Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis

被引:10
作者
Bilbao, Arturo [1 ]
Hernandez-De Oliveira, M. [2 ]
Varela-Centelles, Pablo I. [3 ]
Seoane, J. [3 ]
机构
[1] Santiago de Compostela Univ Hosp, Serv Maxillofacial Surg, Santiago De Compostela, Spain
[2] Katherine Hosp, Stuttgart, Germany
[3] Univ Santiago de Compostela, Dept Stomatol, Santiago De Compostela, Spain
关键词
dental implant; osseodistraction; resonance frequency analysis; stability; ALVEOLAR DISTRACTION OSTEOGENESIS; VERTICAL DISTRACTION; CONSOLIDATION PERIOD; GRADUAL DISTRACTION; RIDGE AUGMENTATION; PLACEMENT; DOG; OSTEODISTRACTION; INTERFACE; MAXILLARY;
D O I
10.1111/j.1600-0501.2008.01614.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To determine the implant stability in osseodistraction-generated (ODG) bone after a 2-month consolidation period, assessed by resonance frequency analysis (RFA). Material and methods Twenty healthy, non-smoker female patients received 71 dental implants, 39 placed in native bone and 32 in ODG bone, after an 8-week consolidation period. Primary and secondary stability of the implants was assessed by means of the Osstell((R)) mentor device. The average value of six measurements was considered for the statistical analysis at each time point. Results The age of the patients who received implants in ODG was not significantly different from that of those receiving implants in pristine bone (48.0 +/- 10.9); [X=1.6; 95% confidence interval (CI)=-7.7-10.9]. Although implants placed in both bone types indicated good primary stability, a statistically significant difference in favour of implants placed in pristine bone could be identified in terms of osteogenic distraction (OD) (X-i-X-j=3.4; 95% CI=1.7-5.8). After a 1.5-month integration period, none of the implants failed, but implant stability still recorded higher values for implants located in the pristine bone (X-i-X-j=2.5; 95% CI=0.5-4.4). A positive linear correlation could be established between the implant stability quotient (ISQ) values at implant placement (primary stability) and the post-integration ISQ score (secondary stability) for both bone types, but only 16% of the post-integration ISQ in the ODG bone could be attributed to the primary stability. Conclusions Within the limitations of this study, OD bone offers - after a 2-month consolidation period - high primary and secondary stabilities after implant placement. To cite this article:Bilbao A, Hernandez-De Oliveira M, Varela-Centelles P, Seoane J. Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis.Clin. Oral Impl. Res. 20, 2009; 772-777.doi: 10.1111/j.1600-0501.2008.01614.x.
引用
收藏
页码:772 / 777
页数:6
相关论文
共 50 条
  • [41] Implant Primary Stability Determined by Resonance Frequency Analysis: Correlation With Insertion Torque, Histologic Bone Volume, and Torsional Stability at 6 Weeks
    Makary, Christian
    Rebaudi, Alberto
    Sammartino, Gilberto
    Naaman, Nada
    [J]. IMPLANT DENTISTRY, 2012, 21 (06) : 474 - 480
  • [42] Effects of the 3D bone-to-implant contact and bone stiffness on the initial stability of a dental implant: micro-CT and resonance frequency analyses
    Hsu, J-T
    Huang, H-L
    Tsai, M-T
    Wu, A. Y-J
    Tu, M-G
    Fuh, L-J
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 42 (02) : 276 - 280
  • [43] Factors influencing resonance frequency analysis assessed by Osstell™mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length
    Sim, Christina P. C.
    Lang, Niklaus P.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (06) : 598 - 604
  • [44] Bone graft substitutes and dental implant stability in immediate implant surgery: a systematic review and meta-analysis
    Vanka, Shanthi
    Abul Kasem, Fatima
    Kailani, Tasnem
    Wali, Othman
    Vanka, Amit
    [J]. EVIDENCE-BASED DENTISTRY, 2024, : 70 - 70
  • [45] Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis
    Tanaka, Kenko
    Sailer, Irena
    Iwama, Ryosuke
    Yamauchi, Kensuke
    Nogami, Shinnosuke
    Yoda, Nobuhiro
    Takahashi, Tetsu
    [J]. JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (06) : 360 - 372
  • [46] Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
    Turkyilmaz, I.
    Toezuem, T. F.
    Tumer, C.
    Ozbek, E. N.
    [J]. JOURNAL OF ORAL REHABILITATION, 2006, 33 (12) : 881 - 888
  • [47] Awareness on resonance frequency analysis in dental implantology among dental practitioners and dental students
    Sharma, M. Neha
    Ahmed, Nabeel
    Ganapathy, Dhanraj M.
    Pandurangan, Kiran Kumar
    Maiti, Subhabrata
    [J]. JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S233 - S237
  • [48] Comparison of dental implant stabilities by impact response and resonance frequencies using artificial bone
    Kim, Dae-Seung
    Lee, Woo-Jin
    Choi, Soon-Chul
    Lee, Sam-Sun
    Heo, Min-Suk
    Huh, Kyung-Hoe
    Kim, Tae-Il
    Yi, Won-Jin
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (06) : 715 - 720
  • [49] Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects:: an in vitro study
    Tozum, T. F.
    Turkyilmaz, I.
    McGlumphy, E. A.
    [J]. JOURNAL OF ORAL REHABILITATION, 2008, 35 (10) : 739 - 744
  • [50] Monitoring the change in resonance frequency of a dental implant in hardening dental plaster using microcontroller
    Chowdhury, Debasish
    Goswami, Bhaswati
    Ghosh, Ratna
    [J]. 2014 FOURTH INTERNATIONAL CONFERENCE OF EMERGING APPLICATIONS OF INFORMATION TECHNOLOGY (EAIT), 2014, : 89 - 92