Preliminary investigations of two types of silica-based dosimeter for small-field radiotherapy

被引:5
作者
Alalawi, Amani I. [1 ,2 ]
Jafari, S. M. [1 ,3 ]
Najem, M. A. [1 ]
Alsaleh, W. [4 ,5 ,6 ]
Clark, C. H. [7 ,8 ]
Nisbet, A. [1 ,8 ]
Abolaban, F. [9 ]
Hugtenburg, R. P. [4 ,5 ]
Hussein, M. [1 ,8 ]
Alzimami, Khalid S. [1 ,10 ]
Bradley, D. A. [1 ,11 ]
Spyrou, N. M. [1 ]
机构
[1] Univ Surrey, Dept Phys, Ctr Nucl & Radiat Phys, Guildford GU2 7XH, Surrey, England
[2] Umm Al Qura Univ, Fac Sci Appl, Dept Phys, Mecca, Saudi Arabia
[3] Kabul Med Univ, Dept Radiol, Fac Med, Kabul, Afghanistan
[4] Swansea Univ, Abertawe Bro Morgannwg UHB, Dept Med Phys & Clin Engn, Swansea SA2 8PP, W Glam, Wales
[5] Swansea Univ, Sch Med, Swansea SA2 8PP, W Glam, Wales
[6] King Saud Bin Abdulaziz Univ Hlth Sci, Al Hufuf, Saudi Arabia
[7] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[8] Royal Surrey Cty Hosp NHS Trust, Dept Med Phys, Guildford GU2 7XX, Surrey, England
[9] King Abdulaziz Univ, Fac Engn, Nucl Dept, Jeddah 21589, Saudi Arabia
[10] King Saud Univ, Dept Radiol Sci, Riyadh 11432, Saudi Arabia
[11] Univ Malaya, Dept Phys, Kuala Lumpur 50603, Malaysia
关键词
Small field dosimetry; Thermoluminescent dosimeter; Monte Carlo simulation; X-RAY-BEAMS; OUTPUT FACTOR MEASUREMENT; ENERGY PHOTON BEAMS; GLASS ROD DETECTOR; HEAD-SCATTER; MONTE-CARLO; GAMMA-KNIFE; CYBERKNIFE; RADIATION; FILM;
D O I
10.1016/j.radphyschem.2014.05.004
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Two thermoluminescent dosimeters (SiO2-GeO2 doped fibres and glass beads (GB)) were used to measure small photon field doses and compared against GAFCHROMIC film, a small ionisation chamber (RK-018) and a p-type silicon diode (SCANDITRONIX, F1356), as well as Monte Carlo simulations with FLUKA and BEAMnrc/DOSXYZnrc. Ge-doped SiO2 fibres have been shown by this group to offer a viable system for use as dosimeters. The fibres and GB offer good spatial resolution (similar to 120 mu m and 2 mm respectively), large dynamic dose range (with linearity from tens of mGy up to well in excess of many tens of Gy), are nonhygroscopic and are of low cost. Measurements of beam profiles for field sizes of 10 mm x 10 mm, 20 mm x 20 mm, 30 mm x 30 mm, 40 mm x 40 mm, and 100 mm x 100 mm were carried out. Through the use of a customised solid water phantom, doped optical fibres and GBs were placed at defined positions along the x-and y-axes to allow accurate beam profile measurement. The maximum difference between FWHM measurements was 1.8 mm. For penumbra measurements (measured between 80% and 20% isodoses), the maximum difference was <1 mm. These measurements indicate good agreement, within measurement uncertainty, with Gafchromic film, data obtained from the use of two commonly used detectors and FLUKA and BEAMnrc/ DOSXYZnrc simulations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 37 条
[1]   Application of a radiophotoluminescent glass plate dosimeter for small field dosimetry [J].
Aaki, F ;
Ishidoya, T ;
Ikegami, T ;
Moribe, N ;
Yamashita, Y .
MEDICAL PHYSICS, 2005, 32 (06) :1548-1554
[2]   A new formalism for reference dosimetry of small and nonstandard fields [J].
Alfonso, R. ;
Andreo, P. ;
Capote, R. ;
Huq, M. Saiful ;
Kilby, W. ;
Kjaell, P. ;
Mackie, T. R. ;
Palmans, H. ;
Rosser, K. ;
Seuntjens, J. ;
Ullrich, W. ;
Vatnitsky, S. .
MEDICAL PHYSICS, 2008, 35 (11) :5179-5186
[3]  
[Anonymous], 2007, HDB RADIOTHERAPY PHY, DOI DOI 10.1201/9781420012026
[4]   Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and Cyber-Knife [J].
Araki, F ;
Moribe, N ;
Shimonobou, T ;
Yamashita, Y .
MEDICAL PHYSICS, 2004, 31 (07) :1980-1986
[5]   Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector [J].
Araki, F ;
Ikegami, T ;
Ishidoya, T ;
Kubo, HD .
MEDICAL PHYSICS, 2003, 30 (08) :1976-1981
[6]  
Aspradakis M., 2010, SMALL FIELD MV PHOTO
[7]  
Attix F H, 1986, INTRO RADIOLOGICAL P
[8]   Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones [J].
Bassinet, C. ;
Huet, C. ;
Derreumaux, S. ;
Brunet, G. ;
Chea, M. ;
Baumann, M. ;
Lacornerie, T. ;
Gaudaire-Josset, S. ;
Trompier, F. ;
Roch, P. ;
Boisserie, G. ;
Clairand, I. .
MEDICAL PHYSICS, 2013, 40 (07)
[9]  
Battistoni G, 2007, AIP CONF PROC, V896, P31, DOI 10.1063/1.2720455
[10]  
BJARNGARD BE, 1990, MED PHYS, V17, P794, DOI 10.1118/1.596475