the ground surface are incorporated in the model by means of the 'excess fluctuating temperature'. The amplitude dampening and phase shifting of the EAHE air temperature for both annually and daily fluctuating cycles are derived as explicit expressions. The analytical results are validated against numerical simulations. The model is applied in a hot-summer/cold-winter region. Results indicate that a deep-buried EAHE pipe can reduce the air temperature by 7 degrees C on a summer day. The maximum cooling or heating capacities occur in spring/summer or autumn/winter transitional seasons. The use of an EAHE pipe can create a 3000-W cooling or heating capacity. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:184 / 194
页数:11
相关论文
共 34 条
[1]   Stack ventilation in multi-storey atrium buildings: A dimensionless design approach [J].
Acred, Andrew ;
Hunt, Gary R. .
BUILDING AND ENVIRONMENT, 2014, 72 :44-52
[2]   The cooling potential of earth-air heat exchangers for domestic buildings in a desert climate [J].
Al-Ajmi, F ;
Loveday, DL ;
Hanby, VI .
BUILDING AND ENVIRONMENT, 2006, 41 (03) :235-244
[3]  
[Anonymous], 1997, PASSIVE COOLING BUIL
[4]  
Aschehoug O, 2009, IEA ECBCS ANNEX 44 2
[5]   Performance analysis of earth-pipe-air heat exchanger for summer cooling [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2010, 42 (05) :645-648
[6]   Performance analysis of an earth-to-air heat exchanger assisted by a wind tower for passive cooling of buildings in arid and hot climate [J].
Benhammou, M. ;
Draoui, B. ;
Zerrouki, M. ;
Marif, Y. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 91 :1-11
[7]   TEMPERATURE DISTRIBUTION INSIDE GROUND FOR VARIOUS SURFACE CONDITIONS [J].
BHARADWAJ, SS ;
BANSAL, NK .
BUILDING AND ENVIRONMENT, 1981, 16 (03) :183-192
[8]   Experimental and analytical studies of earth-air heat exchanger (EAHE) systems in India: A review [J].
Bisoniya, Trilok Singh ;
Kumar, Anil ;
Baredar, Prashant .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 19 :238-246
[9]   Analytical interpretation of the local thermal non-equilibrium condition of porous media imbedded in tube heat exchangers [J].
Dehghan, Maziar ;
Jamal-Abad, Milad Tajik ;
Rashidi, Saman .
ENERGY CONVERSION AND MANAGEMENT, 2014, 85 :264-271
[10]   Modeling and parametric studies for thermal performance of an earth to air heat exchanger integrated with a greenhouse [J].
Ghosal, MK ;
Tiwari, GN .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (13-14) :1779-1798