Evaluation of Approaches to Characterize Seismic Isolation Systems for Design

被引:14
作者
Sayani, Prayag J. [1 ]
Ryan, Keri L. [1 ]
机构
[1] Utah State Univ, Dept Civil & Environm Engn, Logan, UT 84322 USA
关键词
Base Isolation; Equivalent Linear Analysis; Effective Period; Effective Damping; Nonlinear Response; Normalized Strength; BASE-ISOLATED STRUCTURES; ISOLATION DEVICES; BRIDGES; SPECTRA;
D O I
10.1080/13632460802715057
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Current design codes generally use an equivalent linear approach for preliminary design of a seismic isolation system. The equivalent linear approach is based on effective parameters, rather than physical parameters of the system, and may not accurately account for the nonlinearity of the isolation system. This article evaluates an alternative normalized strength characterization against the equivalent linear characterization. Considerations for evaluation include: (1) ability to effectively account for variations in ground motion intensity; (2) ability to effectively describe the energy dissipation capacity of the isolation system; and (3) conducive to developing design equations that can be implemented within a code framework.
引用
收藏
页码:835 / 851
页数:17
相关论文
共 18 条
[1]  
Anderson E., 1998, P 6 US NAT C EARTHQ
[2]  
ASCE (American Society of Civil Engineers), 2005, ASCE 7 05 MIN DES LO
[3]   Evaluation of NSP to estimate seismic deformation: SDF systems [J].
Chopra, AK ;
Goel, RK .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (04) :482-490
[4]   Comprehensive evaluation of equivalent linear analysis method for seismic-isolated structures represented by sdof systems [J].
Dicleli, Murat ;
Buddaram, Srikanth .
ENGINEERING STRUCTURES, 2007, 29 (08) :1653-1663
[5]  
Fajfar P, 1999, EARTHQ ENG STRUCT D, V28, P979, DOI 10.1002/(SICI)1096-9845(199909)28:9<979::AID-EQE850>3.0.CO
[6]  
2-1
[7]   On the accuracy of simplified methods for the analysis of isolated bridges [J].
Franchin, P ;
Monti, G ;
Pinto, PE .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (03) :363-382
[8]  
Hwang J.S., 1995, Proc. of the 4th U.S. Conference on Lifeline Earthquake Engineering, P416
[9]   Evaluation of equivalent linear analysis methods of bridge isolation [J].
Hwang, JS .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (08) :972-976
[10]  
ICC (International Code Council), 2006, International building code (IBC)