Micromachined antenna-coupled uncooled microbolometers for terahertz imaging arrays

被引:35
作者
Miller, AJ [1 ]
Luukanen, A [1 ]
Grossman, EN [1 ]
机构
[1] Natl Inst Stand & Technol, Quantum Elect Metrol Div, Boulder, CO 80305 USA
来源
TERAHERTZ FOR MILITARY AND SECURITY APPLICATIONS II | 2004年 / 5411卷
关键词
air-bridge; microbolometer; millimeter-wave; planar antenna; terahertz imaging;
D O I
10.1117/12.543236
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In recent years our group has made significant progress toward the goal of a scalable, inexpensive terahertz imaging system for the detection of weapons concealed under clothing. By actively illuminating the subject under examination with only moderate source power (few milliwatts) the sensitivity constraints on the detector technology are significantly lessened compared to purely passive millimeter-wave detection. Last year, we demonstrated a fully planar, optically lithographed, uncooled terahertz imaging array with 120 pixels on a silicon substrate 75 mm in diameter. In this paper we present the recent progress on improving the responsivity of the individual microbolometers by a simple technique of surface micromachining to reduce the substrate thermal conduction. We describe the microbolometer array fabrication and present results on devices with a measured electrical responsivity of over 85 V/W (electrical NEPapproximate to25 pW/rootHz), an improvement by a factor of two over current substrate-supported bolometers.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 6 条
  • [1] Active millimeter-wave imaging for concealed weapons detection
    Grossman, EN
    Miller, AJ
    [J]. PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY VI AND RADAR SENSOR TECHNOLOGY VII, 2003, 5077 : 62 - 70
  • [2] Concealed weapons detection using an uncooled millimeter-wave microbolometer system
    Grossman, EN
    Bhupathiraju, AK
    Miller, AJ
    Reintsema, CD
    [J]. INFRARED AND PASSIVE MILLIMETER-WAVE IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING, 2002, 4719 : 364 - 369
  • [3] Concealed weapons detection system using uncooled, pulsed, imaging arrays of millimeter-wave bolometers
    Grossman, EN
    Nolen, S
    Paulter, NG
    Reintsema, CD
    [J]. PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY V, 2001, 4373 : 7 - 15
  • [4] GROSSMAN EN, 2004, P SPIE
  • [5] LUUKANEN A, 2004, P SPIE
  • [6] Properties of cavity-backed slot-ring antennas at 95 GHz
    Nolen, S
    Harvey, TE
    Reintsema, CD
    Grossman, EN
    [J]. PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY V, 2001, 4373 : 49 - 57