Dual-Energy X-Ray Absorptiometry, Skinfold Thickness, and Waist Circumference for Assessing Body Composition in Ambulant and Non-Ambulant Wheelchair Games Players

被引:22
|
作者
Willems, Annika [1 ]
Paulson, Thomas A. W. [1 ]
Keil, Mhairi [2 ]
Brooke-Wavell, Katherine [3 ]
Goosey-Tolfrey, Victoria L. [1 ]
机构
[1] Univ Loughborough, Peter Harrison Ctr Disabil Sport, Sch Sport Exercise & Hlth Sci, Loughborough, Leics, England
[2] Lilleshall Natl Sport Ctr, English Inst Sport, Sheffield, S Yorkshire, England
[3] Univ Loughborough, Sch Sport Exercise & Hlth Sci, Loughborough, Leics, England
来源
FRONTIERS IN PHYSIOLOGY | 2015年 / 6卷
关键词
spinal cord injury; paralympic; total body mass; basketball; rugby; SPINAL-CORD-INJURY; SIMPLE ANTHROPOMETRIC MEASUREMENTS; ABDOMINAL ADIPOSITY; MASS INDEX; FAT; PREDICTION; DENSITY; WOMEN; RISK; TISSUE;
D O I
10.3389/fphys.2015.00356
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Field-based assessments provide a cost effective and accessible alternative to dual-energy X-ray absorptiometry (DXA) for practitioners determining body composition in athletic populations. It remains unclear how the range of physical impairments classifiable in wheelchair sports may affect the utility of field-based body composition techniques. The present study assessed body composition using DXA in 14 wheelchair games players who were either wheelchair dependent (non-walkers; n = 7) or relied on a wheelchair for sports participation only (walkers; n = 7). Anthropometric measurements were used to predict body fat percentage with existing regression equations established for able-bodied persons by Sloan and Weir, Durnin and Womersley, Lean et al, Gallagher et al, and Pongchaiyakul et al. In addition, linear regression analysis was performed to calculate the association between body fat percentage and BMI, waist circumference, sum of 6 skinfold thickness and sum of 8 skinfold thickness. Results showed that non-walkers had significantly lower total lean tissue mass (46.2 +/- 6.6 kg vs. 59.4 +/- 8.2 kg, P = 0.006) and total body mass (65.8 +/- 4.2 kg vs. 79.4 +/- 14.9 kg; P = 0.05) than walkers. Body fat percentage calculated from most existing regression equations was significantly lower than that from DXA, by 2 to 9% in walkers and 8 to 14% in non-walkers. Of the anthropometric measurements, the sum of 8 skinfold thickness had the lowest standard error of estimation in predicting body fat content. In conclusion, existing anthropometric equations developed in able-bodied populations substantially underestimated body fat content in wheelchair athletes, particularly non-walkers. Impairment specific equations may be needed in wheelchair athletes.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] In vivo measurement of human body composition by dual-energy X-ray absorptiometry (DXA)
    Thomsen, TK
    Jensen, VJ
    Henriksen, MG
    EUROPEAN JOURNAL OF SURGERY, 1998, 164 (02) : 133 - 137
  • [22] Assessing body composition in taller or broader individuals using dual-energy X-ray absorptiometry: a systematic review
    Silva, A. M.
    Heymsfield, S. B.
    Sardinha, L. B.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (10) : 1012 - 1021
  • [23] Quantifying Body Segment Parameters Using Dual-Energy X-Ray Absorptiometry: A Paralympic Wheelchair Curler Case Report
    Laschowski, Brock
    McPhee, John
    ENGINEERING OF SPORT 11, 2016, 147 : 163 - 167
  • [24] Waist circumference and dual-energy X-ray absorptiometry measures of overall and central obesity are similarly associated with systemic oxidative stress in women
    Cervellati, Carlo
    Bonaccorsi, Gloria
    Cremonini, Eleonora
    Romani, Arianna
    Castaldini, Cristina
    Ferrazzini, Stefania
    Giganti, Melchiorre
    Fila, Enrica
    Massari, Leo
    Bergamini, Carlo M.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2014, 74 (02) : 102 - 107
  • [25] Comparison of computed tomography and dual-energy X-ray absorptiometry in the evaluation of body composition in patients with obesity
    Palmas, Fiorella
    Ciudin, Andreea
    Guerra, Raul
    Eiroa, Daniel
    Espinet, Carina
    Roson, Nuria
    Burgos, Rosa
    Simo, Rafael
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [26] Assessment of the body composition of patients with polycystic ovary syndrome using dual-energy X-ray absorptiometry
    Macruz, Carolina F.
    Lima, Sonia M. R. R.
    Salles, Joao E. N.
    da Silva, Gustavo M. D.
    Scalissi, Nilza M.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2017, 136 (03) : 285 - 289
  • [27] Body composition assessment in athletes with spinal cord injury: comparison of field methods with dual-energy X-ray absorptiometry
    M C Mojtahedi
    R J Valentine
    E M Evans
    Spinal Cord, 2009, 47 : 698 - 704
  • [28] In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry
    Prior, BM
    Cureton, KJ
    Modlesky, CM
    Evans, EM
    Sloniger, MA
    Saunders, M
    Lewis, RD
    JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (02) : 623 - 630
  • [29] Accuracy and precision of dual-energy X-ray absorptiometry for body composition measurements in rhesus monkeys
    Black, A
    Tilmont, EM
    Baer, DJ
    Rumpler, DK
    Roth, GS
    Lane, MA
    JOURNAL OF MEDICAL PRIMATOLOGY, 2001, 30 (02) : 94 - 99
  • [30] Detecting meaningful body composition changes in athletes using dual-energy x-ray absorptiometry
    Colyer, Steffi L.
    Roberts, Simon P.
    Robinson, Jonathan B.
    Thompson, Dylan
    Stokes, Keith A.
    Bilzon, James L. J.
    Salo, Aki I. T.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (04) : 596 - 609