Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis

被引:10
|
作者
Bilbao, Arturo [1 ]
Hernandez-De Oliveira, M. [2 ]
Varela-Centelles, Pablo I. [3 ]
Seoane, J. [3 ]
机构
[1] Santiago de Compostela Univ Hosp, Serv Maxillofacial Surg, Santiago De Compostela, Spain
[2] Katherine Hosp, Stuttgart, Germany
[3] Univ Santiago de Compostela, Dept Stomatol, Santiago De Compostela, Spain
关键词
dental implant; osseodistraction; resonance frequency analysis; stability; ALVEOLAR DISTRACTION OSTEOGENESIS; VERTICAL DISTRACTION; CONSOLIDATION PERIOD; GRADUAL DISTRACTION; RIDGE AUGMENTATION; PLACEMENT; DOG; OSTEODISTRACTION; INTERFACE; MAXILLARY;
D O I
10.1111/j.1600-0501.2008.01614.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To determine the implant stability in osseodistraction-generated (ODG) bone after a 2-month consolidation period, assessed by resonance frequency analysis (RFA). Material and methods Twenty healthy, non-smoker female patients received 71 dental implants, 39 placed in native bone and 32 in ODG bone, after an 8-week consolidation period. Primary and secondary stability of the implants was assessed by means of the Osstell((R)) mentor device. The average value of six measurements was considered for the statistical analysis at each time point. Results The age of the patients who received implants in ODG was not significantly different from that of those receiving implants in pristine bone (48.0 +/- 10.9); [X=1.6; 95% confidence interval (CI)=-7.7-10.9]. Although implants placed in both bone types indicated good primary stability, a statistically significant difference in favour of implants placed in pristine bone could be identified in terms of osteogenic distraction (OD) (X-i-X-j=3.4; 95% CI=1.7-5.8). After a 1.5-month integration period, none of the implants failed, but implant stability still recorded higher values for implants located in the pristine bone (X-i-X-j=2.5; 95% CI=0.5-4.4). A positive linear correlation could be established between the implant stability quotient (ISQ) values at implant placement (primary stability) and the post-integration ISQ score (secondary stability) for both bone types, but only 16% of the post-integration ISQ in the ODG bone could be attributed to the primary stability. Conclusions Within the limitations of this study, OD bone offers - after a 2-month consolidation period - high primary and secondary stabilities after implant placement. To cite this article:Bilbao A, Hernandez-De Oliveira M, Varela-Centelles P, Seoane J. Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis.Clin. Oral Impl. Res. 20, 2009; 772-777.doi: 10.1111/j.1600-0501.2008.01614.x.
引用
收藏
页码:772 / 777
页数:6
相关论文
共 50 条
  • [1] Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach
    Huang, HM
    Lee, SY
    Yeh, CY
    Lin, CT
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (01) : 65 - 74
  • [2] Torsional resonance frequency analysis: a novel method for assessment of dental implant stability
    Tang, Yu-Long
    Li, Bing
    Jin, Wei
    Li, De-Hua
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (06) : 615 - 622
  • [3] Measurement of dental implant stability by resonance frequency analysis: A review of the literature
    Pilar Quesada-Garcia, Ma
    Prados-Sanchez, Estrella
    Victoria Olmedo-Gaya, Ma
    Munoz-Soto, Esther
    Paloma Gonzalez-Rodriguez, Ma
    Vallecillo-Capilla, Manuel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (10): : E538 - E546
  • [4] Assessment of dental implant stability using resonance frequency analysis and quantitative ultrasound methods
    Heriveaux, Yoann
    Vayron, Romain
    Fraulob, Manon
    Lomami, Hugues Albini
    Lenormand, Camille
    Haiat, Guillaume
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (03) : 421 - 427
  • [5] Resonance frequency analysis of dental implant stability during the healing period
    Boronat Lopez, Araceli
    Balaguer Martinez, Jose
    Lamas Pelayo, Joana
    Carrillo Garcia, Celia
    Penarrocha Diago, Miguel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (04): : E244 - E247
  • [6] A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant
    Pan, Min-Chun
    Zhuang, Han-Bo
    Chen, Chin-Sung
    Wu, Jer-Whey
    Lee, Shyh-Yuan
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (12) : 1825 - 1830
  • [7] Challenges of Using Resonance Frequency Analysis to Identify Stability of a Dental Implant Placed in the Mandible
    Liu, Yifeng
    Sorensen, John
    Shen, I
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : E7 - E21
  • [8] Early Detection of Alterations in the Resonance Frequency Assessment of Oral Implant Stability on Various Bone Types: A Clinical Study
    Sencimen, Metin
    Gulses, Aydin
    Ozen, Julide
    Dergin, Cem
    Okçu, Kemal Murat
    Ayyildiz, Simel
    Altug, Hasan Ayberk
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (04) : 411 - 419
  • [9] A simple mathematical model for the resonance frequency analysis of dental implant stability: Implant clamping quotient
    Argatov, Ivan
    Iantchenko, Alexei
    MECHANICS RESEARCH COMMUNICATIONS, 2019, 95 : 67 - 70
  • [10] Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis
    Vayron, Romain
    Vu-Hieu Nguyen
    Lecuelle, Benoit
    Haiat, Guillaume
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) : 470 - 478