Photoplethysmography and nociception

被引:77
作者
Korhonen, I. [1 ,2 ]
Yli-Hankala, A. [2 ,3 ]
机构
[1] VTT Tech Res Ctr Finland, FIN-33101 Tampere, Finland
[2] Tampere Univ Hosp, Dept Anaesthesia, Tampere, Finland
[3] Univ Tampere, Sch Med, FIN-33101 Tampere, Finland
关键词
SKIN VASOMOTOR REFLEX; SURGICAL STRESS INDEX; PLETHYSMOGRAPHIC WAVE-FORM; MULTIPLE NOXIOUS STIMULI; GENERAL-ANESTHESIA; HEART-RATE; ISOFLURANE/OXYGEN ANESTHESIA; HEMODYNAMIC-RESPONSES; BLOOD-VOLUME; PULSE-WAVE;
D O I
10.1111/j.1399-6576.2009.02026.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Photoplethysmography (PPG), i.e. pulse oximetric wave, is a non-invasive technique that is used in anaesthesia monitoring primarily to monitor blood oxygenation. The PPG waveform resembles that of the arterial blood pressure but instead of pressure it is related to the volume changes in the measurement site and hence contains information related to the peripheral blood circulation, including skin vasomotion, which is controlled by the sympathetic nervous system. Because of this link, skin vasomotor response and PPG amplitude response have been associated with nociception under general anaesthesia. Recently, there has been interest in monitoring nociception during general anaesthesia. In many of the published studies, PPG waveform information has been included. The focus of this topical review is to provide an overview on the information embedded in the PPG waveform especially in the context of the autonomic nervous system and analgesia monitoring.
引用
收藏
页码:975 / 985
页数:11
相关论文
共 42 条
[1]   Surgical stress index reflects surgical stress in gynaecological laparoscopic day-case surgery [J].
Ahonen, J. ;
Jokela, R. ;
Uutela, K. ;
Huiku, M. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (04) :456-461
[2]   Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toes [J].
Allen, J ;
Murray, A .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2000, 147 (06) :403-407
[3]  
ALLEN J, 2000, IEE C PUBLICATION, V476, P26
[4]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[5]   The relationship between the photoplethysmographic waveform and systemic vascular resistance [J].
Awad A.A. ;
Haddadin A.S. ;
Tantawy H. ;
Badr T.M. ;
Stout R.G. ;
Silverman D.G. ;
Shelley K.H. .
Journal of Clinical Monitoring and Computing, 2007, 21 (6) :365-372
[6]   Photoplethysmographic measurement of changes in total and pulsatile tissue blood volume, following sympathetic blockade [J].
Babchenko, A ;
Davidson, E ;
Ginosar, Y ;
Kurz, V ;
Faib, I ;
Adler, D ;
Nitzan, M .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (02) :389-396
[7]   Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre [J].
Cannesson, M. ;
Desebbe, O. ;
Rosamel, P. ;
Delannoy, B. ;
Robin, J. ;
Bastien, O. ;
Lehot, J. -J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) :200-206
[8]   PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANESTHESIA - APPLICATION AND INTERPRETATION [J].
DORLAS, JC ;
NIJBOER, JA .
BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (05) :524-530
[9]   Sympathovagal balance - A critical appraisal [J].
Eckberg, DL .
CIRCULATION, 1997, 96 (09) :3224-3232
[10]   The effect of remifentanil on the bispectral index change and hemodynamic responses after orotracheal intubation [J].
Guignard, B ;
Menigaux, C ;
Dupont, X ;
Fletcher, D ;
Chauvin, M .
ANESTHESIA AND ANALGESIA, 2000, 90 (01) :161-167