Fabrication of a planar-form screen-printed solid electrolyte modified Ag/AgCl reference electrode for application in a potentiometric biosensor

被引:69
|
作者
Liao, Wei-Yin [1 ]
Chou, Tse-Chuan [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Chem Engn, Tainan 70101, Taiwan
关键词
D O I
10.1021/ac051562+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study features the fabrication of a planar-form, solid electrolyte modified, (PSEM) Ag/AgCl reference electrode using a screen-printing method. The PSEM Ag/AgCl reference electrode uses agar gel as the inner electrolyte and chloroprene rubber for the liquid junction and insulator. These common low-cost materials and the simple fabrication processes involved render the proposed reference electrode an ideal candidate for cost-efficient mass production. It is shown that the developed reference electrode is insensitive to most of the physiologically important ionic species, including Na+, K+, Li+, Ca2+, NH4+, and Cl-, under continuous measurement conditions. Moreover, as with conventional commercial reference electrodes, the proposed reference electrode exhibits a reversible response, which is maintained until the agar gel dries out. The PSEM Ag/AgCl reference electrode is integrated with an iridium oxide modified Pt-based pH indicator electrode to form a chip-type pH biosensor. The performance of this biosensor is consistent with that obtained from a pH meter based on a macroscopic commercial Ag/AgCl reference electrode. The experimental results confirm that the proposed biosensor is capable of providing precise pH measurements of various real samples. Accordingly, the PSEM Ag/AgCl reference electrode presented in this study provides a viable alternative to the macroscopic Ag/AgCl reference electrode used in many conventional chip-based pH sensors.
引用
收藏
页码:4219 / 4223
页数:5
相关论文
共 50 条
  • [1] Fabrication and Characterization of Planar Screen-Printed Ag/AgCl Reference Electrode for Disposable Sensor Strip
    Idegami, Koutarou
    Chikae, Miyuki
    Nagatani, Naoki
    Tamiya, Eiichi
    Takamura, Yuzuru
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (09)
  • [2] Fabrication of a Simple and Cheap Screen-Printed Silver/Silver Chloride (Ag/AgCl) Quasi-Reference Electrode
    Ferreira Oliveira, Ana Elisa
    Pereira, Arnaldo Cesar
    Campos de Resende, Mayra Asevedo
    Ferreira, Lucas Franco
    ELECTROANALYSIS, 2022, 34 (05) : 809 - 819
  • [3] A screen-printed Ag/AgCl reference electrode with long-term stability for electroanalytical applications
    Dawkins, Rebecca C.
    Wen, Dingchen
    Hart, Judy N.
    Vepsalainen, Mikko
    ELECTROCHIMICA ACTA, 2021, 393
  • [4] Preliminary Study on the Fabrication of Multi-Layer Screen-Printed Electrode for Biosensor Application
    Alfarobi, Habib
    Yulianti, Elly Septia
    Intan, Nurul
    Whulanza, Yudan
    Park, Don-Hee
    Rahman, Siti Fauziyah
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2022, 13 (08) : 1692 - 1703
  • [5] Washable and Flexible Screen-Printed Ag/AgCl Electrode on Textiles for ECG Monitoring
    Tu, Huating
    Li, Xiaoou
    Lin, Xiangde
    Lang, Chenhong
    Gao, Yang
    POLYMERS, 2023, 15 (18)
  • [6] A review of screen-printed silver/silver chloride (Ag/AgCl) reference electrodes potentially suitable for environmental potentiometric sensors
    Sophocleous, Marios
    Atkinson, John K.
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 267 : 106 - 120
  • [7] Planer-type liquid junction Ag/AgCl reference electrode and its application in a potentiometric biosensor
    Liao, WY
    Lin, HY
    Chou, TC
    2005 IEEE 31ST ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2005, : 225 - 226
  • [8] Improvement in the long-term stability of screen-printed planar type solid-state Ag/AgCl reference electrode by introducing poly(dimethylsiloxane) liquid junction
    Shitanda, Isao
    Kiryu, Hiroyuki
    Itagaki, Masayuki
    ELECTROCHIMICA ACTA, 2011, 58 : 528 - 531
  • [9] Study of Fabrication Conditions of ATP Biosensor based on Screen-printed Electrode
    Zhu, Qin
    Liang, Bo
    Pei, Yanchuang
    Ye, Xuesong
    Liang, Xiao
    2016 IEEE SENSORS, 2016,
  • [10] THE FABRICATION AND PERFORMANCE OF A AG/AGCL REFERENCE ELECTRODE IN THIONYL CHLORIDE ELECTROLYTE
    CIESLAK, WR
    DELNICK, FM
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (01) : 132 - 134