Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments

被引:133
作者
Geerse, Daphne J. [1 ,2 ]
Coolen, Bert H. [1 ]
Roerdink, Melvyn [1 ]
机构
[1] Vrije Univ Amsterdam, Dept Human Movement Sci, MOVE Res Inst Amsterdam, Amsterdam, Netherlands
[2] Leiden Univ, Med Ctr, Dept Neurol, Leiden, Netherlands
来源
PLOS ONE | 2015年 / 10卷 / 10期
关键词
XBOX ONE KINECT; CONCURRENT VALIDITY; MICROSOFT KINECT; RELIABILITY; SPEED; BALANCE; EVENTS; PEOPLE; AGREEMENT; PREDICTOR;
D O I
10.1371/journal.pone.0139913
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatchbased time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point's time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point's time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters' walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman's bias and limits of agreement. Body point's time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC >= 0.888), with negligible biases and narrow limits of agreement. Hence, body point's time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner.
引用
收藏
页数:15
相关论文
共 31 条
  • [11] Reliability of gait performance tests in men and women with hemiparesis after stroke
    Flansbjer, UB
    Holmbäck, AM
    Downham, D
    Patten, C
    Lexell, J
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2005, 37 (02) : 75 - 82
  • [12] Gabel Moshe, 2012, Annu Int Conf IEEE Eng Med Biol Soc, V2012, P1964, DOI 10.1109/EMBC.2012.6346340
  • [13] Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease
    Galna, Brook
    Barry, Gillian
    Jackson, Dan
    Mhiripiri, Dadirayi
    Olivier, Patrick
    Rochester, Lynn
    [J]. GAIT & POSTURE, 2014, 39 (04) : 1062 - 1068
  • [14] Assessing walking speed in clinical research: a systematic review
    Graham, James E.
    Ostir, Glenn V.
    Fisher, Steven R.
    Ottenbacher, Kenneth J.
    [J]. JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2008, 14 (04) : 552 - 562
  • [15] Kitsunezaki N, 2013, IEEE INT SYM MED MEA, P294, DOI 10.1109/MeMeA.2013.6549755
  • [16] McGraw KO, 1996, PSYCHOL METHODS, V1, P30, DOI 10.1037/1082-989X.1.4.390
  • [17] Gait assessment using the Microsoft Xbox One Kinect: Concurrent validity and inter-day reliability of spatiotemporal and kinematic variables
    Mentiplay, Benjamin F.
    Perraton, Luke G.
    Bower, Kelly J.
    Pua, Yong-Hao
    McGaw, Rebekah
    Heywood, Sophie
    Clark, Ross A.
    [J]. JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2166 - 2170
  • [18] Gait velocity as a single predictor of adverse events in healthy seniors aged 75 years and older
    Montero-Odasso, M
    Schapira, M
    Soriano, ER
    Varela, M
    Kaplan, R
    Camera, LA
    Mayorga, LM
    [J]. JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2005, 60 (10): : 1304 - 1309
  • [19] Automated Assessment of Upper Extremity Movement Impairment due to Stroke
    Olesh, Erienne V.
    Yakovenko, Sergiy
    Gritsenko, Valeriya
    [J]. PLOS ONE, 2014, 9 (08):
  • [20] Meaningful change and responsiveness in common physical performance measures in older adults
    Perera, Subashan
    Mody, Samir H.
    Woodman, Ricbard C.
    Studenski, Stephanie A.
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2006, 54 (05) : 743 - 749