Photoplethysmography and nociception

被引:77
作者
Korhonen, I. [1 ,2 ]
Yli-Hankala, A. [2 ,3 ]
机构
[1] VTT Tech Res Ctr Finland, FIN-33101 Tampere, Finland
[2] Tampere Univ Hosp, Dept Anaesthesia, Tampere, Finland
[3] Univ Tampere, Sch Med, FIN-33101 Tampere, Finland
关键词
SKIN VASOMOTOR REFLEX; SURGICAL STRESS INDEX; PLETHYSMOGRAPHIC WAVE-FORM; MULTIPLE NOXIOUS STIMULI; GENERAL-ANESTHESIA; HEART-RATE; ISOFLURANE/OXYGEN ANESTHESIA; HEMODYNAMIC-RESPONSES; BLOOD-VOLUME; PULSE-WAVE;
D O I
10.1111/j.1399-6576.2009.02026.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Photoplethysmography (PPG), i.e. pulse oximetric wave, is a non-invasive technique that is used in anaesthesia monitoring primarily to monitor blood oxygenation. The PPG waveform resembles that of the arterial blood pressure but instead of pressure it is related to the volume changes in the measurement site and hence contains information related to the peripheral blood circulation, including skin vasomotion, which is controlled by the sympathetic nervous system. Because of this link, skin vasomotor response and PPG amplitude response have been associated with nociception under general anaesthesia. Recently, there has been interest in monitoring nociception during general anaesthesia. In many of the published studies, PPG waveform information has been included. The focus of this topical review is to provide an overview on the information embedded in the PPG waveform especially in the context of the autonomic nervous system and analgesia monitoring.
引用
收藏
页码:975 / 985
页数:11
相关论文
共 42 条
[11]   Monitoring analgesia [J].
Guignard, Bruno .
BEST PRACTICE & RESEARCH-CLINICAL ANAESTHESIOLOGY, 2006, 20 (01) :161-180
[12]   Antinociceptive monitors: tools or fools? [J].
Hoymork, S. C. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2008, 52 (08) :1035-1037
[13]   Assessment of surgical stress during general anaesthesia [J].
Huiku, M. ;
Uutela, K. ;
van Gils, M. ;
Korhonen, I. ;
Kymalainen, M. ;
Merilainen, P. ;
Paloheimo, M. ;
Rantanen, M. ;
Takala, P. ;
Viertio-Oja, H. ;
Yli-Hankala, A. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (04) :447-455
[14]   Skin vasomotor reflex as an objective indicator to assess the level of regional anesthesia [J].
Ikuta, Y ;
Shimoda, O ;
Ushijima, K ;
Terasaki, H .
ANESTHESIA AND ANALGESIA, 1998, 86 (02) :336-340
[15]   Measurement of surgical stress in anaesthetized children [J].
Kallio, H. ;
Lindberg, L. I. ;
Majander, A. S. ;
Uutela, K. H. ;
Niskanen, M. L. ;
Paloheimo, M. P. J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (03) :383-389
[16]   Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? [J].
Lu S. ;
Zhao H. ;
Ju K. ;
Shin K. ;
Lee M. ;
Shelley K. ;
Chon K.H. .
Journal of Clinical Monitoring and Computing, 2008, 22 (1) :23-29
[17]   Heart rate variability does not discriminate between different levels of haemodynamic responsiveness during surgical anaesthesia [J].
Luginbuehl, M. ;
Ypparila-Wolters, H. ;
Ruefenacht, M. ;
Petersen-Felix, S. ;
Korhonen, I. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (06) :728-736
[18]   Stimulation induced variability of pulse plethysmography does not discriminate responsiveness to intubation [J].
Luginbühl, M ;
Rüfenacht, M ;
Korhonen, I ;
Gils, M ;
Jakob, S ;
Petersen-Felix, S .
BRITISH JOURNAL OF ANAESTHESIA, 2006, 96 (03) :323-329
[19]   Prediction of the haemodynamic response to tracheal intubation:: comparison of laser-Doppler skin vasomotor reflex and pulse wave reflex [J].
Luginbühl, M ;
Reichlin, F ;
Sigurdsson, GH ;
Zbinden, AM ;
Petersen-Felix, S .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 89 (03) :389-397
[20]   The peripheral pulse wave: Information overlooked [J].
Murray, WB ;
Foster, PA .
JOURNAL OF CLINICAL MONITORING, 1996, 12 (05) :365-377