Safety and efficacy of Coronary Sinus Reducer implantation at 2-year follow-up

被引:15
|
作者
Ponticelli, Francesco [1 ]
Tzanis, Giorgos [1 ]
Gallone, Guglielmo [2 ]
Baldetti, Luca [1 ]
Mangieri, Antonio [3 ]
Colombo, Antonio [3 ,4 ]
Giannini, Francesco [3 ]
机构
[1] IRCCS San Raffaele Sci Inst, Unit Cardiovasc Intervent, Milan, Italy
[2] Univ Turin, Dept Cardiol, Turin, Italy
[3] GVM Care & Res Maria Cecilia Hosp, Intervent Cardiol Unit, Via Madonna di Genova 1, I-48033 Cotignola, RA, Italy
[4] EMO GVM Ctr Cuore Columbus, Milan, Italy
关键词
Chronic refractory angina; Coronary Sinus Reducer; Optimal medical therapy; CHRONIC REFRACTORY ANGINA; DEVICE; PECTORIS; NARROW;
D O I
10.1016/j.ijcard.2019.05.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Coronary Sinus Reducer emerged as promising therapeutic option for patients with refractory angina. While recent literature reports short-term benefits of Reducer implantation, there is paucity of evidence regarding its safety and efficacy at longer follow-up. Methods: In the original cohort of 50 refractory angina patients treated with Reducer at San Raffaele Hospital (Milan, Italy) between March 2015 and August 2016, we reassessed angina symptoms, quality of life and recorded adverse events at 2-year (mean +/- SD: 748 +/- 84 days) follow-up. Results: Canadian Cardiovascular Society (CCS) score improved of >= 1 class in 34 patients (75.6%), and of >= 2 classes in 16 patients (35.6%), translating into a significant mean CCS score reduction at 2-year follow-up (1.74 +/- 0.86 vs. 2.98 +/- 0.52; p < 0.001). Four out of five Seattle Angina Questionnaire items improved significantly (p < 0.001 for all). Ten patients (22%) underwent percutaneous coronary intervention (PCI) during follow-up, three for acute coronary syndromes. Five patients died, two for cardiovascular causes (stroke and cardiac arrest). Conclusions: Safety and efficacy observed in the short follow-up period after Reducer implantation are maintained at two years. Ten patients underwent PCI during follow-up, underlining that Reducer does not affect coronary artery disease progression. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 90
页数:4
相关论文
共 50 条
  • [1] Permanent left atrial pacing: A 2-year follow-up of coronary sinus leads
    Mirza, I
    James, S
    Holt, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (03): : 314 - 317
  • [3] SINUS NODE DYSFUNCTION TREATED OR NOT BY PACEMAKER - 2-YEAR FOLLOW-UP
    MEDVEDOWSKY, JL
    BARNAY, C
    MEDVEDOWSKY, A
    COSTE, A
    JOUVEN, JC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A49 - A49
  • [4] Efficacy of everolimus-eluting stent implantation in patients with small coronary arteries: outcomes of 2-year clinical follow-up
    Yano, H.
    Horinaka, S.
    Ishikawa, M.
    Ishimitsu, T.
    EUROPEAN HEART JOURNAL, 2013, 34 : 864 - 864
  • [5] Efficacy and safety of intravitreal bevacizumab in eyes with neovascular glaucoma undergoing ahmed glaucoma valve implantation: 2-year follow-up
    Arcieri, Enyr S.
    Paula, Jayter S.
    Jorge, Rodrigo
    Barella, Kleyton A.
    Arcieri, Rafael S.
    Secches, Danilo J.
    Costa, Vital P.
    ACTA OPHTHALMOLOGICA, 2015, 93 (01) : E1 - E6
  • [6] Efficacy and safety of intravitreal bevacizumab in eyes with neovascular glaucoma undergoing ahmed glaucoma valve implantation: 2-year follow-up
    Zhou, Minwen
    Wang, Jiawei
    Sun, Xiaodong
    ACTA OPHTHALMOLOGICA, 2016, 94 (01) : E78 - E78
  • [7] Percutaneous Pulmonary Valve Implantation in the Young 2-Year Follow-Up
    Vezmar, Marko
    Chaturvedi, Rajiv
    Lee, Kyong-Jin
    Almeida, Claudia
    Manlhiot, Cedric
    McCrindle, Brian W.
    Horlick, Eric M.
    Benson, Lee N.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) : 439 - 448
  • [8] Efficacy and safety of collagenase treatment for Dupuytren's disease: 2-year follow-up results
    Van Beeck, A.
    Van den Broek, M.
    Michielsen, M.
    Didden, K.
    Vuylsteke, K.
    Verstreken, F.
    HAND SURGERY & REHABILITATION, 2017, 36 (05): : 346 - 349
  • [9] Safety and efficacy of micropulse transscleral cyclophotocoagulation: 2-year follow-up in a tertiary Canadian centre
    Khan, Haaris M.
    Law, Geoffrey
    Docherty, Gavin
    Gooi, Patrick
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2024, 59 (01): : 19 - 23
  • [10] Efficacy of everolimus-eluting stent implantation in patients with small coronary arteries. Outcomes of 2-year clinical follow-up
    Yano, H. Y.
    Ishikawa, M. I.
    Horinaka, S. H.
    Ishimitsu, T. I.
    EUROPEAN HEART JOURNAL, 2014, 35 : 320 - 320