Evaluation of the trueness of serum alkaline phosphatase measurement in a group of Italian laboratories

被引:22
作者
Braga, Federica [1 ,2 ]
Frusciante, Erika [3 ]
Infusino, Ilenia [3 ]
Aloisio, Elena [3 ]
Guerra, Elena [4 ]
Ceriotti, Ferruccio [4 ]
Panteghini, Mauro [3 ]
机构
[1] UOC Patol Clin, ASST Fatebenefratelli Sacco, Via GB Grassi 74, I-20157 Milan, Italy
[2] Univ Milan, Metrol Traceabil Lab Med CIRME, Milan, Italy
[3] Univ Milan, Res Ctr Metrol Traceabil Lab Med CIRME, Milan, Italy
[4] Hosp San Raffaele, Clin Lab Serv, Milan, Italy
关键词
alkaline phosphatase; external quality assessment; trueness; METROLOGICAL TRACEABILITY; BIOLOGICAL VARIATION; ENZYMES; STANDARDIZATION; IMPLEMENTATION;
D O I
10.1515/cclm-2016-0605
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
引用
收藏
页码:E47 / E50
页数:4
相关论文
共 11 条
[1]   Performance criteria for combined uncertainty budget in the implementation of metrological traceability [J].
Braga, Federica ;
Infusino, Ilenia ;
Panteghini, Mauro .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (06) :905-912
[2]   Verification of in vitro medical diagnostics (IVD) metrological traceability: Responsibilities and strategies [J].
Braga, Federica ;
Panteghini, Mauro .
CLINICA CHIMICA ACTA, 2014, 432 :55-61
[3]  
Ceriotti F, 2005, BIOCHIM CLIN, V29, P486
[4]   Trueness and comparability assessment of widely used assays for 5 common enzymes and 3 electrolytes [J].
Goossens, Kenneth ;
Van Uytfanghe, Katleen ;
Thienpont, Linda M. .
CLINICA CHIMICA ACTA, 2015, 442 :44-45
[5]   Standardization in clinical enzymology: a challenge for the theory of metrological traceability [J].
Infusino, Ilenia ;
Schumann, Gerhard ;
Ceriotti, Ferruccio ;
Panteghini, Mauro .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (03) :301-307
[6]  
Pagani F, 2001, CLIN CHEM, V47, P355
[7]   BIOLOGICAL VARIATION IN BONE-DERIVED BIOCHEMICAL MARKERS IN SERUM [J].
PANTEGHINI, M ;
PAGANI, F .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1995, 55 (07) :609-616
[8]  
PANTEGHINI M, 1989, CLIN CHEM, V35, P180
[9]  
Panteghini M, 2012, CLIN CHEM LAB MED, V50, P1237, DOI [10.1515/CCLM.2011.791, 10.1515/cclm.2011.791]
[10]   IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: Reference procedure for the measurement of catalytic concentration of alkaline phosphatase [J].
Schumann, Gerhard ;
Klauke, Rainer ;
Canalias, Francesca ;
Bossert-Reuther, Steffen ;
Franck, Paul F. H. ;
Gella, F. Javier ;
Jorgensen, Poul J. ;
Kang, Dongchon ;
Lessinger, Jean-Marc ;
Panteghini, Mauro ;
Ceriotti, Ferruccio .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (09) :1439-1446