Effect of region of interest selection and uptake measurement on glomerular filtration rate measured by 99mTc-DTPA scintigraphy in dogs

被引:25
作者
Kampa, N
Wennstrom, U
Lord, P
Twardock, R
Maripuu, E
Eksell, P
Fredriksson, SO
机构
[1] Swedish Univ Agr Sci, Fac Vet Med, Dept Clin Radiol, S-75007 Uppsala, Sweden
[2] Univ Uppsala, Dept Med Phys, S-75105 Uppsala, Sweden
[3] Univ Illinois, Dept Vet Biosci, Urbana, IL 61801 USA
关键词
dog; GFR; Tc-99m-DTPA; gamma camera; renography;
D O I
10.1111/j.1740-8261.2002.tb01022.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Determinations of different methods of measurement of uptake of Tc-99m-DTPA using scintigraphy of glomerular filtration rate (GFR) were made from 29 studies on 10 healthy beagle dogs. GFR was measured by calculating the percentage dose uptake (integral method) and rate of uptake (slope method) of 99mTc-DTPA using manual kidney regions of interest (1101) and automatic kidney and background ROIs at different time periods of the uptake phase. These results were compared using linear regression analysis to the GFR obtained from Tc-99m-DTPA plasma clearance using multiple blood samples. The best correlation coefficient between percentage DTPA uptake and GFR by DTPA clearance (r = 0.84, P < 0.001) was derived from time intervals between 30s-120s with a perirenal background ROI at 1 or 2 pixels out from the kidney ROI using automatic kidney ROI at 20% threshold. With the slope method, the best correlation coefficient (r = 0.85, P < 0.001) was obtained from time intervals between 30s-peak with the background ROI at 2 pixels out from the kidney ROI using automatic ROI at 35% threshold. The offset was higher, and the correlation varied more with different ROIs and the method was unreliable at time intervals extending beyond the peak radioactivity. Manual kidney ROIs with automatic background ROIs had slightly lower correlations. With DTPA renography both integral and slope uptake method with automatic kidney and background ROIs are accurate methods to estimate the GFR, but that the integral method is much more stable to variations in ROI size and the duration of the uptake phase of the renogram.
引用
收藏
页码:383 / 391
页数:9
相关论文
共 27 条
[1]  
AWDEH M, 1990, American Journal of Physiologic Imaging, V5, P36
[2]   Comparison between the scintigraphic uptake and plasma clearance of 99mTc-diethylenetriaminepentacetic acid (DTPA) for the evaluation of the glomerular filtration rate in dogs [J].
Barthez, PY ;
Hornof, WJ ;
Cowgill, LD ;
Neal, LA ;
Mickel, P .
VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (05) :470-474
[3]   Effect of sample number and time on determination of plasma clearance of technetium Tc 99m pentetate and orthoiodohippurate sodium I 131 in dogs and cats [J].
Barthez, PY ;
Chew, DJ ;
DiBartola, SP .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2000, 61 (03) :280-285
[4]   Renal nuclear medicine: A review [J].
Daniel, GB ;
Mitchell, SK ;
Mawby, D ;
Sackman, JE ;
Schmidt, D .
VETERINARY RADIOLOGY & ULTRASOUND, 1999, 40 (06) :572-587
[5]  
DANIEL GB, 1996, HDB VET NUCL MED, P18
[7]   A SIMPLE METHOD FOR MEASURING GLOMERULAR-FILTRATION RATE IN DOGS [J].
GLEADHILL, A ;
PETERS, AM ;
MICHELL, AR .
RESEARCH IN VETERINARY SCIENCE, 1995, 59 (02) :118-123
[8]  
GORIS ML, 1976, J NUCL MED, V17, P744
[9]   EVALUATION OF UNILATERAL KIDNEY-FUNCTION IN CHILDREN - A COMPARISON BETWEEN RENOGRAPHY AND SEPARATE CLEARANCE [J].
GRANERUS, G ;
AURELL, M ;
BJURE, J ;
HAUGSTVEDT, S ;
LJUNG, B .
SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1980, 14 (03) :263-267
[10]  
GRANERUS G, 2000, NJURARNA OVRE URINVA, P78