Improving the signal data acquisition in condition monitoring of electrical machines

被引:29
作者
Costa, FF [1 ]
de Almeida, LAL
Naidu, SR
Braga-Filho, ER
机构
[1] Univ Fed Campina Grande, Dept Engn Eletr, BR-58109970 Campinas Grande, Brazil
[2] Univ Fed Bahia, Dept Elect Engn, BR-40210630 Salvador, BA, Brazil
关键词
condition monitoring; induction motor; motor current signature analysis (MCSA); preventive maintenance;
D O I
10.1109/TIM.2004.830740
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The occurrence of a broken bar in induction machines causes an internal magnetic imbalance, which is reflected in the stator current. This effect may be detected by estimating the spectral signature of the stator current, particularly the sidebands around the fundamental frequency. However, the fundamental 60-Hz amplitude is considerably greater than the sideband amplitude, which usually requires an analog 60-Hz notch filter in the data acquisition system. Analog filters are sensitive to temperature variations, which, in this case, may shift the filter resonance frequency and degrade the desired response. It is proposed in this paper that the analog notch filter may be replaced by a digital/analog cancelling technique based on the recursive discrete-time Fourier transform. The technique is shown to attenuate the fundamental 60-Hz amplitude considerably before A/D conversion, leaving only the sidebands in the current signal.