Between-week reliability of the cervical range of motion (CROM) device for upper cervical rotation

被引:10
作者
Gugliotti, Mark [1 ]
Tau, Jessica [1 ]
Gallo, Kelly [1 ]
Sagliocca, Natalina [1 ]
Horan, Michael [1 ]
Sussman, Nicole [1 ]
Wisnewski, Robert [1 ]
机构
[1] New York Inst Technol, Dept Phys Therapy, Old Westbury, NY 11568 USA
关键词
cervical spine; clinical tool; range of motion; upper cervical; rotation; DIAGNOSTIC VALIDITY; SPINE;
D O I
10.1080/10669817.2020.1805691
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: The Cervical Range of Motion (CROM) device is a valid and reliable clinical tool used to measure full cervical rotation, however, its reliability for measuring upper cervical rotation is unknown. Objectives: Assess between-week test-retest reliability of the CROM device in measuring upper cervical rotation Method: Thirty students participated in this test-retest reliability study. The CROM device was used to measure left and right cervical rotation in both a seated neutral and fully flexed head-neck position. Interclass correlation coefficient (ICC) was calculated for all motions. Measurement error was determined using standard error of measurement (SEM) and minimal detectable change (MDC). Results: The CROM device demonstrated moderate to good reliability (ICCs 0.65-0.9) of full and upper cervical rotation. The SEMs and MDCs of this study are small and suggest that the chance of repeated measurement error was relatively minimal for the between-week trials. Conclusions: The CROM device is a reliable outcome tool for measuring upper cervical rotation. The clinical implications of these findings suggest that therapists can utilize the CROM device to more completely examine all planes of upper and full cervical mobility. It may also assist in identifying upper cervical ROM limitations associated with underlying cervical pathology or motion dysfunction.
引用
收藏
页码:176 / 180
页数:5
相关论文
共 25 条
[1]   Measuring range of active cervical rotation in a position of full head flexion using the 3D Fastrak measurement system: an intra-tester reliability study [J].
Amiri, M ;
Jull, G ;
Bullock-Saxton, J .
MANUAL THERAPY, 2003, 8 (03) :176-179
[2]   Validity and Between-Day Reliability of the Cervical Range of Motion (CROM) Device [J].
Audette, Isabel ;
Dumas, Jean-Pierre ;
Cote, Julie N. ;
De Serres, Sophie J. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2010, 40 (05) :318-323
[3]  
Blanpied Peter R, 2017, J Orthop Sports Phys Ther, V47, pA1, DOI 10.2519/jospt.2017.0302
[4]   Biomechanics of the cervical spine. I: Normal kinematics [J].
Bogduk, N ;
Mercer, S .
CLINICAL BIOMECHANICS, 2000, 15 (09) :633-648
[5]  
Clarkson HM., 2013, MUSCULOSKELETAL ASSE, V3rd, P419
[6]  
Dhimitri K., 1998, J MAN MANIP THER, V6, P31, DOI [10.1179/jmt.1998.6.1.31, DOI 10.1179/JMT.1998.6.1.31]
[7]  
Ernst M., 2006, MAN THER, V25, pE70
[8]   Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain [J].
Fletcher, James P. ;
Bandy, William D. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2008, 38 (10) :640-645
[9]   The flexion-rotation test and active cervical mobility - A comparative measurement study in cervicogenic headache [J].
Hall, T ;
Robinson, K .
MANUAL THERAPY, 2004, 9 (04) :197-202
[10]   Intertester reliability and diagnostic validity of the cervical flexion-rotation test [J].
Hall, Toby M. ;
Robinson, Kim W. ;
Fujinawa, Osamu ;
Akasaka, Kiyokazu ;
Pyne, Elizabeth A. .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2008, 31 (04) :293-300