Contained aortic annulus rupture with persisting false aneurysm after transfemoral transcatheter aortic valve implantation

被引:7
|
作者
Egenrieder, Stephanie [1 ]
Hill, Stephan [1 ]
Backes, Maik [2 ]
Voehringer, Matthias [3 ]
Sechtem, Udo [1 ]
机构
[1] Robert Bosch Krankenhaus, Abt Kardiol, D-70376 Stuttgart, Germany
[2] Robert Bosch Krankenhaus, Inst Radiol, D-70376 Stuttgart, Germany
[3] CCLB Ludwigsburg, Ludwigsburg, Germany
关键词
Transfemoral transcatheter aortic valve implantation; Aortic annulus rupture; False aneurysm; ROOT;
D O I
10.1007/s00392-014-0696-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
With older age and increasing comorbidities, conventional operative procedures for severe symptomatic aortic stenosis are associated with a high surgical risk. To date, transfemoral transcatheter aortic valve implantation (TF-TAVI) represents an accepted alternative method of intervention with a cardiovascular and all-cause mortality similar to operative replacement at early and long-term follow-up in this high risk population (Thomas et al., Circulation 124:425-433, 2011). Despite growing experience of the operators and improvement of the devices procedural and perioperative complications still occur (Panchal et al., Am J Cardiol, 2013). Aortic annulus rupture as well as the rupture of the membranous ventricular septum has been reported (Aminian et al., Catheter Cardiovasc Interv 81:E72-E75, 2013). We present the unusual case of an 80-year-old female who developed a false aneurysm following a contained aortic annulus rupture during a TF-TAVI procedure.
引用
收藏
页码:599 / 601
页数:3
相关论文
共 50 条
  • [1] Contained aortic annulus rupture with persisting false aneurysm after transfemoral transcatheter aortic valve implantation
    Stephanie Egenrieder
    Stephan Hill
    Maik Backes
    Matthias Vöhringer
    Udo Sechtem
    Clinical Research in Cardiology, 2014, 103 : 599 - 601
  • [2] Aortic annulus rupture and transcatheter aortic valve implantation
    Vanhuyse, Fabrice
    Folliguet, Thierry
    Grandmougin, Daniel
    Elfarra, Mazen
    Moulin, Frederic
    Villemot, Jean-Pierre
    Maureira, Pablo
    ACTA CARDIOLOGICA, 2015, 70 (03) : 371 - 372
  • [3] Aortic Annulus Evaluation in Transcatheter Aortic Valve Implantation
    Hutter, Andrea
    Opitz, Anke
    Bleiziffer, Sabine
    Ruge, Hendrik
    Hettich, Ina
    Mazzitelli, Domenico
    Will, Albrecht
    Tassani, Peter
    Bauernschmitt, Robert
    Lange, Ruediger
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (07) : 1009 - 1019
  • [4] Apical left ventricular false aneurysm after transapical transcatheter aortic valve implantation
    Maillet, Jean-Michel
    Sableyrolles, Jean-Louis
    Guyon, Phillipe
    Bonnet, Nicolas
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (01) : 137 - 138
  • [5] Aortic root volume is associated with contained rupture of the aortic annulus in balloon-expandable transcatheter aortic valve replacement
    Reinoehl, Jochen
    Psyrakis, Dimitrios
    Kaier, Klaus
    Kodirov, Sodikdjon
    Siepe, Matthias
    Gutmann, Anja
    von zur Muehlen, Constantin
    Moser, Martin
    Ahrens, Ingo
    Pache, Gregor
    Zirlik, Andreas
    Langer, Mathias
    Beyersdorf, Friedhelm
    Zehender, Manfred
    Bode, Christoph
    Blanke, Philipp
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (04) : 807 - 817
  • [6] Conservative Management and Resolution of a Contained Rupture of Aortic Annulus Following Transcatheter Valve Replacement
    Subban, Vijayakumar
    Incani, Alexander
    Clarke, Andrew
    Aroney, Constantine
    Scalia, Gregory M.
    Crowhurst, James A.
    Raffel, Owen Christopher
    Walters, Darren L.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (06) : E33 - E34
  • [7] Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis and Small Aortic Annulus
    Kalavrouziotis, Dimitri
    Rodes-Cabau, Josep
    Bagur, Rodrigo
    Doyle, Daniel
    De Larochelliere, Robert
    Pibarot, Philippe
    Dumont, Eric
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (10) : 1016 - 1024
  • [8] Aortic Annulus Rupture During Transcatheter Aortic Valve Implantation (TAVI): One Ounce of Prevention is Worth One Pound of Cure
    Dahdouh, Ziad
    Roule, Vincent
    Lognone, Therese
    Sabatier, Remi
    Grollier, Gilles
    HEART LUNG AND CIRCULATION, 2014, 23 (04): : E127 - E129
  • [9] Successful treatment of a false left ventricular aneurysm after transcatheter aortic valve replacement
    Abe, Noriyuki
    Yamazato, Takahiro
    Munakata, Hiroshi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (04) : 890 - 890
  • [10] Surgical Repair of a Transannular Rupture During Transfemoral Transcatheter Aortic Valve Replacement
    EL-Andari, Ryaan
    Bozso, Sabin J.
    Kang, Jimmy J. H.
    Manikala, Vinod K.
    Moon, Michael C.
    Al-Aklabi, Mohammed
    Welsh, Robert C.
    Nagendran, Jeevan
    CLINICAL MEDICINE INSIGHTS-CASE REPORTS, 2021, 14