Polyamidoxime-based membranes for the rapid screening of uranium isotopes in water

被引:5
作者
Darge, Abenazer W. [1 ,3 ]
DeVol, Timothy A. [2 ,3 ]
Husson, Scott M. [1 ,3 ]
机构
[1] Clemson Univ, Dept Chem & Biomol Engn, 127 Earle Hall, Clemson, SC 29634 USA
[2] Clemson Univ, Dept Environm Engn & Earth Sci, 342 Comp Court, Anderson, SC 29625 USA
[3] Clemson Univ, Ctr Nucl Environm Engn Sci & Radioact Waste Manage, Clemson, SC 29634 USA
关键词
Alphaspectrometry; Functionalizedmembrane; Isotopicanalysis; Nuclearforensics; Polyacrylonitrile; SURFACE MODIFICATION; MAGNETIC SEPARATION; ALPHA-SPECTROMETRY; AQUEOUS-SOLUTION; POLYACRYLONITRILE; CARBON; SPECTROSCOPY; ADSORPTION; EXTRACTION; COMPOSITE;
D O I
10.1016/j.aca.2022.339997
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditional radiochemistry approaches for the detection of trace-level alpha-emitting radioisotopes in water require lengthy offsite sample preparations and do not lend themselves to rapid quantification. Therefore, a novel platform is needed that combines onsite purification, concentration, and isotopic screening with a fieldable detection system. This contribution describes the synthesis and characterization of polyamidoxime membranes for isolation and concentration of uranium from aqueous matrices, including high-salinity seawater. The aim was to develop a field portable screening method for the rapid quantification of isotopic distribution by alpha spectroscopy. Membranes with varying degree of modification were prepared by chemical conversion of nitrile groups to amidoxime groups on the surface of polyacrylonitrile ultrafiltration (UFPAN) membranes. Attenuated total reflectance Fourier-transform infrared spectroscopy was used to analyze changes in surface chemistry. Flow through filtration experiments conducted using deionized (DI) water and simulated seawater solutions indicated that the modified membrane was effective in capturing more than 95% of the uranium in the solution prior to breakthrough even in the presence of salt ions. Batch uptake experiments were conducted and compared with the flow through experimental data to elucidate likely binding mechanisms. Alpha spectra of uranium loaded membranes were analyzed, and the effects of solution matrix and degree of modification on peak energy resolution were studied. Peak energy resolutions of 24 +/- 2 keV and 32 +/- 6 keV full width at half maximum (FWHM) were obtained by loading uranium from DI and seawater solutions onto modified membranes. Full width at 10% maximum of the same spectra were calculated to be 63 +/- 9 keV and 160 +/- 34 keV to quantify differences seen in peak tailing. Calculations performed based on the results show that it would take less than 3 h of analysis time to screen a sample provided enough volumes of solution are available. This work offers a facile method to prepare Polyamidoxime-based membranes for the rapid screening of uranium isotopes in water
引用
收藏
页数:11
相关论文
共 48 条
  • [31] Surface Modification of Polyacrylonitrile Membrane by Chemical Reaction and Physical Coating: Comparison between Static and Pore-Flowing Procedures
    Qin, Yang
    Yang, Hu
    Xu, Zhenliang
    Li, Feng
    [J]. ACS OMEGA, 2018, 3 (04): : 4231 - 4241
  • [32] Basic characterization of 233U:: Determination of age and 232U content using sector field ICP-MS, gamma spectrometry and alpha spectrometry
    Rameback, H.
    Nygren, U.
    Lagerkvist, P.
    Verbruggen, A.
    Wellum, R.
    Skarnemark, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (05) : 807 - 812
  • [33] Electrospinning synthesis of porous Al2O3 nanofibers by pluronic P123 triblock copolymer surfactant and properties of uranium (VI)-sorption
    Ren, Bo
    Fan, Meiqing
    Tan, Lichao
    Li, Rumin
    Song, Dalei
    Liu, Qi
    Wang, Jun
    Zhang, Bin
    Jing, Xiaoyan
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2016, 177 : 190 - 197
  • [34] Relationship between isotopic uranium activities and total uranium at various uranium enrichments
    Rucker, TL
    Johnson, CM
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 235 (1-2) : 47 - 52
  • [35] One step sample treatment and loading using a deep eutectic solvent immobilized in a porous substrate for thermal ionization mass spectrometry of Pu(iv) ions
    Shah, Raju, V
    Pandey, Ashok K.
    Kumar, S. Jagadish
    Paul, Sumana
    Rao, Radhika M.
    Jaison, P. G.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (10) : 2315 - 2321
  • [36] Robust flexible poly(amidoxime) porous network membranes for highly efficient uranium extraction from seawater
    Shi, Se
    Qian, Yongxin
    Mei, Pingping
    Yuan, Yihui
    Jia, Na
    Dong, Mengyao
    Fan, Jincheng
    Guo, Zhanhu
    Wang, Ning
    [J]. NANO ENERGY, 2020, 71 (71)
  • [37] Rapid extraction of uranium ions from seawater using novel porous polymeric adsorbents
    Sihn, Y. H.
    Byun, J.
    Patel, H. A.
    Lee, W.
    Yavuz, C. T.
    [J]. RSC ADVANCES, 2016, 6 (51): : 45968 - 45976
  • [38] Effective separation of uranium from mine process effluents using chitosan as a recyclable natural adsorbent
    Szlachta, Malgorzata
    Neitola, Raisa
    Peraniemi, Sirpa
    Vepsalainen, Jouko
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 253
  • [39] Tang ML, 2018, ENVIRON SCI-NANO, V5, P2304, DOI [10.1039/c8en00761f, 10.1039/C8EN00761F]
  • [40] Self-assembled biogenic melanin modulated surface chemistry of biopolymers-colloidal silica composite porous matrix for the recovery of uranium
    Tripathi, A.
    Melo, J. S.