A NEW REVERSE PHASE HPLC METHOD WITH FLUORESCENT DETECTION FOR THE DETERMINATION OF SALBUTAMOL SULFATE IN HUMAN PLASMA

被引:0
作者
Murtaza, Ghulam [1 ]
Ahmad, Mahmood [1 ]
Madni, Muhammad Asadullah [1 ]
Asghar, Muhammad Waheed [1 ]
机构
[1] Islamia Univ Bahawalpur, Fac Pharm & Alternat Med, Dept Pharmaceut, Bahawalpur 63100, Pakistan
关键词
Salbutamol sulfate; RP-HPLC method; Fluorescent detection; Ion-pair extraction; Human plasma; PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN URINE; ALBUTEROL; CLEANUP;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A sensitive reverse phase-high performance liquid chromatography (RP-HPLC) method with fluorescent detector (FLD) was developed and optimized for salbutamol sulfate (SS) determination in human plasma. In this regard, mobile phase specifications, extraction procedures and excitation and emission wavelengths were optimized. The HPLC system consisted of a Lichrosorb RP-C18 analytical column (4.6 x 200 mm, 5 mu m) with FLD operated at excitation 228 nm and emission 310 nm. Mobile phase {CH3OH/(NH4)H2PO4 (67 mM) (pH 3.0)/triethylamine (TEA), 50/50/0.02 (v/v/v %)} was run at a flow rate of 0.7 mL/min. To clean up the samples, a liquid-liquid extraction (LLE) procedure was selected and optimized. SS and tramadol hydrochloride (TH) eluted at 4.1 min and 5.2 min, respectively. Adequate extraction efficiency was achieved by DEHP (75.88-85.52 %). The standard curve was linear for the range tested (0.5-80 ng/mL) and the coefficient of determination was 0.9989. A detection limit of 0.17 ng/mL was achieved. The intra- and inter-day precision was less than 4 %. The present assay combines adequate accuracy and precision with sensitivity for SS determination in human plasma and can be applied to study pharmacokinetics of SS sustained release tablets after oral administration in human.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 14 条
[1]  
CARUSO JF, 1995, MED SCI SPORT EXER, V27, P1471
[2]  
DOLLEY C, 1991, THERAPEUTIC DRUG, V2, P51
[3]   Quantification and stability of salbutamol in human urine [J].
Forsdahl, G ;
Gmeiner, G .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (1-2) :110-114
[4]   DETERMINATION OF SALBUTAMOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
HUTCHINGS, MJ ;
PAULL, JD ;
MORGAN, DJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 277 (OCT) :423-426
[5]   A simple method for the study of salbutamol pharmacokinetics by ion chromatography with direct conductivity detection [J].
Jin, OY ;
Duan, JL ;
Baeyens, WRG ;
Delanghe, JR .
TALANTA, 2005, 65 (01) :1-6
[6]   SALBUTAMOL, A BETA-2-ADRENOCEPTOR AGONIST, INCREASES SKELETAL-MUSCLE STRENGTH IN YOUNG MEN [J].
MARTINEAU, L ;
HORAN, MA ;
ROTHWELL, NJ ;
LITTLE, RA .
CLINICAL SCIENCE, 1992, 83 (05) :615-621
[7]   ANALYSIS OF ALBUTEROL IN HUMAN-PLASMA BASED ON IMMUNOAFFINITY CHROMATOGRAPHIC CLEANUP COMBINED WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORIMETRIC DETECTION [J].
ONG, H ;
ADAM, A ;
PERREAULT, S ;
MARLEAU, S ;
BELLEMARE, M ;
DUSOUICH, P ;
BEAULIEU, N .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 :213-221
[8]  
Qin Yongping, 2003, Sichuan Da Xue Xue Bao Yi Xue Ban, V34, P576
[9]   ANALYSIS OF SALBUTAMOL IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A MICRO-ELECTROCHEMICAL FLOW CELL [J].
SAGAR, KA ;
HUA, C ;
KELLY, MT ;
SMYTH, MR .
ELECTROANALYSIS, 1992, 4 (04) :481-486
[10]   Clean-up, detection and determination of salbutamol in human urine and serum [J].
Saleh, MI ;
Koh, YM ;
Tan, SC ;
Aishah, AL .
ANALYST, 2000, 125 (09) :1569-1572