Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis

被引:10
|
作者
Bilbao, Arturo [1 ]
Hernandez-De Oliveira, M. [2 ]
Varela-Centelles, Pablo I. [3 ]
Seoane, J. [3 ]
机构
[1] Santiago de Compostela Univ Hosp, Serv Maxillofacial Surg, Santiago De Compostela, Spain
[2] Katherine Hosp, Stuttgart, Germany
[3] Univ Santiago de Compostela, Dept Stomatol, Santiago De Compostela, Spain
关键词
dental implant; osseodistraction; resonance frequency analysis; stability; ALVEOLAR DISTRACTION OSTEOGENESIS; VERTICAL DISTRACTION; CONSOLIDATION PERIOD; GRADUAL DISTRACTION; RIDGE AUGMENTATION; PLACEMENT; DOG; OSTEODISTRACTION; INTERFACE; MAXILLARY;
D O I
10.1111/j.1600-0501.2008.01614.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To determine the implant stability in osseodistraction-generated (ODG) bone after a 2-month consolidation period, assessed by resonance frequency analysis (RFA). Material and methods Twenty healthy, non-smoker female patients received 71 dental implants, 39 placed in native bone and 32 in ODG bone, after an 8-week consolidation period. Primary and secondary stability of the implants was assessed by means of the Osstell((R)) mentor device. The average value of six measurements was considered for the statistical analysis at each time point. Results The age of the patients who received implants in ODG was not significantly different from that of those receiving implants in pristine bone (48.0 +/- 10.9); [X=1.6; 95% confidence interval (CI)=-7.7-10.9]. Although implants placed in both bone types indicated good primary stability, a statistically significant difference in favour of implants placed in pristine bone could be identified in terms of osteogenic distraction (OD) (X-i-X-j=3.4; 95% CI=1.7-5.8). After a 1.5-month integration period, none of the implants failed, but implant stability still recorded higher values for implants located in the pristine bone (X-i-X-j=2.5; 95% CI=0.5-4.4). A positive linear correlation could be established between the implant stability quotient (ISQ) values at implant placement (primary stability) and the post-integration ISQ score (secondary stability) for both bone types, but only 16% of the post-integration ISQ in the ODG bone could be attributed to the primary stability. Conclusions Within the limitations of this study, OD bone offers - after a 2-month consolidation period - high primary and secondary stabilities after implant placement. To cite this article:Bilbao A, Hernandez-De Oliveira M, Varela-Centelles P, Seoane J. Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis.Clin. Oral Impl. Res. 20, 2009; 772-777.doi: 10.1111/j.1600-0501.2008.01614.x.
引用
收藏
页码:772 / 777
页数:6
相关论文
共 50 条
  • [21] Influence of the orientation of the Osstell® transducer during measurement of dental implant stability using resonance frequency analysis: A numerical approach
    Capek, Lukas
    Simunek, Antonin
    Slezak, Radovan
    Dzan, Ladislav
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (07) : 764 - 769
  • [22] Assessment of the Primary Stability of Dental Implants in Artificial Bone Using Resonance Frequency and Percussion Analyses
    Ahmad, Omaid K.
    Kelly, Robert
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 89 - 95
  • [23] Influence of Osseointegration Degree and Pattern on Resonance Frequency in the Assessment of Dental Implant Stability Using Finite Element Analysis
    Deng, Bin
    Tan, Keson B.
    Liu, Gui Rong
    Lu, Yi
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (06) : 1082 - 1088
  • [24] The effects of implant angulation on the resonance frequency of a dental implant
    Harirforoush, R.
    Arzanpour, S.
    Chehroudi, B.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (08) : 1024 - 1032
  • [25] RESONANCE FREQUENCY DETECTION OF DENTAL IMPLANT STABILITY WITH VARIOUS BONE DEFECTS: IN-VITRO EXPERIMENTS
    Zhuang, H-B
    Chen, Ch-S
    Lee, S-Y
    Pan, M-Ch
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, VOL 1, PTS A AND B, 2010, : 765 - 772
  • [26] The evaluation of implant stability measured by resonance frequency analysis in different bone types
    Sargolzaie, Naser
    Samizade, Sarah
    Arab, Hamidreza
    Ghanbari, Habibollah
    Khodadadifard, Leila
    Khajavi, Amin
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2019, 45 (01) : 29 - 33
  • [27] Efficacy of Resonance Frequency Analysis in the Diagnosis of Compromised Bone-Implant Interface
    Cavusoglu, Yeliz
    Sahin, Erdal
    Akca, Kivanc
    IMPLANT DENTISTRY, 2012, 21 (05) : 394 - 398
  • [28] Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    Annette Rabel
    Steffen Gerhard Köhler
    Andrea Maria Schmidt-Westhausen
    Clinical Oral Investigations, 2007, 11 : 257 - 265
  • [29] Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    Rabel, Annette
    Koehler, Steffen Gerhard
    Schmidt-Westhausen, Andrea Maria
    CLINICAL ORAL INVESTIGATIONS, 2007, 11 (03) : 257 - 265
  • [30] Dental Implant Surface Topography and Stability With Resonance Frequency Analysis: An Overview and Case Report
    Dhalla, Nipun
    Palwankar, Pooja
    Gopal, Lipika
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)