Contained aortic annulus rupture with persisting false aneurysm after transfemoral transcatheter aortic valve implantation

被引:7
|
作者
Egenrieder, Stephanie [1 ]
Hill, Stephan [1 ]
Backes, Maik [2 ]
Voehringer, Matthias [3 ]
Sechtem, Udo [1 ]
机构
[1] Robert Bosch Krankenhaus, Abt Kardiol, D-70376 Stuttgart, Germany
[2] Robert Bosch Krankenhaus, Inst Radiol, D-70376 Stuttgart, Germany
[3] CCLB Ludwigsburg, Ludwigsburg, Germany
关键词
Transfemoral transcatheter aortic valve implantation; Aortic annulus rupture; False aneurysm; ROOT;
D O I
10.1007/s00392-014-0696-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
With older age and increasing comorbidities, conventional operative procedures for severe symptomatic aortic stenosis are associated with a high surgical risk. To date, transfemoral transcatheter aortic valve implantation (TF-TAVI) represents an accepted alternative method of intervention with a cardiovascular and all-cause mortality similar to operative replacement at early and long-term follow-up in this high risk population (Thomas et al., Circulation 124:425-433, 2011). Despite growing experience of the operators and improvement of the devices procedural and perioperative complications still occur (Panchal et al., Am J Cardiol, 2013). Aortic annulus rupture as well as the rupture of the membranous ventricular septum has been reported (Aminian et al., Catheter Cardiovasc Interv 81:E72-E75, 2013). We present the unusual case of an 80-year-old female who developed a false aneurysm following a contained aortic annulus rupture during a TF-TAVI procedure.
引用
收藏
页码:599 / 601
页数:3
相关论文
共 50 条
  • [21] Transesophageal echocardiography measurements of aortic annulus diameter using biplane mode in patients undergoing transcatheter aortic valve implantation
    Shahgaldi, Kambiz
    da Silva, Cristina
    Back, Magnus
    Ruck, Andreas
    Manouras, Aristomenis
    Sahlen, Anders
    CARDIOVASCULAR ULTRASOUND, 2013, 11
  • [22] Manual versus automatic detection of aortic annulus plane in a computed tomography scan for transcatheter aortic valve implantation screeningaEuro
    Van Linden, Arnaud
    Kempfert, Joerg
    Blumenstein, Johannes
    Moellmann, Helge
    Kim, Won-Keun
    Alkaya, Serap
    Hamm, Christian
    Walther, Thomas
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 46 (02) : 207 - 212
  • [23] Transcatheter valve implantation for patients with aortic stenosis
    Vahanian, Alec
    Himbert, Dominique
    Brochet, Eric
    HEART, 2010, 96 (22) : 1849 - 1856
  • [24] An In Vitro Model of Aortic Stenosis for the Assessment of Transcatheter Aortic Valve Implantation
    Maleki, Hoda
    Shahriari, Shahrokh
    Labrosse, Michel
    Pibarot, Philippe
    Kadem, Lyes
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (05):
  • [25] Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis
    Miyashita, Hirokazu
    Moriyama, Noriaki
    Yamanaka, Futoshi
    Saito, Shigeru
    Lehtola, Heidi
    Piuhola, Jarkko
    Niemela, Matti
    Laine, Mika
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (07) : 1576 - 1586
  • [26] Prediction of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation by Computed Tomography: Value of Aortic Valve and Annular Calcification
    Feuchtner, Gudrun
    Plank, Fabian
    Bartel, Thomas
    Mueller, Silvana
    Leipsic, Jonathon
    Schachner, Thomas
    Mueller, Ludwig
    Friedrich, Guy
    Klauser, Andrea
    Grimm, Michael
    Bonaros, Nikolaos
    ANNALS OF THORACIC SURGERY, 2013, 96 (05): : 1574 - 1580
  • [27] Comparison of Aortic Annulus Dimension After Aortic Valve Neocuspidization With Valve Replacement and Normal Valve
    Yamamoto, Yoshitaka
    Iino, Kenji
    Shintani, Yoshiko
    Kato, Hiroki
    Kimura, Keiichi
    Watanabe, Go
    Takemura, Hirofumi
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2017, 29 (02) : 143 - 149
  • [28] Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Leipsic, Jonathon
    Gurvitch, Ronen
    LaBounty, Troy M.
    Min, James K.
    Wood, David
    Johnson, Mark
    Ajlan, Amr M.
    Wijesinghe, Namal
    Webb, John G.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 416 - 429
  • [29] Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement
    Buellesfeld, Lutz
    Stortecky, Stefan
    Beg, Dik
    Gloekler, Steffen
    Meier, Bernhard
    Wenaweser, Peter
    Windecker, Stephan
    EUROINTERVENTION, 2014, 10 (06) : 732 - 738
  • [30] Feasibility and Accuracy of 3DTEE Versus CT for the Evaluation of Aortic Valve Annulus to Left Main Ostium Distance Before Transcatheter Aortic Valve Implantation
    Tamborini, Gloria
    Fusini, Laura
    Gripari, Paola
    Muratori, Manuela
    Cefalu, Claudia
    Maffessanti, Francesco
    Alamanni, Francesco
    Bartorelli, Antonio
    Pontone, Gianluca
    Andreini, Daniele
    Bertella, Erika
    Fiorentini, Cesare
    Pepi, Mauro
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (06) : 579 - 588