Energy performance of photovoltaic (PV) windows under typical climates of China in terms of transmittance and orientation

被引:62
作者
Guo, Wenwen [1 ]
Kong, Li [2 ]
Chow, Tintai [3 ]
Li, Chunying [4 ]
Zhu, Qunzhi [1 ]
Qiu, Zhongzhu [1 ]
Li, Lin [1 ]
Wang, Yalin [1 ]
Riffat, Saffa B. [5 ]
机构
[1] Shanghai Univ Elect Power, Coll Energy & Mech Engn, Shanghai, Peoples R China
[2] Meteorol Bur Jiading Dist, Shanghai, Peoples R China
[3] City Univ Hong Kong, Div Bldg Sci & Technol, Hong Kong, Peoples R China
[4] Shenzhen Univ, Sch Architecture & Urban Planning, Shenzhen, Peoples R China
[5] Univ Nottingham, Dept Architecture & Built Environm, Nottingham, England
关键词
Photovoltaic (PV) window; Building simulation; Building energy conservation; Climate region; SEMITRANSPARENT PV; DAYLIGHT PERFORMANCE; SIMULATION; OPTIMIZATION; FACADES; SYSTEM;
D O I
10.1016/j.energy.2020.118794
中图分类号
O414.1 [热力学];
学科分类号
摘要
PV windows provide thermal insulation, daylight use and power generation simultaneously. Present investigation aimed to evaluate the energy performance of 3 types of PV windows under 5 climates of China, and particularly to clarify the influences of transmittance and orientation on its energy performance. The present work involves: (i)the experimental testing that had been carried out; (ii)validation of the EnergyPlus model of natural ventilated double PV (NVDPV) window; (iii) prediction of the energy performance of the 5 PV windows under typical climates of China based on the validated model; (iv) applicability discussion of the PV windows under different climates and influence of transmittance and orientation. The results reveal the highest energy saving rate obtained by NVDPV window in the 5 cities. The NVDPV window integrated PV glass with transmittance of 10% delivered better energy performance than the window with transmittance of 5% under climates of Harbin, Beijing, Shanghai and Shenzhen. The south facing windows achieved least building electricity consumption under the climates of Harbin, Beijing, Shanghai, and Lhasa. Exceptionally, the east facing windows achieved least electricity usage under the climate of Shenzhen. The achievements from the present work provide a reliable criterion for the optimized design of PV windows. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 37 条
[1]   Experimental validation of a EnergyPlus model: Application of a multi-storey naturally ventilated double skin facade [J].
Andelkovic, Aleksandar S. ;
Mujan, Igor ;
Dakic, Stojanka .
ENERGY AND BUILDINGS, 2016, 118 :27-36
[2]  
[Anonymous], 2010, EnergyPlus Engineering Reference, the Reference to EnergyPlus Calculations
[3]  
[Anonymous], 2007, Performance based building energy code
[4]   Assessment of the efficiency of window integrated CdTe based semi-transparent photovoltaic module [J].
Barman, Sankar ;
Chowdhury, Amartya ;
Mathur, Sanjay ;
Mathur, Jyotirmay .
SUSTAINABLE CITIES AND SOCIETY, 2018, 37 :250-262
[5]  
Cecilia Guillen, 2017, INT RES C SUST EN EN
[6]   Evaluating the electricity saving potential of electrochromic glazing for cooling and lighting at the scale of the Swiss non-residential national building stock using a Monte Carlo model [J].
Chambers, Jonathan ;
Hollmuller, Pierre ;
Bouvard, Olivia ;
Schueler, Andreas ;
Scartezzini, Jean-Louis ;
Azar, Elie ;
Patel, Martin K. .
ENERGY, 2019, 185 :136-147
[7]   Experimental and numerical evaluation of the crystalline silicon PV window under the climatic conditions in southwest China [J].
Chen, Mo ;
Zhang, Wei ;
Xie, Lingzhi ;
Ni, Zhichun ;
Wei, Qingzhu ;
Wang, Wei ;
Tian, Hao .
ENERGY, 2019, 183 :584-598
[8]   Potential application of "see-through" solar cells in ventilated glazing in Hong Kong [J].
Chow, Tin-Tai ;
Qiu, Zhongzhu ;
Li, Chunying .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2009, 93 (02) :230-238
[9]   System analysis of a multifunctional PV/T hybrid solar window [J].
Davidsson, Henrik ;
Perers, Bengt ;
Karlsson, Bjorn .
SOLAR ENERGY, 2012, 86 (03) :903-910
[10]   Semi-transparent PV windows: A study for office buildings in Brazil [J].
Didone, Evelise Leite ;
Wagner, Andreas .
ENERGY AND BUILDINGS, 2013, 67 :136-142