In vitro comparison of resonance frequency analysis devices to evaluate implant stability of narrow diameter implants at varying drilling speeds in dense artificial bone blocks

被引:8
作者
Romanos, Georgios E. [1 ,2 ]
Bastardi, Daniel J. [1 ]
Kakar, Apoory [1 ]
Moore, Rachel [1 ]
Delgado-Ruiz, Rafael A. [3 ]
Javed, Fawad [1 ,4 ]
机构
[1] SUNY Stony Brook, Sch Dent Med, Dept Periodontol, Lab Periodontal Implant Phototherapy LA PIP, Stony Brook, NY 11794 USA
[2] Goethe Univ Frankfurt, Dent Sch, Dept Oral Surg & Implant Dent, Frankfurt, Germany
[3] SUNY Stony Brook, Sch Dent Med, Dept Prosthodont & Digital Technol, Stony Brook, NY 11794 USA
[4] Univ Rochester, Dept Orthodont, Eastman Inst Oral Hlth, Rochester, NY USA
关键词
bone density; implant stability; in vitro; osteotomy; DENTAL IMPLANTS; SURFACE-MORPHOLOGY; OSSEOINTEGRATION; TORQUE;
D O I
10.1111/cid.12842
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background There are no studies that have assessed the implant stability quotient (ISQ) values of narrow diameter implants placed in artificial dense bone blocks at varying drilling speeds (DSs). Purpose The aim of the present in vitro experiment was to compare the performance of OSSTELL and Penguin devices to evaluate implant stability at DSs of 800 and 2000 rpm. Materials and Methods A total of 360 osteotomies were created in dense artificial bone blocks at DSs of 800 and 2000 rpm. Dental implants from three manufacturers (group-1: NobelActive implants, Nobel Biocare, Yorba Linda, California; group-2: Zimmer, Eztetic-Zimmer implants, Zimmer Biomet Dental, Palm Beach Gardens, Florida; and group-3: Astra Tech implant system, Dentsply Sirona, York, Pennsylvania) were randomly placed in these osteotomies using an insertion torque of 15 Ncm (60 implants/group). Implant stability in all bone blocks immediately following implant placement was evaluated using the OSSTELL and Penguin devices. ISQ values were presented as means +/- SD. Statistical significance was set at P < .05. Results There was no significant difference in the ISQ values obtained from the OSSTELL and Penguin devices for implants in groups 1, 2, and 3. There was no significant difference when ISQ values obtained from the OSSTELL device were compared with the Penguin device for narrow diameter dental implants placed in dense bone blocks with osteotomies performed at 800 and 2000 rpm. ISQ values showed statistically significant higher values for OSSTELL compared to Penguin device. Conclusion The OSSTELL and Penguin devices are reliable for the assessment of implant stability in dense artificial bone. Implant design and site-DS does not seem to have a significant impact of implant stability in artificial dense bone blocks.
引用
收藏
页码:1023 / 1027
页数:5
相关论文
共 25 条
[1]   A bisphosphonate-coating improves the fixation of metal implants in human bone. A randomized trial of dental implants [J].
Abtahi, Jahan ;
Tengvall, Pentti ;
Aspenberg, Per .
BONE, 2012, 50 (05) :1148-1151
[2]   Influence of Drilling Speed on Stability of Tapered Dental Implants: An Ex Vivo Experimental Study [J].
Almeida, Karen P. ;
Delgado-Ruiz, Rafael ;
Carneiro, Leandro G. ;
Leiva, Alberto Bordonaba ;
Luis Calvo-Guirado, Jose ;
Gomez-Moreno, Gerardo ;
Malmstrom, Hans ;
Romanos, Georgios E. .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) :795-798
[3]  
Cehreli MC, 2009, INT J ORAL MAX IMPL, V24, P1015
[4]   Effect of internal hexagonal index on removal torque and tensile removal force of different Morse taper connection abutments [J].
de Oliveira Silva, Thalisson Saymo ;
Mendes Alencar, Suya Moura ;
Valente, Valdimar da Silva ;
Vilarinho Soares de Moura, Carmem Dolores .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (05) :621-627
[5]  
Degidi M, 2010, INT J ORAL MAX IMPL, V25, P558
[6]   The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs [J].
Di Stefano, Danilo Alessio ;
Perrotti, Vittoria ;
Greco, Gian Battista ;
Cappucci, Claudia ;
Arosio, Paolo ;
Piattelli, Adriano ;
Iezzi, Giovanna .
JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (03) :227-235
[7]   Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis [J].
Falco, Antonello ;
Berardini, Marco ;
Trisi, Paolo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) :824-830
[8]  
Gaspar J, 2013, ACTA MEDICA PORT, V26, P231
[9]  
Carvalho ACGD, 2011, INT J ORAL MAX IMPL, V26, P1193
[10]   Role of implant diameter on long-term survival of dental implants placed in posterior maxilla: a systematic review [J].
Javed, Fawad ;
Romanos, Georgios E. .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (01) :1-10