We have assessed the value of using a simple apparatus, the Carpal Box, in patients with suspected scaphoid fracture, to produce elongated and magnified radiographs of the carpus. The interobserver agreement between 60 observers of standard scaphoid radiographs and longitudinal and transverse Carpal Box radiographs (X-CB) was compared in 11 patients. Three-phase bone scanning was used as a comparative standard, If at least 75% of the observers agreed and the result was confirmed by three-phase bone scanning, the outcome was termed reliable, Scaphoid radiographs and the longitudinal X-CB films were reliable in four patients and the transverse X-CB films in six patients. The bone scan suggested a scaphoid fracture in five of the 11 patients. Agreement in the interpretation of the standard scaphoid radiographs was acceptable in only 36% of patients: in interpretation of transverse Carpal Box radiographs this figure increased to 55%.
引用
收藏
页码:535 / 539
页数:5
相关论文
共 18 条
[1]   SUSPECTED SCAPHOID FRACTURES - THE VALUE OF RADIOGRAPHS [J].
DIAS, JJ ;
THOMPSON, J ;
BARTON, NJ ;
GREGG, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :98-101
[2]   RADIOGRAPHIC SIGNS OF UNION OF SCAPHOID FRACTURES - AN ANALYSIS OF INTER-OBSERVER AGREEMENT AND REPRODUCIBILITY [J].
DIAS, JJ ;
TAYLOR, M ;
THOMPSON, J ;
BRENKEL, IJ ;
GREGG, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (02) :299-301
[3]  
DUNN AW, 1972, SURG CLIN N AM, V52, P1513
[4]  
Fleiss JL, 1981, STATISTICAL METHODS, P211, DOI DOI 10.2307/2530193
[5]  
Ganel A, 1979, J Hand Surg Am, V4, P540
[6]   SCANNING AND RADIOLOGY OF THE CARPAL SCAPHOID BONE [J].
JORGENSEN, TM ;
ANDRESEN, JH ;
THOMMESEN, P ;
HANSEN, HH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1979, 50 (06) :663-665
[7]   NOTE ON THE SAMPLING ERROR OF THE DIFFERENCE BETWEEN CORRELATED PROPORTIONS OR PERCENTAGES [J].
McNemar, Quinn .
PSYCHOMETRIKA, 1947, 12 (02) :153-157
[8]   ANGLED RADIOGRAPHIC VIEW OF THE WRIST FOR DIAGNOSIS OF FRACTURES OF THE CARPAL SCAPHOID [J].
PROUBASTA, I ;
LLUCH, A ;
CELAYA, F ;
DONCEL, A ;
MATA, JM ;
DONOSO, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (01) :196-196
[9]   ISOTOPE BONE IMAGING IN SUSPECTED SCAPHOID TRAUMA [J].
ROLFE, EB ;
GARVIE, NW ;
KHAN, MA ;
ACKERY, DM .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (645) :762-767
[10]  
RUBY L, 1992, SKELETAL TRAUMA, P1025