Parity of the band head at 3710 keV in 99Rh using clover detector as Compton polarimeter

被引:73
作者
Palit, R
Jain, HC
Joshi, PK
Nagaraj, S
Rao, BVT
Chintalapudi, SN
Ghugre, SS
机构
[1] Tata Inst Fundamental Res, Bombay 400005, Maharashtra, India
[2] Andhra Univ, Waltair 530003, Andhra Pradesh, India
[3] Interuniv Consortium DAE Facil, Calcutta 700091, W Bengal, India
来源
PRAMANA-JOURNAL OF PHYSICS | 2000年 / 54卷 / 03期
关键词
linear polarization; clover detector; multipolarity; polarization sensitivity; Compton process;
D O I
10.1007/s12043-000-0126-x
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Clover detector has been used as a Compton polarimeter to measure the linear polarization of gamma-rays produced in heavy ion fusion reaction. The polarization sensitivity of the clover detector has been measured over gamma-ray energies ranging from 386 to 1368 keV. The E1 multipolarity of the 1117 keV transition in Rh-99 has been established using this polarimeter. This has resulted in the assignment of negative parity to the band head at 3710 keV in Rh-99.
引用
收藏
页码:347 / 354
页数:8
相关论文
共 13 条
[1]   3 GE(LI) COMPTON POLARIMETER FOR NUCLEAR-REACTION GAMMA-RAYS [J].
ASHIBE, K ;
ADACHI, M ;
TAKETANI, H .
NUCLEAR INSTRUMENTS & METHODS, 1975, 130 (01) :221-225
[2]   TEST AND APPLICATION OF A SYMMETRICAL 4-DETECTOR COMPTON POLARIMETER FOR LOW-TEMPERATURE NUCLEAR ORIENTATION AND IN-BEAM SPECTROSCOPY [J].
DENG, JK ;
MA, WC ;
HAMILTON, JH ;
RAMAYYA, AV ;
RIKOVSKA, J ;
STONE, NJ ;
CROFT, WL ;
PIERCEY, RB ;
MORGAN, JC ;
MANTICA, PF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (1-2) :242-250
[3]   POLARIZATION MEASUREMENTS ON NUCLEAR GAMMA-RAYS [J].
FAGG, LW ;
HANNA, SS .
REVIEWS OF MODERN PHYSICS, 1959, 31 (03) :711-758
[4]   SPECTROSCOPY OF RU-95 AT HIGH SPINS [J].
GHUGRE, SS ;
PATEL, SB ;
GUPTA, M ;
BHOWMIK, RK ;
SHEIKH, JA .
PHYSICAL REVIEW C, 1994, 50 (03) :1346-1354
[5]   ALIGNMENTS AND BAND TERMINATION IN RU-99,RU-100 [J].
GIZON, J ;
JERRESTAM, D ;
GIZON, A ;
JOZSA, M ;
BARK, R ;
FOGELBERG, B ;
IDEGUCHI, E ;
KLAMRA, W ;
LINDBLAD, T ;
MITARAI, S ;
NYBERG, J ;
PIIPARINEN, M ;
SLETTEN, G .
ZEITSCHRIFT FUR PHYSIK A-HADRONS AND NUCLEI, 1993, 345 (03) :335-336
[6]   Study of the characteristics of a clover detector [J].
Joshi, PK ;
Jain, HC ;
Medhi, AS ;
Chattopadhyay, S ;
Bhattacharya, S ;
Goswami, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (01) :51-56
[7]   HIGH-SPIN STATES IN RH-99 [J].
KUMAR, VR ;
LAKSHMINARAYANA, V ;
RAO, BVT ;
RAJU, MLN ;
REDDY, TS ;
LAKSHMINARAYANA, S ;
NARASIMHAM, KL ;
PREMACHAND, K ;
RAO, BM ;
BHOWMIK, RK .
JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 1994, 20 (03) :441-450
[8]  
MORINAGA H, 1976, IN BEAM GAMMA RAY SP, P15
[9]   SPECTROSCOPY OF RU-96, RU-97, RU-98 - POSSIBLE EMERGENCE OF COLLECTIVITY AT N-GREATER-THAN-OR-EQUAL-TO-52 [J].
REVIOL, W ;
GARG, U ;
AHMAD, I ;
APRAHAMIAN, A ;
CARPENTER, MP ;
DAVIS, BF ;
JANSSENS, RVF ;
KHOO, TL ;
LAURITSEN, T ;
LIANG, Y ;
NAGULESWARAN, S ;
WALPE, JC ;
YE, D .
NUCLEAR PHYSICS A, 1993, 557 :C391-C400
[10]   APPLICATION OF A SECTORED GE(LI) DETECTOR AS A COMPTON POLARIMETER [J].
SIMPSON, J ;
BUTLER, PA ;
EKSTROM, LP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 204 (2-3) :463-469