Influence of Surgeon Experience on the Accuracy of Implant Placement via a Partially Computer-Guided Surgical Protocol

被引:41
作者
Marei, Hesham F. [1 ]
Abdel-Hady, Adel [1 ]
Al-Khalifa, Khalifa [2 ]
Al-Mahalawy, Haytham [1 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Biomed Dent Sci Dept, POB 1982, Dammam 31441, Saudi Arabia
[2] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dent Publ Hlth, Dammam, Saudi Arabia
关键词
computer-guided surgery; implant placement; surgeon experience; surgical guide; MEDICAL-EDUCATION; TEMPLATES; TISSUE;
D O I
10.11607/jomi.7480
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: There is always a tension between allowing novice trainees to place implants independently and the need to achieve accurate functional and esthetic outcomes. The aim of this study was to measure the influence of surgeon experience on the accuracy of implant placement using a teeth-supported surgical guide via a partially guided surgical protocol. Materials and Methods: Twenty partially edentulous patients were randomly allocated to expert and novice surgeon groups. Implant drilling and placement for the two groups were performed through a flapless surgical technique using surgical guides following a partially guided surgical protocol. The study primary independent variable was the surgeon experience, while the outcome variable was the accuracy, which was measured based on the differences in implant angulations preoperatively and postoperatively. Two-way analysis of variance (ANOVA) was applied to find the influence of surgeon experience, implant size, and the interactive effect of surgeon experience and implant size on the angular deviation. Results: A total of 40 implants were inserted in 7 men and 13 women. There was no significant difference (P = .453) in the mesiodistal deviation between the expert and novice groups. In a buccolingual direction, the expert group performed more accurate implant placement (3.7 +/- 3.35) compared with the novice surgeons (8.5 +/- 6.3). Conclusion: The level of surgeon experience affects the accuracy of implant placement using a teeth-supported surgical guide; therefore, the use of computer-guided surgery via a partially guided protocol does not completely compensate for the level of operator experience. However, such surgical guide might be used in a whole task training of novice surgeons, as it can bridge the gap between simulation training in vitro and freehand surgery in a clinical setting.
引用
收藏
页码:1173 / 1179
页数:7
相关论文
共 19 条
[1]  
[Anonymous], AM J ORTHOD DENTOFAC
[2]   Reliability and accuracy of cone-beam computed tomography dental measurements [J].
Baumgaertel, Sebastian ;
Palomo, J. Martin ;
Palomo, Leena ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :19-25
[3]   In Vivo Tooth-Supported Implant Surgical Guides Fabricated With Desktop Stereolithographic Printers: Fully Guided Surgery Is More Accurate Than Partially Guided Surgery [J].
Bencharit, Sompop ;
Staffen, Adam ;
Yeung, Matthew ;
Whitley, Daniel, III ;
Laskin, Daniel M. ;
Deeb, George R. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (07) :1431-1439
[4]   In-vitro assessment of a registration protocol for image guided implant dentistry [J].
Birkfellner, W ;
Solar, P ;
Gahleitner, A ;
Huber, K ;
Kainberger, F ;
Kettenbach, J ;
Homolka, P ;
Diemling, M ;
Watzek, G ;
Bergmann, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) :69-78
[5]   How much does experience in guided implant surgery play a role in accuracy? A randomized controlled pilot study [J].
Cassetta, M. ;
Bellardini, M. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 46 (07) :922-930
[6]   IMPACT OF OPERATOR EXPERIENCE ON THE ACCURACY OF IMPLANT PLACEMENT WITH STEREOLITHOGRAPHIC SURGICAL TEMPLATES: AN IN VITRO STUDY [J].
Cushen, Sarra E. ;
Turkyilmaz, Ilser .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (04) :248-254
[7]   Current state of the art of computer-guided implant surgery [J].
D'haese, Jan ;
Ackhurst, Johan ;
Wismeijer, Daniel ;
De Bruyn, Hugo ;
Tahmaseb, Ali .
PERIODONTOLOGY 2000, 2017, 73 (01) :121-133
[8]   Effect of Surgical Guide Design and Surgeon's Experience on the Accuracy of Implant Placement [J].
Hinckfuss, Simon ;
Conrad, Heather J. ;
Lin, Lianshan ;
Lunos, Scott ;
Seong, Wook-Jin .
JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (04) :311-324
[9]   Phosphorylation of Serine 235 of the Hepatitis C Virus Non-Structural Protein NS5A by Multiple Kinases [J].
Lee, Kuan-Ying ;
Chen, Yi-Hung ;
Hsu, Shih-Chin ;
Yu, Ming-Jiun .
PLOS ONE, 2016, 11 (11)
[10]   Rehabilitation of Full-Mouth Edentulism: Immediate Loading of Implants Inserted With Computer-Guided Flapless Surgery Versus Conventional Dentures: A 5-Year Multicenter Retrospective Analysis and OHIP Questionnaire [J].
Marra, Roberto ;
Acocella, Alessandro ;
Alessandra, Rispoli ;
Ganz, Scott D. ;
Blasi, Andrea .
IMPLANT DENTISTRY, 2017, 26 (01) :54-58