Model-free control for frequency response support in microgrids utilizing wind turbines 1

被引:17
作者
Park, Byungkwon [1 ]
Zhang, Yichen [2 ]
Olama, Mohammed [1 ]
Kuruganti, Teja [1 ]
机构
[1] Oak Ridge Natl Lab, Computat Sci & Engn Div, POB 2009, Oak Ridge, TN 37831 USA
[2] Argonne Natl Lab, Energy Syst Div, Lemont, IL 60439 USA
关键词
Microgrids; Model-free control; Model reference concept; Inertia emulation; Primary frequency control; INERTIAL RESPONSE; FRAMEWORK;
D O I
10.1016/j.epsr.2021.107080
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Islanded microgrids integrated with renewable energy resources bring additional challenges to the primary frequency control due to their power-electronic interfaced generations. Developing an efficient control strategy for inertia emulation and frequency response support of microgrids is becoming an important issue. Wind turbine dynamics, however, will degrade the emulated inertial and primary responses with most traditional control strategies. On the other hand, compensation methods often require the knowledge of system models at the design stage and state estimation for feedback once deployed online. To overcome these challenges, this paper explores a model-free control (MFC) strategy to emulate the desired inertia and support the frequency response of a diesel-wind microgrid system. The proposed MFC strategy utilizes a model reference concept to obtain guaranteed inertial response and improve the frequency response of microgrids. This work considers different control strategies with different operating points. The proposed controller is implemented and verified using the modified 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results demonstrate the improved frequency response by precisely emulating the desired inertia using the MFC strategy.
引用
收藏
页数:10
相关论文
共 37 条
  • [11] Fliess M., 2013, P 52 IEEE C DEC CONT
  • [12] Model-free control
    Fliess, Michel
    Join, Cedric
    [J]. INTERNATIONAL JOURNAL OF CONTROL, 2013, 86 (12) : 2228 - 2252
  • [13] Non-linear estimation is easy
    Fliess, Michel
    Join, Cedric
    Sira-Ramirez, Hebertt
    [J]. INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2008, 4 (01) : 12 - 27
  • [14] Gao H., 2008, IEEE T AUTOMAT CONTR, V53, P8
  • [15] Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids
    Hatipoglu, Kenan
    Olama, Mohammed
    Xue, Yaosuo
    [J]. ENERGIES, 2020, 13 (15)
  • [16] Huang S.H., 2009, P IEEE POW EN SOC GE
  • [17] Join C, 2013, CONF CONTR FAULT-TOL, P554, DOI 10.1109/SysTol.2013.6693811
  • [18] Krause P, 2013, ANALYSIS OF ELECTRIC MACHINERY AND DRIVE SYSTEMS, 3RD EDITION, P1, DOI 10.1002/9781118524336
  • [19] Kundur P, 1994, POWER SYSTEM STABILI
  • [20] A model-free control strategy for an experimental greenhouse with an application to fault accommodation
    Lafont, Frederic
    Balmat, Jean-Francois
    Pessel, Nathalie
    Fliess, Michel
    [J]. COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2015, 110 : 139 - 149