In-situ Real-Time Monitoring of Volatile Organic Compound Exposure and Heart Rate Variability for Patients with Multiple Chemical Sensitivity

被引:7
作者
Mizukoshi, Atsushi [1 ,2 ]
Kumagai, Kazukiyo [3 ]
Yamamoto, Naomichi [4 ]
Noguchi, Miyuki [5 ]
Yoshiuchi, Kazuhiro [6 ]
Kumano, Hiroaki [2 ,7 ]
Sakabe, Kou [8 ]
Yanagisawa, Yukio [9 ]
机构
[1] Kinki Univ, Dept Environm Med & Behav Sci, Fac Med, Osakasayama, Osaka 5898511, Japan
[2] Waseda Univ, Inst Appl Brain Sci, Tokorozawa, Saitama 3591192, Japan
[3] Calif Dept Publ Hlth, Environm Hlth Lab, Richmond, CA 94804 USA
[4] Seoul Natl Univ, Grad Sch Publ Hlth, Dept Environm Hlth Sci, Seoul 151742, South Korea
[5] Seikei Univ, Fac Sci & Technol, Dept Mat & Life Sci, Musashino, Tokyo 1808633, Japan
[6] Univ Tokyo, Grad Sch Med, Dept Stress Sci & Psychosomat Med, Bunkyo Ku, Tokyo 1138655, Japan
[7] Waseda Univ, Fac Human Sci, Tokorozawa, Saitama 3591192, Japan
[8] Tokai Univ, Dept Anat & Cellular Biol, Sch Med, Isehara, Kanagawa 2591193, Japan
[9] Univ Tokyo, Bunkyo Ku, Tokyo 1138654, Japan
关键词
real-time monitoring; MCS; VOC; HRV; PERSONAL EXPOSURE; INTOLERANCES; DISEASE; SYMPTOM; AIR;
D O I
10.3390/ijerph121012446
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In-situ real-time monitoring of volatile organic compound (VOC) exposure and heart rate variability (HRV) were conducted for eight multiple chemical sensitivity (MCS) patients using a VOC monitor, a Holter monitor, and a time-activity questionnaire for 24 h to identify the relationship between VOC exposure, biological effects, and subjective symptoms in actual life. The results revealed no significantly different parameters for averaged values such as VOC concentration, HF (high frequency), and LF (low frequency) to HF ratio compared with previous data from healthy subjects (Int. J. Environ. Res. Public Health2010, 7, 4127-4138). Significant negative correlations for four subjects were observed between HF and amounts of VOC change. These results suggest that some patients show inhibition of parasympathetic activities along with VOC exposure as observed in healthy subjects. Comparing the parameters during subjective symptoms and normal condition, VOC concentration and/or VOC change were high except for one subject. HF values were low for five subjects during subjective symptoms. Examining the time-series data for VOC exposure and HF of each subject showed that the subjective symptoms, VOC exposure, and HF seemed well related in some symptoms. Based on these characteristics, prevention measures of symptoms for each subject may be proposed.
引用
收藏
页码:12446 / 12465
页数:20
相关论文
共 39 条
[11]   In-situ nanoelectrospray for high-throughput screening of enzymes and real-time monitoring of reactions [J].
Yang, Yuhan ;
Han, Feifei ;
Ouyang, Jin ;
Zhao, Yunling ;
Han, Juan ;
Na, Na .
ANALYTICA CHIMICA ACTA, 2016, 902 :135-141
[12]   Embedded real-time and in-situ fatigue life monitoring sensor with load types identification [J].
Gao, Qiang ;
Yang, Bowen ;
Huo, Junzhou ;
Han, Jialin .
SENSORS AND ACTUATORS A-PHYSICAL, 2022, 347
[13]   Real-Time Monitoring of Volatile Organic Compound-Mediated Plant Intercommunication Using Surface-Enhanced Raman Scattering Nanosensor [J].
Choi, Yun Sik ;
Son, Won Ki ;
Kwak, Hyuna ;
Park, Jiyeun ;
Choi, Sumin ;
Sim, Daeseob ;
Kim, Min Gyeong ;
Kimm, Hyungsuk ;
Son, Hokyoung ;
Jeong, Dae Hong ;
Kwak, Seon-Yeong .
ADVANCED SCIENCE, 2025, 12 (07)
[14]   Concentration Characteristics of Particulate Matter and Volatile Organic Compounds in Petrochemical Industrial Complex using Real-time Monitoring Devices [J].
Kim, Jong Bum ;
Park, Duckshin ;
Park, Sechan ;
Micheal, Versoza ;
Lee, Yongil ;
Lee, Sang Sin ;
Park, Jong-Sung ;
Kim, Jeongho .
JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2019, 35 (06) :683-700
[15]   In-situ autocalibrated electrospinning process via U-Net based real-time monitoring [J].
Kim, Yeong-Seo ;
Hyun, Goan-Woo ;
Park, Suk-Hee .
JOURNAL OF MANUFACTURING PROCESSES, 2025, 137 :397-407
[16]   A real-time and in-situ monitoring of the molecular interactions between drug carrier polymers and a phospholipid membrane [J].
Ge, Yuke ;
Liu, Jiaojiao ;
Dou, Yujiang ;
Chen, Zhonglan ;
Li, Zihan ;
Yang, Kai ;
Yuan, Bing ;
Kang, Zhenhui .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2022, 209
[17]   Development and in-situ application of a real-time monitoring system for the interaction between TBM and surrounding rock [J].
Huang, Xing ;
Liu, Quangsheng ;
Liu, He ;
Zhang, Penglin ;
Pan, Shaolin ;
Zhang, Xiaoping ;
Fang, Jingnian .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 81 :187-208
[18]   Real-time Monitoring of Heart Rate using Wellness Belt Equipped with Electrocardiogram Sensors [J].
Meng Yao .
PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, :4999-5002
[19]   A Flexible Wireless Sensor Patch for Real-Time Monitoring of Heart Rate and Body Temperature [J].
Yun, Seok-Oh ;
Lee, Jung Hoon ;
Lee, Jin ;
Kim, Choul-Young .
IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2019, E102D (05) :1115-1118
[20]   An IoT Wi-Fi Connected Sensor For Real Time Heart Rate Variability Monitoring [J].
Rajanna, Rama Reddy ;
Natarajan, Sriraam ;
Vittal, Prabhu Ravikala .
2018 3RD INTERNATIONAL CONFERENCE ON CIRCUITS, CONTROL, COMMUNICATION AND COMPUTING (I4C), 2018,