Seconds-resolved pharmacokinetic measurements of the chemotherapeutic irinotecan in situ in the living body

被引:85
作者
Idili, Andrea [1 ,2 ]
Arroyo-Curras, Netzahualcoyotl [3 ]
Ploense, Kyle L. [1 ,2 ,4 ]
Csordas, Andrew T. [1 ,2 ]
Kuwahara, Masayasu [5 ]
Kippin, Tod E. [4 ,6 ,7 ]
Plaxco, Kevin W. [1 ,2 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Ctr Bioengn, Santa Barbara, CA 93106 USA
[3] Johns Hopkins Sch Med, Dept Pharmacol & Mol Sci, Baltimore, MD 21205 USA
[4] Univ Calif Santa Barbara, Dept Psychol & Brain Sci, Santa Barbara, CA 93106 USA
[5] Nihon Univ, Grad Sch Integrated Basic Sci, Setagaya Ku, 3-25-40 Sakurajosui, Tokyo 1568550, Japan
[6] Univ Calif Santa Barbara, Dept Mol Cellular & Dev Biol, Santa Barbara, CA 93106 USA
[7] Univ Calif Santa Barbara, Res Inst, Dept Neurosci, Santa Barbara, CA 93106 USA
基金
美国国家卫生研究院;
关键词
CLINICAL PHARMACOKINETICS; CPT-11; DRUG; METABOLISM; EFFICACY; BINDING; PLASMA;
D O I
10.1039/c9sc01495k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The ability to measure drugs in the body rapidly and in real time would advance both our understanding of pharmacokinetics and our ability to optimally dose and deliver pharmacological therapies. To this end, we are developing electrochemical aptamer-based (E-AB) sensors, a seconds-resolved platform technology that, as critical for performing measurements in vivo, is reagentless, reversible, and selective enough to work when placed directly in bodily fluids. Here we describe the development of an E-AB sensor against irinotecan, a member of the camptothecin family of cancer chemotherapeutics, and its adaptation to in vivo sensing. To achieve this we first re-engineered (via truncation) a previously reported DNA aptamer against the camptothecins to support high-gain E-AB signaling. We then co-deposited the modified aptamer with an unstructured, redox-reporter-modified DNA sequence whose output was independent of target concentration, rendering the sensor's signal gain a sufficiently strong function of square-wave frequency to support kinetic-differential-measurement drift correction. The resultant, 200 mu m-diameter, 3 mm-long sensor achieves 20 s-resolved, multi-hour measurements of plasma irinotecan when emplaced in the jugular veins of live rats, thus providing an unprecedentedly high-precision view into the pharmacokinetics of this class of chemotherapeutics.
引用
收藏
页码:8164 / 8170
页数:7
相关论文
共 37 条
[31]  
Takimoto C. H., 2002, ENCY CANC, V1
[32]   Personalized Drug Dosage - Closing the Loop [J].
Tucker, Geoffrey T. .
PHARMACEUTICAL RESEARCH, 2017, 34 (08) :1539-1543
[33]   Pharmacokinetic variability of anticancer agents [J].
Undevia, SD ;
Gomez-Abuin, G ;
Ratain, MJ .
NATURE REVIEWS CANCER, 2005, 5 (06) :447-458
[34]   Cancer Therapies Utilizing the Camptothecins: A Review of the in Vivo Literature [J].
Venditto, Vincent J. ;
Simanek, Eric E. .
MOLECULAR PHARMACEUTICS, 2010, 7 (02) :307-349
[35]   Entropic and Electrostatic Effects on the Folding Free Energy of a Surface-Attached Biomolecule: An Experimental and Theoretical Study [J].
Watkins, Herschel M. ;
Vallee-Belisle, Alexis ;
Ricci, Francesco ;
Makarov, Dmitrii E. ;
Plaxco, Kevin W. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (04) :2120-2126
[36]   Re-engineering aptamers to support reagentless, self-reporting electrochemical sensors [J].
White, Ryan J. ;
Rowe, Aaron A. ;
Plaxco, Kevin W. .
ANALYST, 2010, 135 (03) :589-594
[37]   NUPACK: Analysis and Design of Nucleic Acid Systems [J].
Zadeh, Joseph N. ;
Steenberg, Conrad D. ;
Bois, Justin S. ;
Wolfe, Brian R. ;
Pierce, Marshall B. ;
Khan, Asif R. ;
Dirks, Robert M. ;
Pierce, Niles A. .
JOURNAL OF COMPUTATIONAL CHEMISTRY, 2011, 32 (01) :170-173