Evaluation of a novel high-resolution mapping system for catheter ablation of ventricular arrhythmias

被引:47
作者
Viswanathan, Karthik [1 ]
Mantziari, Lilian [1 ]
Butcher, Charles [1 ]
Hodkinson, Emily [1 ]
Lim, Eric [1 ]
Khan, Habib [1 ]
Panikker, Sandeep [1 ]
Haldar, Shouvik [1 ]
Jarman, Julian W. E. [1 ]
Jones, David G. [1 ]
Hussain, Wajid [1 ]
Foran, John P. [1 ]
Markides, Vias [1 ]
Wong, Tom [1 ]
机构
[1] Imperial Coll, Royal Brompton & Harefield NHS Fdn Trust, NIHR Cardiovasc Biomed Res Unit, London, England
关键词
Ventricular tachycardia; High-resolution mapping; High-density mapping; Catheter ablation; Minibasket catheter; Automatic mapping system; TACHYCARDIA;
D O I
10.1016/j.hrthm.2016.11.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The mapping of ventricular arrhythmias in humans using a minibasket 64-electrode catheter paired with a novel automatic mapping system (Rhythmia) has not been evaluated. OBJECTIVE The purpose of this study was to evaluate the safety and efficacy of mapping ventricular arrhythmias and clinical outcomes after ablation using this system. METHODS Electroanatomic maps for ventricular arrhythmias were obtained during 20 consecutive procedures in 19 patients (12 with ventricular tachycardia [VT] and 2 with ventricular ectopy [VE]). High-density maps were acquired using automatic beat acceptance and automatic system annotation of electrograms. RESULTS Forty-seven electroanatomic maps (including 3 right ventricular and 9 epicardial maps) were obtained. Left ventricular endocardial mapping by transseptal (n = 13) and/or transaortic (n = 11) access was safe with no complications related to the minibasket catheter. VT substrate maps (n = 14; median 10,184 points) consistently demonstrated late potentials with high resolution. VT activation maps (n = 25; median 6401 points) obtained by automatic annotation included 7 complete maps (covering >= 90% of the tachycardia cycle length) in 5 patients in whom the entire VT circuit was accurately visualized. VE timing maps (n = 8) successfully localized the origin of VEs in all, with all accepted beats consistent with clinical VEs. Over a median follow-up of 10 months, no arrhythmia recurrence was noted in 75% after VT ablation and 86% after VE ablation. CONCLUSION In this first human experience for ventricular arrhythmias using this system, ultra-high-density maps were created rapidly and safely, with a reliable automatic annotation of VT and consistent recording of abnormal electrograms. Medium-term outcomes after ablation were encouraging. Further larger studies are needed to validate these findings.
引用
收藏
页码:176 / 183
页数:8
相关论文
共 10 条
  • [1] Evaluation of a novel high-resolution mapping technology for ablation of recurrent scar-related atrial tachycardias
    Anter, Elad
    McElderry, Thomas H.
    Contreras-Valdes, Fernando M.
    Li, Jianqing
    Tung, Patricia
    Leshem, Eran
    Haffajee, Charles I.
    Nakagawa, Hiroshi
    Josephson, Mark E.
    [J]. HEART RHYTHM, 2016, 13 (10) : 2048 - 2055
  • [2] Anter Elad, 2015, HeartRhythm Case Rep, V1, P472
  • [3] High-Resolution Mapping of Postinfarction Reentrant Ventricular Tachycardia Electrophysiological Characterization of the Circuit
    Anter, Elad
    Tschabrunn, Cory M.
    Buxton, Alfred E.
    Josephson, Mark E.
    [J]. CIRCULATION, 2016, 134 (04) : 314 - +
  • [4] Differences in Complication Rates Between Large Bore Needle and a Long Micropuncture Needle During Epicardial Access Time to Change Clinical Practice?
    Gunda, Sampath
    Reddy, Madhu
    Pillarisetti, Jayasree
    Atoui, Moustapha
    Badhwar, Nitish
    Swarup, Vijay
    DiBiase, Luigi
    Mohanty, Sanghamitra
    Mohanty, Prashanth
    Nagaraj, Hosakote
    Ellis, Christopher
    Rasekh, Abdi
    Cheng, Jie
    Bartus, Krzysztof
    Lee, Randall
    Natale, Andrea
    Lakkireddy, Dhanunjaya
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (04) : 890 - 895
  • [5] Josephson Mark E, 2015, JACC Clin Electrophysiol, V1, P341, DOI 10.1016/j.jacep.2015.09.001
  • [6] Mantziari Lilian, 2015, JACC Clin Electrophysiol, V1, P411, DOI 10.1016/j.jacep.2015.06.002
  • [7] Sacher F, 2016, HEART RHYTHM, V13, pS32
  • [8] Ventricular Tachycardia Ablation Evolution of Patients and Procedures Over 8 Years
    Sacher, Frederic
    Tedrow, Usha B.
    Field, Michael E.
    Raymond, Jean-Marc
    Koplan, Bruce A.
    Epstein, Laurence M.
    Stevenson, William G.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2008, 1 (03) : 153 - 161
  • [9] Utility of high-resolution electroanatomic mapping of the left ventricle using a multispline basket catheter in a swine model of chronic myocardial infarction
    Tanaka, Yasuaki
    Genet, Martin
    Lee, Lik Chuan
    Martin, Alastair J.
    Sievers, Richard
    Gerstenfeld, Edward P.
    [J]. HEART RHYTHM, 2015, 12 (01) : 144 - 154
  • [10] Characteristics of Clinical and Induced Ventricular Tachycardia Throughout Multiple Ablation Procedures
    Tokuda, Michifumi
    Kojodjojo, Pipin
    Tung, Stanley
    Inada, Keiichi
    Matsuo, Seiichiro
    Yamane, Teiichi
    Yoshimura, Michihiro
    Tedrow, Usha B.
    Stevenson, William G.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (01) : 88 - 94