A direct filtered back-projection reconstruction method for inverse geometry CT without gridding: a simulation study

被引:2
作者
Jiang, Xiao [1 ]
Zhu, Lei [2 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Engn & Appl Phys, Hefei 230026, Anhui, Peoples R China
来源
MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING | 2019年 / 10948卷
基金
中国国家自然科学基金;
关键词
inverse geometry CT; filtered backprojection; offset source; FOURIER INVERSION; ALGORITHM; SYSTEM;
D O I
10.1117/12.2507356
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inverse geometry computed tomography (IGCT) uses a small detector and a set of widely distributed x-ray sources. Standard filtered backprojection (FBP) reconstruction for a conventional CT geometry cannot be directly used in IGCT, due to data truncation and redundancy of the sinograms acquired by different sources. Current IGCT algorithms use gridding or iterations during reconstruction, leading to degraded spatial resolution or increased computational cost. In this work, we propose a direct FBP reconstruction method for IGCT without gridding. A reconstruction algorithm is first derived for a full-size sinogram acquired by a single source with a known offset distance to the central line passing through the rotational axis and perpendicular to the detector. A weighting scheme is then developed on the projections to remove the data redundancy of different sinograms acquired by different sources. The final reconstruction is obtained as the summation of CT images reconstructed from different sources, in a form of FBP on weighted projections. The performance of the proposed algorithm is evaluated via simulation studies on the Shepp-Logan phantom. Results show that our algorithm substantially improves the image spatial resolution over the gridding method. The spatial resolution increases by 32.08% and 23.26% at 50% and 10% of the modulation transfer function, respectively. Finally, we demonstrate the advantages of volumetric IGCT compared with circular cone-beam CT in a pilot study.
引用
收藏
页数:7
相关论文
共 18 条
  • [1] A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array
    Baek, Jongduk
    De Man, Bruno
    Uribe, Jorge
    Longtin, Randy
    Harrison, Daniel
    Reynolds, Joseph
    Neculaes, Bogdan
    Frutschy, Kristopher
    Inzinna, Louis
    Caiafa, Antonio
    Senzig, Robert
    Pelc, Norbert J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05) : 1189 - 1202
  • [2] Direct two-dimensional reconstruction algorithm for an inverse-geometry CT system
    Baek, Jongduk
    Pelc, Norbert J.
    [J]. MEDICAL PHYSICS, 2009, 36 (02) : 394 - 401
  • [3] Beque D., 2007, MED IMAGING 2007 PHY
  • [4] De Man B., 2007, MED IMAGING 2007 PHY
  • [5] De Man B., 2007, NUCL SCI S C REC 200
  • [6] Multisource inverse-geometry CT. Part I. System concept and development
    De Man, Bruno
    Uribe, Jorge
    Baek, Jongduk
    Harrison, Dan
    Yin, Zhye
    Longtin, Randy
    Roy, Jaydeep
    Waters, Bill
    Wilson, Colin
    Short, Jonathan
    Inzinna, Lou
    Reynolds, Joseph
    Neculaes, V. Bogdan
    Frutschy, Kristopher
    Senzig, Bob
    Pelc, Norbert
    [J]. MEDICAL PHYSICS, 2016, 43 (08) : 4607 - 4616
  • [7] Exact and approximate rebinning algorithms for 3-D PET data
    Defrise, M
    Kinahan, PE
    Townsend, DW
    Michel, C
    Sibomana, M
    Newport, DF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 145 - 158
  • [8] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [9] SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING
    JACKSON, JI
    MEYER, CH
    NISHIMURA, DG
    MACOVSKI, A
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 473 - 478
  • [10] Fourier rebinning algorithm for inverse geometry CT
    Mazin, Samuel R.
    Pelc, Norbert J.
    [J]. MEDICAL PHYSICS, 2008, 35 (11) : 4857 - 4862