Voltammetric determination of atenolol at C60-modified glassy carbon electrodes

被引:83
作者
Goyal, Rajendra N. [1 ]
Singh, Sudhanshu P. [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
voltammetry; atenolol; electrocatalysis; fullerene-C-60; surface coverage;
D O I
10.1016/j.talanta.2005.11.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
C-60-modified glassy carbon electrode has been found to exhibit excellent electrocatalytic activity towards atenolol oxidation for its voltammetric determination at physiological pH. Lowering of overpotential associated with atenolol oxidation indicates electrocatalytic nature of electrode. Determination of atenolol was carried out at pH 7.2 at modified electrode and a well-defined oxidation peak has been observed similar to 1040 mV versus Ag/AgCl electrode for atenolol oxidation. Calibration plot having good co-linearity with a correlation coefficient 0.997 was obtained in the concentration range of 0.25-1.5 mM atenolol and the sensitivity of the method has been found to be 8.58 mu A mM(-1). The detection limit is found to be 0.16 mM. The method developed is applicable for atenolol determination in pharmaceutical preparations and urine samples. The modified electrode showed a good surface coverage (similar to 85%) with C-60. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:932 / 937
页数:6
相关论文
共 23 条
[11]   GROWTH OF CARBON NANOTUBES [J].
IIJIMA, S .
MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 1993, 19 (1-2) :172-180
[12]   C-60 - BUCKMINSTERFULLERENE [J].
KROTO, HW ;
HEATH, JR ;
OBRIEN, SC ;
CURL, RF ;
SMALLEY, RE .
NATURE, 1985, 318 (6042) :162-163
[13]  
Kutner W, 1998, PURE APPL CHEM, V70, P1302
[14]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION APPLIED TO THE SCREENING OF BETA-BLOCKERS IN HUMAN URINE [J].
MAGUREGUI, MI ;
ALONSO, RM ;
JIMENEZ, RM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 674 (01) :85-91
[15]   Kinetics mechanistic and spectral investigation of ruthenium (III)catalysed oxidation of atenolol by alkaline permanganate (stopped-flow technique) [J].
Mulla, RM ;
Hiremath, GC ;
Nandibewoor, ST .
JOURNAL OF CHEMICAL SCIENCES, 2005, 117 (01) :33-42
[16]   A minisensor for the rapid screening of atenolol in pharmaceutical preparations based on surface-stabilized bilayer lipid membranes with incorporated DNA [J].
Nikolelis, DP ;
Petropoulou, SSE ;
Mitrokotsa, MV .
BIOELECTROCHEMISTRY, 2002, 58 (01) :107-112
[17]   Fullerene film electrodes in aqueous solutions [J].
Szucs, A ;
Loix, A ;
Nagy, JB ;
Lamberts, L .
SYNTHETIC METALS, 1996, 77 (1-3) :227-230
[18]   FULLERENE FILM ELECTRODES IN AQUEOUS-SOLUTIONS .1. PREPARATION AND ELECTROCHEMICAL CHARACTERIZATION [J].
SZUCS, A ;
LOIX, A ;
NAGY, JB ;
LAMBERTS, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :191-203
[19]   Electrochemistry on partially reduced fullerene films [J].
Szucs, A ;
Tolgyesi, M ;
Csiszar, M ;
Nagy, JB ;
Novak, M .
ELECTROCHIMICA ACTA, 1998, 44 (04) :613-621
[20]   Electrochemical oxidation of L-cysteine mediated by a fullerene-C60-modified carbon electrode [J].
Tan, WT ;
Bond, AM ;
Ngooi, SW ;
Lim, EB ;
Goh, JK .
ANALYTICA CHIMICA ACTA, 2003, 491 (02) :181-191